master:pwm_hcc parametersPSCAD Hysteresis Current Control PWM

Every parameter of the PSCAD Hysteresis Current Control PWM (master:pwm_hcc): 5 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().

What master:pwm_hcc is

Hysteresis Current Control PWM (PWM Generator (Hysteresis Current Control)), a component of PSCAD's Master Library, filed under control blocks.

Definition
master:pwm_hcc
PSCAD name
Hysteresis Current Control PWM
Category
Control blocks
Parameters
5, in 1 group; 2 carry a unit
Read from
PSCAD 5.0.0, 2026-11-07

Read and write master:pwm_hcc in Python

import mhi.pscad

pscad = mhi.pscad.connect()              # the PSCAD that is open; launch() starts one
project = pscad.project("my_case")       # a case loaded in the workspace

for comp in project.find_all("master:pwm_hcc"):   # the exact definition, namespace first
    params = comp.parameters()           # every parameter, as PSCAD holds it
    print(str(params["HN"]))             # Negative Saturation Limit, in kA

comp = project.find_all("master:pwm_hcc")[0]
comp.parameters(HN="0.02 [kA]")          # a value that carries a unit is written with it
  • A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
  • A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
  • A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
  • find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.

The Builder's runtime does the same with the unit handled for you: px_get(comp, "HN") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.

Configuration

ParameterUnitDefaultDescription
HNRealkA0.01Negative Saturation LimitEnter a value greater than zeroAt least 0
HPRealkA0.01Positive Saturation LimitEnter a value greater than zeroAt least 0
IDIRChoice·TOWARDSPhase Current DirectionSelect Direction of Current: Towards or Away from ConverterWritten as TOWARDS (Towards Converter), AWAY_FROM (Away from Converter)
INTERPChoice·ENABLEDInterpolation CompatibilitySelect Enable or DisableWritten as ENABLED (Enabled), DISABLED (Disabled)
NameText··Name for IdentificationEnter a name for identification

Related

← master:buffer Hysteresis Buffer · master:hysteresis_reactor Hysteresis Reactor →