master:Cable_CoaxSimpl parametersPSCAD Simplified Cable Cross-Section

Every parameter of the PSCAD Simplified Cable Cross-Section (master:Cable_CoaxSimpl): 61 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().

What master:Cable_CoaxSimpl is

Simplified Cable Cross-Section (Simplified Underground Cable), a component of PSCAD's Master Library, filed under passive branches, loads and filters.

Definition
master:Cable_CoaxSimpl
PSCAD name
Simplified Cable Cross-Section
Category
Passive branches, loads and filters
Parameters
61, in 5 groups; 27 carry a unit
Read from
PSCAD 5.0.0, 2026-11-07

Read and write master:Cable_CoaxSimpl in Python

import mhi.pscad

pscad = mhi.pscad.connect()              # the PSCAD that is open; launch() starts one
project = pscad.project("my_case")       # a case loaded in the workspace

for comp in project.find_all("master:Cable_CoaxSimpl"):   # the exact definition, namespace first
    params = comp.parameters()           # every parameter, as PSCAD holds it
    print(str(params["CI1"]))            # Capacitance, in uF/km

comp = project.find_all("master:Cable_CoaxSimpl")[0]
comp.parameters(CI1="0.6 [uF/km]")       # a value that carries a unit is written with it
  • A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
  • A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
  • A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
  • find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.

The Builder's runtime does the same with the unit handled for you: px_get(comp, "CI1") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.

Temperature Dependency

ParameterUnitDefaultDescription
ALAReal·0.00403ArmourEnter temperture coefficient in K^-1Range 0 to 100
ALCReal·0.00393ConductorEnter temperture coefficient in K^-1Range 0 to 100
ALSReal·0.00403SheathEnter temperture coefficient in K^-1Range 0 to 100
OPAReal·90.0ArmourEnter operating temperature in CelciusRange 0 to 1000
OPCReal·90.0ConductorEnter operating temperature in CelciusRange 0 to 1000
OPSReal·90.0SheathEnter operating temperature in CelciusRange 0 to 1000
TDChoice·DISABLETemperature Correction for Conductor ResistancesR(t) = R(t0)*(1+alpha*(t-t0))Written as DISABLE (Disable), ENABLE (Enable)
TE1Real·20.0Reference TemperatureEnter temperature at which resistance is defined in CelciusRange 0 to 200

Configuration

ParameterUnitDefaultDescription
CABNUMChoice·1Cable Number (First for Multiple Cables)Enter a number for this cable. This number must be between 1 and 12, and is used by the program to determine overall conductor numbering.Written as 1 = 1, 2 = 2, 3 = 3, 4 = 4, 5 = 5, 6 = 6, 7 = 7, 8 = 8, 9 = 9, 10 = 10, 11 = 11, 12 = 12
DRealm0.5Distance Between Adjacent CablesRange 0 to 100
GROUPNOChoice·1Cross-bonding GroupEnter the group number to which this cable belongs.Written as 1 = 1, 2 = 2, 3 = 3, 4 = 4
LLChoice·C1_I1_C2_I2Cable LayersSelect the configuration of the cable layers. C and I represent conducting and insulating layer respectively.Written as C1, C1_I1 (C1 | I1), C1_I1_C2 (C1 | I1 | C2), C1_I1_C2_I2 (C1 | I1 | C2 | I2), C1_I1_C2_I2_C3 (C1 | I1 | C2 | I2 | C3), C1_I1_C2_I2_C3_I3 (C1 | I1 | C2 | I2 | C3 | I3)
NCChoice·SINGLECable ConfigurationWritten as SINGLE (Single), FLAT (Three Cables (flat)), TREFOIL (Three Cables (trefoil)), TREFOILTOUCHING (Three Cables (trefoil-touching)), TWO_CABLES (Two Cables)
NameText··Name for IdentificationEnter a name for identification
TSHChoice·DISABLECross-bonding or Conductor EliminationWritten as DISABLE (Disable), ELIMINATE_OUTERMOST_CONDUCTING_LAYER (Eliminate outermost conducting layer), ELIMINATE_ALL_OUTER_CONDUCTING_LAYERS (Eliminate all outer conducting layers), ENABLE_IDEAL_CROSSBONDING (Enable ideal cross-bonding)Used when (LL>=3)
XRealm0.0Horizontal Translation From CentreEnter the translation of the cable centre-point along the horizontal (x) axis [m]. This value is relative to a local x=0 point, which is derived given the position of all cables in this segment.Range -1E+38 to 1E+38
YRealm1.0Depth Below Ground SurfaceEnter the depth of the cable centre-point below the earth surface [m].Range 1E-38 to 1E+38

