master:nodelabel parametersPSCAD Electrical Node Label
Every parameter of the PSCAD Electrical Node Label (master:nodelabel): 5 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().
What master:nodelabel is
Electrical Node Label (Electrical node label), a component of PSCAD's Master Library, filed under other components.
- Definition
master:nodelabel- PSCAD name
- Electrical Node Label
- Category
- Other components
- Parameters
- 5, in 1 group; 1 carry a unit
- Read from
- PSCAD 5.0.0, 2026-11-07
Read and write master:nodelabel in Python
import mhi.pscad
pscad = mhi.pscad.connect() # the PSCAD that is open; launch() starts one
project = pscad.project("my_case") # a case loaded in the workspace
for comp in project.find_all("master:nodelabel"): # the exact definition, namespace first
params = comp.parameters() # every parameter, as PSCAD holds it
print(str(params["VBase"])) # Base Voltage (L-G) for Normalizing, in kV
comp = project.find_all("master:nodelabel")[0]
comp.parameters(VBase="2 [kV]") # a value that carries a unit is written with it
- A parameter is named exactly as in the table, letter case included:
parameters()gives every one of them in a dictionary, and a name the component does not have is refused. - A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (
str(...)) or the unit is lost. PSCAD keeps a written unit as it is given:"2500 [mohm]"stays in mohm. - A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
find_all()takes the exact definition only. A wildcard or a bare name withoutmaster:comes back empty; the Builder'spx_findwalks the pages for those.
The Builder's runtime does the same with the unit handled for you: px_get(comp, "VBase") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.
Configuration
| Parameter | Unit | Default | Description |
|---|---|---|---|
MeasVChoice | · | NO | Measure Voltage and Create Local Signal?Written as NO (No), YES (Yes) |
NameText | · | Node | Electrical Node Name |
PUChoice | · | NO | Normalize Measured Voltage?Select Yes or NoWritten as NO (No), YES (Yes)Used when (MeasV==1) |
VBaseReal | kV | 1 | Base Voltage (L-G) for NormalizingAt least 1E-307Used when (MeasV==1) && (PU==1) |
VNameText | · | VNode | Voltage Signal NameUsed when (MeasV==1) |
Related
← master:mesgam Effective Gamma · master:xnode External Electrical Node →