master:power parametersPSCAD Real/Reactive Power Meter

Every parameter of the PSCAD Real/Reactive Power Meter (master:power): 6 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().

What master:power is

Real/Reactive Power Meter, a component of PSCAD's Master Library, filed under meters and output.

Definition
master:power
PSCAD name
Real/Reactive Power Meter
Category
Meters and output
Parameters
6, in 1 group; 1 carry a unit
Read from
PSCAD 5.0.0, 2026-11-07

Read and write master:power in Python

import mhi.pscad

pscad = mhi.pscad.connect()              # the PSCAD that is open; launch() starts one
project = pscad.project("my_case")       # a case loaded in the workspace

for comp in project.find_all("master:power"):   # the exact definition, namespace first
    params = comp.parameters()           # every parameter, as PSCAD holds it
    print(str(params["TS"]))             # Smoothing Time Constant, in s

comp = project.find_all("master:power")[0]
comp.parameters(TS="0.04 [s]")           # a value that carries a unit is written with it
  • A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
  • A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
  • A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
  • find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.

The Builder's runtime does the same with the unit handled for you: px_get(comp, "TS") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.

Configuration

ParameterUnitDefaultDescription
DIRChoice·OUT_OFPower MeasuredWritten as INTO (INTO_A), OUT_OF (OUT_OF_A)
NameText··Name for IdentificationEnter a name for identification
PChoice·YESMonitor Real Power?Written as NO (No), YES (Yes)
QChoice·YESMonitor Reactive Power?Written as NO (No), YES (Yes)
TSReals0.02Smoothing Time ConstantAt least 0
ViewChoice·SINGLE_LINEConnected to Node loops withWritten as 3_PHASE (3 phase view), SINGLE_LINE (Single line view)

Related