Material Properties

ParameterUnitDefaultDescription
CI1RealuF/km0.3CapacitanceEnter the capacitance of the insulation [uF/km]Range 1E-38 to 10000
CI2RealuF/km1.0CapacitanceEnter the capacitance of the insulation [uF/km]Range 1E-38 to 10000
CI3RealuF/km1.0CapacitanceEnter the capacitance of the insulation [uF/km]Range 1E-38 to 10000
DCRARealohm/km0.046Dc ResistanceEnter the dc resistance of this conductor per unit length [ohm/km]Range 1E-38 to 100
DCRCRealohm/km0.046Dc ResistanceEnter the dc resistance of this conductor per unit length [ohm/km]Range 1E-38 to 100
DCRSRealohm/km0.046Dc ResistanceEnter the dc resistance of this conductor per unit length [ohm/km]Range 1E-38 to 100
DTAChoice·DC_RESISTANCEConductor Property Given asWritten as DC_RESISTANCE (Dc resistance), RESISTIVITY (Resistivity), 1724E8_OHM_M (Resistivity of copper (1.724e-8 ohm*m)), 2826E8_OHM_M (Resistivity of aluminum (2.826e-8 ohm*m)), 138E8_OHM_M (Resistivity of steel (13.8e-8 ohm*m)), 214E8_OHM_M (Resistivity of lead (21.4e-8 ohm*m)), 35E8_OHM_M (Resistivity of bronze (3.5e-8 ohm*m))
DTCChoice·DC_RESISTANCEConductor Property Given asWritten as DC_RESISTANCE (Dc resistance), RESISTIVITY (Resistivity), 1724E8_OHM_M (Resistivity of copper (1.724e-8 ohm*m)), 2826E8_OHM_M (Resistivity of aluminum (2.826e-8 ohm*m)), 138E8_OHM_M (Resistivity of steel (13.8e-8 ohm*m)), 214E8_OHM_M (Resistivity of lead (21.4e-8 ohm*m)), 35E8_OHM_M (Resistivity of bronze (3.5e-8 ohm*m))
DTI1Choice·CAPACITANCEInsulation Property Given asWritten as CAPACITANCE (Capacitance), RELATIVE_PERMITTIVITY (Relative permittivity), 25 (Relative permittivity of XLPE (2.5)), 80 (Relative permittivity of PVC (8.0)), 30 (Relative permittivity of EPR (3.0)), 36 (Relative permittivity of impregnated paper (3.6)), 23 (Relative permittivity of PE (2.3))
DTI2Choice·RELATIVE_PERMITTIVITYInsulation Property Given asWritten as CAPACITANCE (Capacitance), RELATIVE_PERMITTIVITY (Relative permittivity), 25 (Relative permittivity of XLPE (2.5)), 80 (Relative permittivity of PVC (8.0)), 30 (Relative permittivity of EPR (3.0)), 36 (Relative permittivity of impregnated paper (3.6)), 23 (Relative permittivity of PE (2.3))
DTI3Choice·RELATIVE_PERMITTIVITYInsulation Property Given asWritten as CAPACITANCE (Capacitance), RELATIVE_PERMITTIVITY (Relative permittivity), 25 (Relative permittivity of XLPE (2.5)), 80 (Relative permittivity of PVC (8.0)), 30 (Relative permittivity of EPR (3.0)), 36 (Relative permittivity of impregnated paper (3.6)), 23 (Relative permittivity of PE (2.3))
DTSChoice·DC_RESISTANCEConductor Property Given asWritten as DC_RESISTANCE (Dc resistance), RESISTIVITY (Resistivity), 1724E8_OHM_M (Resistivity of copper (1.724e-8 ohm*m)), 2826E8_OHM_M (Resistivity of aluminum (2.826e-8 ohm*m)), 138E8_OHM_M (Resistivity of steel (13.8e-8 ohm*m)), 214E8_OHM_M (Resistivity of lead (21.4e-8 ohm*m)), 35E8_OHM_M (Resistivity of bronze (3.5e-8 ohm*m))
EPS1Real·2.3Relative PermittivityEnter the relative permittivity of this insulator.Range 1E-38 to 100
EPS2Real·2.3Relative PermittivityEnter the relative permittivity of this insulator.Range 1E-38 to 100
EPS3Real·2.3Relative PermittivityEnter the relative permittivity of this insulator.Range 1E-38 to 100
LT1Real·0.0001Loss TangentEnter the loss tangent of this insulator.Range 0.0 to 10
LT2Real·0.0001Loss TangentEnter the loss tangent of this insulator.Range 0.0 to 10
LT3Real·0.0001Loss TangentEnter the loss tangent of this insulator.Range 0.0 to 10
RHOARealohm*m1.68e-8ResistivityEnter the resistivity of this conductor [ohm*m]Range 1E-38 to 100
RHOCRealohm*m1.68e-8ResistivityEnter the resistivity of this conductor [ohm*m]Range 1E-38 to 100
RHOSRealohm*m1.68e-8ResistivityEnter the resistivity of this conductor [ohm*m]Range 1E-38 to 100

