master:nodelabel parametersPSCAD Electrical Node Label

Every parameter of the PSCAD Electrical Node Label (master:nodelabel): 5 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().

What master:nodelabel is

Electrical Node Label (Electrical node label), a component of PSCAD's Master Library, filed under other components.

Definition
master:nodelabel
PSCAD name
Electrical Node Label
Category
Other components
Parameters
5, in 1 group; 1 carry a unit
Read from
PSCAD 5.0.0, 2026-11-07

Read and write master:nodelabel in Python

import mhi.pscad

pscad = mhi.pscad.connect()              # the PSCAD that is open; launch() starts one
project = pscad.project("my_case")       # a case loaded in the workspace

for comp in project.find_all("master:nodelabel"):   # the exact definition, namespace first
    params = comp.parameters()           # every parameter, as PSCAD holds it
    print(str(params["VBase"]))          # Base Voltage (L-G) for Normalizing, in kV

comp = project.find_all("master:nodelabel")[0]
comp.parameters(VBase="2 [kV]")          # a value that carries a unit is written with it
  • A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
  • A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
  • A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
  • find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.

The Builder's runtime does the same with the unit handled for you: px_get(comp, "VBase") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.

Configuration

ParameterUnitDefaultDescription
MeasVChoice·NOMeasure Voltage and Create Local Signal?Written as NO (No), YES (Yes)
NameText·NodeElectrical Node Name
PUChoice·NONormalize Measured Voltage?Select Yes or NoWritten as NO (No), YES (Yes)Used when (MeasV==1)
VBaseRealkV1Base Voltage (L-G) for NormalizingAt least 1E-307Used when (MeasV==1) && (PU==1)
VNameText·VNodeVoltage Signal NameUsed when (MeasV==1)

Related

← master:mesgam Effective Gamma · master:xnode External Electrical Node →