master:recorder2_0 parametersPSCAD RTP and COMTRADE Recorder

Every parameter of the PSCAD RTP and COMTRADE Recorder (master:recorder2_0): 164 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().

What master:recorder2_0 is

RTP and COMTRADE Recorder (RTP and COMTRADE recorder), a component of PSCAD's Master Library, filed under control blocks.

Definition
master:recorder2_0
PSCAD name
RTP and COMTRADE Recorder
Category
Control blocks
Parameters
164, in 18 groups
Read from
PSCAD 5.0.0, 2026-11-07

Read and write master:recorder2_0 in Python

import mhi.pscad

pscad = mhi.pscad.connect()              # the PSCAD that is open; launch() starts one
project = pscad.project("my_case")       # a case loaded in the workspace

for comp in project.find_all("master:recorder2_0"):   # the exact definition, namespace first
    params = comp.parameters()           # every parameter, as PSCAD holds it
    print(str(params["AMax"]))           # Analogue Output Maximum

comp = project.find_all("master:recorder2_0")[0]
comp.parameters(AMax="8192")             # written as text
  • A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
  • A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
  • A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
  • find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.

The Builder's runtime does the same with the unit handled for you: px_get(comp, "AMax") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.

Main Configuration

ParameterUnitDefaultDescription
AMaxIntegerยท4096Analogue Output MaximumUsed only in COMTRADE format output files, output will be scaled so that miaximum number corresponds to what is specified hereRange 0 to 32767Used when ((FFMT>0))
AMinIntegerยท0Analogue Output MinimumUsed only in COMTRADE format output files, output will be scaled so that minimum number corresponds to what is specified hereRange -32768 to 0Used when ((FFMT>0))
DevNoIntegerยท1Recorder Device NumberEnter a number for identificaton purposeRange 1 to 99
ENTCAPChoiceยทNOCapture Trigger TimeSelect Yes or NoWritten as NO (No), YES (Yes)Used when (FFMT>0)
FFMTChoiceยทRTPOutput File FormatSelect from RTP, COMTRADE 91 or COMTRADE 99 output formatsWritten as RTP, COMTRADE_91 (Comtrade 91), COMTRADE_99 (Comtrade 99)
FNameTextยทplaybackOutput File NameOutput filename with no extension, length is limited for 8 characters for COMTRADE standard compatibility
FREQChoiceยท50_HZSystem FrequencySelect system frequency 50Hz or 60HzWritten as 50_HZ (50 Hz), 60_HZ (60 Hz)
MFILEChoiceยทSINGLEOutput FilesSelect single or multiple, used only for COMTRADE format output filesWritten as SINGLE (single), MULTIPLE (multiple)Used when ((FFMT>0))
MfilterChoiceยทNEVERLow Pass Filtering EnableSelect Rstep>Tstep to enable low pass filtering when recording timestep is larger than simulaton timestepWritten as NEVER (never), RSTEP_TSTEP (Rstep>Tstep)
NChAIntegerยท2Number of 16-bit Analog ChannelsEnter the number of analog input channels to be recordedRange 1 to 12
NChDIntegerยท0Number of Digital ChannelsEnter the number of digital input channels to be recordedRange 0 to 16
NameTextยทยทName for IdentificationEnter a name for identification
NxHdrChoiceยท0Number of Extra Header File LinesSelect the number of lines to be added to the COMTRADE header fileWritten as 0 = 0, 1 = 1, 2 = 2, 3 = 3, 4 = 4, 5 = 5Used when FFMT>0
RstepIntegerยท50Recording Time Step (microseconds)Enter recording timestep, if less than simulation timestep simulation timestep would be usedRange 1 to 1200
StnNTextยทEMTDC_SimulationStation NameEnter a descriptive station name, required for COMTRADE output files