Additional Material Properties

ParameterUnitDefaultDescription
FLTRealHz60.0Loss Tangent is Defined atEnter the frequency at which loss tangents are defined [Hz].Range 1e-6 to 1000
PERMAReal·1.0ArmourRange 1E-38 to 500
PERMCReal·1.0ConductorRange 1E-38 to 500
PERMSReal·1.0SheathRange 1E-38 to 500
SL1Realm0.001Inner Semi-conductor Layer ThicknessEnter the thickness of the inner semi-conducting layer (between insulator and conductor) [m].Range 1E-38 to 1E+38
SL2Realm0.001Outer Semi-conductor Layer ThicknessEnter the thickness of the inner semi-conducting layer (between insulator and sheath) [m].Range 1E-38 to 1E+38
SemiCLChoice·ABSENTSemi-conducting LayersWritten as ABSENT (Absent), PRESENT (Present)
mu_r1Real·1.0Insulator 1At least 0
mu_r2Real·1.0Insulator 2At least 0
mu_r3Real·1.0Insulator 3At least 0

Cable Dimensions

ParameterUnitDefaultDescription
R1Realm0.0Conductor Inner Radius (Enter 0.0 for a Solid Core):Enter the inner radius of the centre or core conductor [m]. If this conductor is solid (i.e. not hollow), then enter 0.0.Range 0 to 1E+38
R2Realm0.022Conductor Outer RadiusEnter the outer radius of the centre or core conductor [m].Range 1E-38 to 1E+38
R3Realm0.03951st Insulating LayerEnter the outer radius of this insulator [m].Range 1E-38 to 1E+38
R4Realm0.044SheathEnter the outer radius of this conducting layer [m].Range 1E-38 to 1E+38
R5Realm0.04752nd Insulating LayerEnter the outer radius of this insulator [m].Range 1E-38 to 1E+38
R6Realm0.0583ArmourEnter the outer radius of this conducting layer [m].Range 1E-38 to 1E+38
R7Realm0.06353rd Insulating LayerEnter the outer radius of this insulator [m].Range 1E-38 to 1E+38
RorTChoice·RADIAL_FROM_CENTRELayer Thickness is Specified asSelect the manner in which the layer thicknesses are specified. If radial from centre is selected, enter the distance from the centre-point to the outer radius of the layer.Written as RADIAL_FROM_CENTRE (Radial from centre), ACTUAL_THICKNESS (Actual thickness)
T3Realm0.01751st Insulating LayerEnter the thickness of this insulator [m].Range 1E-38 to 1E+38
T4Realm0.0045SheathEnter the thickness of this conducting layer [m].Range 1E-38 to 1E+38
T5Realm0.00352nd Insulating LayerEnter the thickness of this insulator [m].Range 1E-38 to 1E+38
T6Realm0.0065ArmourEnter the thickness of this conducting layer [m].Range 1E-38 to 1E+38
T7Realm0.00523rd Insulating LayerEnter the thickness of this insulator [m].Range 1E-38 to 1E+38