master:complex parametersPSCAD Second Order Complex Pole

Every parameter of the PSCAD Second Order Complex Pole (master:complex): 6 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().

What master:complex is

Second Order Complex Pole, a component of PSCAD's Master Library, filed under control blocks.

Definition
master:complex
PSCAD name
Second Order Complex Pole
Category
Control blocks
Parameters
6, in 1 group; 1 carry a unit
Read from
PSCAD 5.0.0, 2026-11-07

Read and write master:complex in Python

import mhi.pscad

pscad = mhi.pscad.connect()              # the PSCAD that is open; launch() starts one
project = pscad.project("my_case")       # a case loaded in the workspace

for comp in project.find_all("master:complex"):   # the exact definition, namespace first
    params = comp.parameters()           # every parameter, as PSCAD holds it
    print(str(params["Fo"]))             # Characteristic Frequency, in Hz

comp = project.find_all("master:complex")[0]
comp.parameters(Fo="0.002 [Hz]")         # a value that carries a unit is written with it
  • A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
  • A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
  • A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
  • find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.

The Builder's runtime does the same with the unit handled for you: px_get(comp, "Fo") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.

Configuration

ParameterUnitDefaultDescription
DimInteger·1DimensionRange 1 to 2147483647
FoRealHz0.001Characteristic FrequencyAt least 1E-307
GReal·1.0Gain
NameText··Name for IdentificationEnter a name for identification
TypeChoice·1_LOW_PASSFunction CodeSelect the pole typeWritten as 1_LOW_PASS (1 - Low Pass), 2_MID_PASS (2 - Mid Pass), 3_HIGH_PASS (3 - High Pass), 4_HIGH_REJECT (4 - High Reject), 5_MID_REJECT (5 - Mid Reject), 6_LOW_REJECT (6 - Low Reject), 7_HIGH_REJECT (7 - High Reject), 8_MID_REJECT (8 - Mid Reject), 9_LOW_REJECT (9 - Low Reject)
zReal·0.01Damping RatioRange -1 to 1

Related