master:l2g_imp parametersPSCAD Line to Ground Impedance
Every parameter of the PSCAD Line to Ground Impedance (master:l2g_imp): 7 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().
What master:l2g_imp is
Line to Ground Impedance, a component of PSCAD's Master Library, filed under passive branches, loads and filters.
- Definition
master:l2g_imp- PSCAD name
- Line to Ground Impedance
- Category
- Passive branches, loads and filters
- Parameters
- 7, in 2 groups; 4 carry a unit
- Read from
- PSCAD 5.0.0, 2026-11-07
Read and write master:l2g_imp in Python
import mhi.pscad
pscad = mhi.pscad.connect() # the PSCAD that is open; launch() starts one
project = pscad.project("my_case") # a case loaded in the workspace
for comp in project.find_all("master:l2g_imp"): # the exact definition, namespace first
params = comp.parameters() # every parameter, as PSCAD holds it
print(str(params["ConstKa"])) # K Constant Angle for Ground Impedance, in deg
comp = project.find_all("master:l2g_imp")[0]
comp.parameters(ConstKa="1 [deg]") # a value that carries a unit is written with it
- A parameter is named exactly as in the table, letter case included:
parameters()gives every one of them in a dictionary, and a name the component does not have is refused. - A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (
str(...)) or the unit is lost. PSCAD keeps a written unit as it is given:"2500 [mohm]"stays in mohm. - A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
find_all()takes the exact definition only. A wildcard or a bare name withoutmaster:comes back empty; the Builder'spx_findwalks the pages for those.
The Builder's runtime does the same with the unit handled for you: px_get(comp, "ConstKa") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.
Main Data
| Parameter | Unit | Default | Description |
|---|---|---|---|
AngTypChoice | · | RADIANS | Input Phase Angles are Given inSelet Radians or DegreesWritten as RADIANS (Radians), DEGREES (Degrees) |
ConstKReal | · | 1.2 | K Constant Magnitude for Ground ImpedanceAt least 0 |
ConstKaReal | deg | 0.0 | K Constant Angle for Ground ImpedanceRange -360 to 360 |
NameText | · | · | Name for IdentificationEnter a name for identification |
Initialization
| Parameter | Unit | Default | Description |
|---|---|---|---|
HoldTReal | s | 0.02 | Initialization TimeAt least 0 |
RIReal | ohm | 1.0E6 | Output R During Initilaization |
XIReal | ohm | 1.0E6 | Output X During Initilaization |
Related
← master:inductor Inductor · master:Line_Ground Line|Cable Ground Properties →