Analog Channel A1

ParameterUnitDefaultDescription
CT1TextยทA1A1 Component Being Monitored (Comtrade)Enter the component being monitored, this will be written in the COMTRADE configuration fileUsed when (FFMT>0)
DA1TextยทA1A1 Variable Description (Comtrade)Enter the variable description to be used in the COMTRADE configuration fileUsed when (FFMT>0)
NA1TextยทA1A1 Analog Variable Name
PH1Choiceยท0A1 Phase IdentificationSelect phases A,B,C or N, used in COMTRADE onlyWritten as B, C, N, Used when (FFMT>0)
TR1Realยท1.0A1 PT or CT RatioEnter CT/PT ratio, note primary signals are in kV and kARange 1E-20 to 1E+20
UN1TextยทA1A1 _Other_ UnitEnter the unit if the variable is not current or voltageUsed when ((VT1==2))
VS1ChoiceยทPRIMARYA1 Variable SourceSelect Primary or Secondary source, if Primary is selected the output will be scaled by the PT/CT ratioWritten as PRIMARY (Primary), SECONDARY (Secondary)
VT1ChoiceยทVOLTAGEA1 Variable TypeSelect Voltage, Current or OtherWritten as VOLTAGE (Voltage), CURRENT (Current), OTHER (Other)

Analog Channel A10

ParameterUnitDefaultDescription
CT10TextยทA10A10 Component Being Monitored (Comtrade)Enter the component being monitored, this will be written in the COMTRADE configuration fileUsed when (FFMT>0)
DA10TextยทA10A10 Variable Description (Comtrade)Enter the variable description to be used in the COMTRADE configuration fileUsed when (FFMT>0)
NA10TextยทA10A10 Analog Variable Name
PH10Choiceยท0A10 Phase IdentificationSelect phases A,B,C or N, used in COMTRADE onlyWritten as B, C, N, Used when (FFMT>0)
TR10Realยท1.0A10 PT or CT RatioEnter CT/PT ratio, note primary signals are in kV and kARange 1E-20 to 1E+20Used when (NChA>9)
UN10TextยทA10A10 _Other_ UnitEnter the unit if the variable is not current or voltageUsed when ((VT10==2)&&(NChA>9))
VS10ChoiceยทPRIMARYA10 Variable SourceSelect Primary or Secondary source, if Primary is selected the output will be scaled by the PT/CT ratioWritten as PRIMARY (Primary), SECONDARY (Secondary)
VT10ChoiceยทVOLTAGEA10 Variable TypeSelect Voltage, Current or OtherWritten as VOLTAGE (Voltage), CURRENT (Current), OTHER (Other)

Analog Channel A11

ParameterUnitDefaultDescription
CT11TextยทA11A11 Component Being Monitored (Comtrade)Enter the component being monitored, this will be written in the COMTRADE configuration fileUsed when (FFMT>0)
DA11TextยทA11A11 Variable Description (Comtrade)Enter the variable description to be used in the COMTRADE configuration fileUsed when (FFMT>0)
NA11TextยทA11A11 Analog Variable Name
PH11Choiceยท0A11 Phase IdentificationSelect phases A,B,C or N, used in COMTRADE onlyWritten as B, C, N, Used when (FFMT>0)
TR11Realยท1.0A11 PT or CT RatioEnter CT/PT ratio, note primary signals are in kV and kARange 1E-20 to 1E+20Used when (NChA>10)
UN11TextยทA11A11 _Other_ UnitEnter the unit if the variable is not current or voltageUsed when ((VT11==2)&&(NChA>10))
VS11ChoiceยทPRIMARYA11 Variable SourceSelect Primary or Secondary source, if Primary is selected the output will be scaled by the PT/CT ratioWritten as PRIMARY (Primary), SECONDARY (Secondary)
VT11ChoiceยทVOLTAGEA11 Variable TypeSelect Voltage, Current or OtherWritten as VOLTAGE (Voltage), CURRENT (Current), OTHER (Other)

Analog Channel A12

ParameterUnitDefaultDescription
CT12TextยทA12A12 Component Being Monitored (Comtrade)Enter the component being monitored, this will be written in the COMTRADE configuration fileUsed when (FFMT>0)
DA12TextยทA12A12 Variable Description (Comtrade)Enter the variable description to be used in the COMTRADE configuration fileUsed when (FFMT>0)
NA12TextยทA12A12 Analog Variable Name
PH12Choiceยท0A12 Phase IdentificationSelect phases A,B,C or N, used in COMTRADE onlyWritten as B, C, N, Used when (FFMT>0)
TR12Realยท1.0A12 PT or CT RatioEnter CT/PT ratio, note primary signals are in kV and kARange 1E-20 to 1E+20Used when (NChA>11)
UN12TextยทA12A12 _Other_ UnitEnter the unit if the variable is not current or voltageUsed when ((VT12==2)&&(NChA>11))
VS12ChoiceยทPRIMARYA12 Variable SourceSelect Primary or Secondary source, if Primary is selected the output will be scaled by the PT/CT ratioWritten as PRIMARY (Primary), SECONDARY (Secondary)
VT12ChoiceยทVOLTAGEA12 Variable TypeSelect Voltage, Current or OtherWritten as VOLTAGE (Voltage), CURRENT (Current), OTHER (Other)

Analog Channel A2

ParameterUnitDefaultDescription
CT2TextยทA2A2 Component Being Monitored (Comtrade)Enter the component being monitored, this will be written in the COMTRADE configuration fileUsed when (FFMT>0)
DA2TextยทA2A2 Variable Description (Comtrade)Enter the variable description to be used in the COMTRADE configuration fileUsed when (FFMT>0)
NA2TextยทA2A2 Analog Variable Name
PH2Choiceยท0A2 Phase IdentificationSelect phases A,B,C or N, used in COMTRADE onlyWritten as B, C, N, Used when (FFMT>0)
TR2Realยท1.0A2 PT or CT RatioEnter CT/PT ratio, note primary signals are in kV and kARange 1E-20 to 1E+20Used when (NChA>1)
UN2TextยทA2A2 _Other_ UnitEnter the unit if the variable is not current or voltageUsed when ((VT2==2)&&(NChA>1))
VS2ChoiceยทPRIMARYA2 Variable SourceSelect Primary or Secondary source, if Primary is selected the output will be scaled by the PT/CT ratioWritten as PRIMARY (Primary), SECONDARY (Secondary)
VT2ChoiceยทVOLTAGEA2 Variable TypeSelect Voltage, Current or OtherWritten as VOLTAGE (Voltage), CURRENT (Current), OTHER (Other)

Analog Channel A3

ParameterUnitDefaultDescription
CT3TextยทA3A3 Component Being Monitored (Comtrade)Enter the component being monitored, this will be written in the COMTRADE configuration fileUsed when (FFMT>0)
DA3TextยทA3A3 Variable Description (Comtrade)Enter the variable description to be used in the COMTRADE configuration fileUsed when (FFMT>0)
NA3TextยทA3A3 Analog Variable Name
PH3Choiceยท0A3 Phase IdentificationSelect phases A,B,C or N, used in COMTRADE onlyWritten as B, C, N, Used when (FFMT>0)
TR3Realยท1.0A3 PT or CT RatioEnter CT/PT ratio, note primary signals are in kV and kARange 1E-20 to 1E+20Used when (NChA>2)
UN3TextยทA3A3 _Other_ UnitEnter the unit if the variable is not current or voltageUsed when ((VT3==2)&&(NChA>2))
VS3ChoiceยทPRIMARYA3 Variable SourceSelect Primary or Secondary source, if Primary is selected the output will be scaled by the PT/CT ratioWritten as PRIMARY (Primary), SECONDARY (Secondary)
VT3ChoiceยทVOLTAGEA3 Variable TypeSelect Voltage, Current or OtherWritten as VOLTAGE (Voltage), CURRENT (Current), OTHER (Other)

Analog Channel A4

ParameterUnitDefaultDescription
CT4TextยทA4A4 Component Being Monitored (Comtrade)Enter the component being monitored, this will be written in the COMTRADE configuration fileUsed when (FFMT>0)
DA4TextยทA4A4 Variable Description (Comtrade)Enter the variable description to be used in the COMTRADE configuration fileUsed when (FFMT>0)
NA4TextยทA4A4 Analog Variable Name
PH4Choiceยท0A4 Phase IdentificationSelect phases A,B,C or N, used in COMTRADE onlyWritten as B, C, N, Used when (FFMT>0)
TR4Realยท1.0A4 PT or CT RatioEnter CT/PT ratio, note primary signals are in kV and kARange 1E-20 to 1E+20Used when (NChA>3)
UN4TextยทA4A4 _Other_ UnitEnter the unit if the variable is not current or voltageUsed when ((VT4==2)&&(NChA>3))
VS4ChoiceยทPRIMARYA4 Variable SourceSelect Primary or Secondary source, if Primary is selected the output will be scaled by the PT/CT ratioWritten as PRIMARY (Primary), SECONDARY (Secondary)
VT4ChoiceยทVOLTAGEA4 Variable TypeSelect Voltage, Current or OtherWritten as VOLTAGE (Voltage), CURRENT (Current), OTHER (Other)

Analog Channel A5

ParameterUnitDefaultDescription
CT5TextยทA5A5 Component Being Monitored (Comtrade)Enter the component being monitored, this will be written in the COMTRADE configuration fileUsed when (FFMT>0)
DA5TextยทA5A5 Variable Description (Comtrade)Enter the variable description to be used in the COMTRADE configuration fileUsed when (FFMT>0)
NA5TextยทA5A5 Analog Variable Name
PH5Choiceยท0A5 Phase IdentificationSelect phases A,B,C or N, used in COMTRADE onlyWritten as B, C, N, Used when (FFMT>0)
TR5Realยท1.0A5 PT or CT RatioEnter CT/PT ratio, note primary signals are in kV and kARange 1E-20 to 1E+20Used when (NChA>4)
UN5TextยทA5A5 _Other_ UnitEnter the unit if the variable is not current or voltageUsed when ((VT5==2)&&(NChA>4))
VS5ChoiceยทPRIMARYA5 Variable SourceSelect Primary or Secondary source, if Primary is selected the output will be scaled by the PT/CT ratioWritten as PRIMARY (Primary), SECONDARY (Secondary)
VT5ChoiceยทVOLTAGEA5 Variable TypeSelect Voltage, Current or OtherWritten as VOLTAGE (Voltage), CURRENT (Current), OTHER (Other)

Analog Channel A6

ParameterUnitDefaultDescription
CT6TextยทA6A6 Component Being Monitored (Comtrade)Enter the component being monitored, this will be written in the COMTRADE configuration fileUsed when (FFMT>0)
DA6TextยทA6A6 Variable Description (Comtrade)Enter the variable description to be used in the COMTRADE configuration fileUsed when (FFMT>0)
NA6TextยทA6A6 Analog Variable Name
PH6Choiceยท0A6 Phase IdentificationSelect phases A,B,C or N, used in COMTRADE onlyWritten as B, C, N, Used when (FFMT>0)
TR6Realยท1.0A6 PT or CT RatioEnter CT/PT ratio, note primary signals are in kV and kARange 1E-20 to 1E+20Used when (NChA>5)
UN6TextยทA6A6 _Other_ UnitEnter the unit if the variable is not current or voltageUsed when ((VT6==2)&&(NChA>5))
VS6ChoiceยทPRIMARYA6 Variable SourceSelect Primary or Secondary source, if Primary is selected the output will be scaled by the PT/CT ratioWritten as PRIMARY (Primary), SECONDARY (Secondary)
VT6ChoiceยทVOLTAGEA6 Variable TypeSelect Voltage, Current or OtherWritten as VOLTAGE (Voltage), CURRENT (Current), OTHER (Other)

Analog Channel A7

ParameterUnitDefaultDescription
CT7TextยทA7A7 Component Being Monitored (Comtrade)Enter the component being monitored, this will be written in the COMTRADE configuration fileUsed when (FFMT>0)
DA7TextยทA7A7 Variable Description (Comtrade)Enter the variable description to be used in the COMTRADE configuration fileUsed when (FFMT>0)
NA7TextยทA7A7 Analog Variable Name
PH7Choiceยท0A7 Phase IdentificationSelect phases A,B,C or N, used in COMTRADE onlyWritten as B, C, N, Used when (FFMT>0)
TR7Realยท1.0A7 PT or CT RatioEnter CT/PT ratio, note primary signals are in kV and kARange 1E-20 to 1E+20Used when (NChA>6)
UN7TextยทA7A7 _Other_ UnitEnter the unit if the variable is not current or voltageUsed when ((VT7==2)&&(NChA>6))
VS7ChoiceยทPRIMARYA7 Variable SourceSelect Primary or Secondary source, if Primary is selected the output will be scaled by the PT/CT ratioWritten as PRIMARY (Primary), SECONDARY (Secondary)
VT7ChoiceยทVOLTAGEA7 Variable TypeSelect Voltage, Current or OtherWritten as VOLTAGE (Voltage), CURRENT (Current), OTHER (Other)

Analog Channel A8

ParameterUnitDefaultDescription
CT8TextยทA8A8 Component Being Monitored (Comtrade)Enter the component being monitored, this will be written in the COMTRADE configuration fileUsed when (FFMT>0)
DA8TextยทA8A8 Variable Description (Comtrade)Enter the variable description to be used in the COMTRADE configuration fileUsed when (FFMT>0)
NA8TextยทA8A8 Analog Variable Name
PH8Choiceยท0A8 Phase IdentificationSelect phases A,B,C or N, used in COMTRADE onlyWritten as B, C, N, Used when (FFMT>0)
TR8Realยท1.0A8 PT or CT RatioEnter CT/PT ratio, note primary signals are in kV and kARange 1E-20 to 1E+20Used when (NChA>7)
UN8TextยทA8A8 _Other_ UnitEnter the unit if the variable is not current or voltageUsed when ((VT8==2)&&(NChA>7))
VS8ChoiceยทPRIMARYA8 Variable SourceSelect Primary or Secondary source, if Primary is selected the output will be scaled by the PT/CT ratioWritten as PRIMARY (Primary), SECONDARY (Secondary)
VT8ChoiceยทVOLTAGEA8 Variable TypeSelect Voltage, Current or OtherWritten as VOLTAGE (Voltage), CURRENT (Current), OTHER (Other)

Analog Channel A9

ParameterUnitDefaultDescription
CT9TextยทA9A9 Component Being Monitored (Comtrade)Enter the component being monitored, this will be written in the COMTRADE configuration fileUsed when (FFMT>0)
DA9TextยทA9A9 Variable Description (Comtrade)Enter the variable description to be used in the COMTRADE configuration fileUsed when (FFMT>0)
NA9TextยทA9A9 Analog Variable Name
PH9Choiceยท0A9 Phase IdentificationSelect phases A,B,C or N, used in COMTRADE onlyWritten as B, C, N, Used when (FFMT>0)
TR9Realยท1.0A9 PT or CT RatioEnter CT/PT ratio, note primary signals are in kV and kARange 1E-20 to 1E+20Used when (NChA>8)
UN9TextยทA9A9 _Other_ UnitEnter the unit if the variable is not current or voltageUsed when ((VT9==2)&&(NChA>8))
VS9ChoiceยทPRIMARYA9 Variable SourceSelect Primary or Secondary source, if Primary is selected the output will be scaled by the PT/CT ratioWritten as PRIMARY (Primary), SECONDARY (Secondary)
VT9ChoiceยทVOLTAGEA9 Variable TypeSelect Voltage, Current or OtherWritten as VOLTAGE (Voltage), CURRENT (Current), OTHER (Other)

Digital Channels D1 - D4

ParameterUnitDefaultDescription
DD1TextยทD1D1 Variable DescriptionVariable description to be used in the COMTRADE configuration fileUsed when ((FFMT>0)&&(NCHD>=1))
DD2TextยทD2D2 Variable DescriptionVariable description to be used in the COMTRADE configuration fileUsed when ((FFMT>0)&&(NCHD>=2))
DD3TextยทD3D3 Variable DescriptionVariable description to be used in the COMTRADE configuration fileUsed when ((FFMT>0)&&(NCHD>=3))
DD4TextยทD4D4 Variable DescriptionVariable description to be used in the COMTRADE configuration fileUsed when ((FFMT>0)&&(NCHD>=4))
ND1TextยทD1D1 Status Variable NameDigital input variable nameUsed when (NCHD>=1)
ND2TextยทD2D2 Status Variable NameDigital input variable nameUsed when (NCHD>=2)
ND3TextยทD3D3 Status Variable NameDigital input variable nameUsed when (NCHD>=3)
ND4TextยทD4D4 Status Variable NameDigital input variable nameUsed when (NCHD>=4)
NT1Choiceยท0D1 Normal Operating StateSelect 0 or 1, default initial valueWritten as 0 = 0, 1 = 1Used when ((FFMT>0)&&(NCHD>=1))
NT2Choiceยท0D2 Normal Operating StateSelect 0 or 1, default initial valueWritten as 0 = 0, 1 = 1Used when ((FFMT>0)&&(NCHD>=2))
NT3Choiceยท0D3 Normal Operating StateSelect 0 or 1, default initial valueWritten as 0 = 0, 1 = 1Used when ((FFMT>0)&&(NCHD>=3))
NT4Choiceยท0D4 Normal Operating StateSelect 0 or 1, default initial valueWritten as 0 = 0, 1 = 1Used when ((FFMT>0)&&(NCHD>=4))

Digital Channels D9 - D12

ParameterUnitDefaultDescription
DD10TextยทD10D10 Variable DescriptionVariable description to be used in the COMTRADE configuration fileUsed when ((FFMT>0)&&(NCHD>=10))
DD11TextยทD11D11 Variable DescriptionVariable description to be used in the COMTRADE configuration fileUsed when ((FFMT>0)&&(NCHD>=11))
DD12TextยทD12D12 Variable DescriptionVariable description to be used in the COMTRADE configuration fileUsed when ((FFMT>0)&&(NCHD>=12))
DD9TextยทD9D9 Variable DescriptionVariable description to be used in the COMTRADE configuration fileUsed when ((FFMT>0)&&(NCHD>=9))
ND10TextยทD10D10 Status Variable NameDigital input variable nameUsed when (NCHD>=10)
ND11TextยทD11D11 Status Variable NameDigital input variable nameUsed when (NCHD>=11)
ND12TextยทD12D12 Status Variable NameDigital input variable nameUsed when (NCHD>=12)
ND9TextยทD9D9 Status Variable NameDigital input variable nameUsed when (NCHD>=9)
NT10Choiceยท0D10 Normal Operating StateSelect 0 or 1, default initial valueWritten as 0 = 0, 1 = 1Used when ((FFMT>0)&&(NCHD>=10))
NT11Choiceยท0D11 Normal Operating StateSelect 0 or 1, default initial valueWritten as 0 = 0, 1 = 1Used when ((FFMT>0)&&(NCHD>=11))
NT12Choiceยท0D12 Normal Operating StateSelect 0 or 1, default initial valueWritten as 0 = 0, 1 = 1Used when ((FFMT>0)&&(NCHD>=12))
NT9Choiceยท0D9 Normal Operating StateSelect 0 or 1, default initial valueWritten as 0 = 0, 1 = 1Used when ((FFMT>0)&&(NCHD>=9))

Digital Channels D13 - D16

ParameterUnitDefaultDescription
DD13TextยทD13D13 Variable DescriptionVariable description to be used in the COMTRADE configuration fileUsed when ((FFMT>0)&&(NCHD>=13))
DD14TextยทD14D14 Variable DescriptionVariable description to be used in the COMTRADE configuration fileUsed when ((FFMT>0)&&(NCHD>=14))
DD15TextยทD15D15 Variable DescriptionVariable description to be used in the COMTRADE configuration fileUsed when ((FFMT>0)&&(NCHD>=15))
DD16TextยทD16D16 Variable DescriptionVariable description to be used in the COMTRADE configuration fileUsed when ((FFMT>0)&&(NCHD>=16))
ND13TextยทD13D13 Status Variable NameDigital input variable nameUsed when (NCHD>=13)
ND14TextยทD14D14 Status Variable NameDigital input variable nameUsed when (NCHD>=14)
ND15TextยทD15D15 Status Variable NameDigital input variable nameUsed when (NCHD>=15)
ND16TextยทD16D16 Status Variable NameDigital input variable nameUsed when (NCHD>=16)
NT13Choiceยท0D13 Normal Operating StateSelect 0 or 1, default initial valueWritten as 0 = 0, 1 = 1Used when ((FFMT>0)&&(NCHD>=13))
NT14Choiceยท0D14 Normal Operating StateSelect 0 or 1, default initial valueWritten as 0 = 0, 1 = 1Used when ((FFMT>0)&&(NCHD>=14))
NT15Choiceยท0D15 Normal Operating StateSelect 0 or 1, default initial valueWritten as 0 = 0, 1 = 1Used when ((FFMT>0)&&(NCHD>=15))
NT16Choiceยท0D16 Normal Operating StateSelect 0 or 1, default initial valueWritten as 0 = 0, 1 = 1Used when ((FFMT>0)&&(NCHD>=16))

Digital Channels D5 - D8

ParameterUnitDefaultDescription
DD5TextยทD5D5 Variable DescriptionVariable description to be used in the COMTRADE configuration fileUsed when ((FFMT>0)&&(NCHD>=5))
DD6TextยทD6D6 Variable DescriptionVariable description to be used in the COMTRADE configuration fileUsed when ((FFMT>0)&&(NCHD>=6))
DD7TextยทD7D7 Variable DescriptionVariable description to be used in the COMTRADE configuration fileUsed when ((FFMT>0)&&(NCHD>=7))
DD8TextยทD8D8 Variable DescriptionVariable description to be used in the COMTRADE configuration fileUsed when ((FFMT>0)&&(NCHD>=8))
ND5TextยทD5D5 Status Variable NameDigital input variable nameUsed when (NCHD>=5)
ND6TextยทD6D6 Status Variable NameDigital input variable nameUsed when (NCHD>=6)
ND7TextยทD7D7 Status Variable NameDigital input variable nameUsed when (NCHD>=7)
ND8TextยทD8D8 Status Variable NameDigital input variable nameUsed when (NCHD>=8)
NT5Choiceยท0D5 Normal Operating StateSelect 0 or 1, default initial valueWritten as 0 = 0, 1 = 1Used when ((FFMT>0)&&(NCHD>=5))
NT6Choiceยท0D6 Normal Operating StateSelect 0 or 1, default initial valueWritten as 0 = 0, 1 = 1Used when ((FFMT>0)&&(NCHD>=6))
NT7Choiceยท0D7 Normal Operating StateSelect 0 or 1, default initial valueWritten as 0 = 0, 1 = 1Used when ((FFMT>0)&&(NCHD>=7))
NT8Choiceยท0D8 Normal Operating StateSelect 0 or 1, default initial valueWritten as 0 = 0, 1 = 1Used when ((FFMT>0)&&(NCHD>=8))

Comtrade Header File

ParameterUnitDefaultDescription
Hdr1TextยทExtra_Line_1Extra Header File Line 1Descriptive line to be added to the COMTRADE header fileUsed when (Nxhdr>0)
Hdr2TextยทExtra_Line_2Extra Header File Line 2Descriptive line to be added to the COMTRADE header fileUsed when (Nxhdr>1)
Hdr3TextยทExtra_Line_3Extra Header File Line 3Descriptive line to be added to the COMTRADE header fileUsed when (Nxhdr>2)
Hdr4TextยทExtra_Line_4Extra Header File Line 4Descriptive line to be added to the COMTRADE header fileUsed when (Nxhdr>3)
Hdr5TextยทExtra_Line_5Extra Header File Line 5Descriptive line to be added to the COMTRADE header fileUsed when (Nxhdr>4)

Related

โ† master:Zrealpole Real Pole ยท master:sandhdefn Sample and Hold โ†’