master:signalgen parametersPSCAD Signal Generator

Every parameter of the PSCAD Signal Generator (master:signalgen): 8 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().

What master:signalgen is

Signal Generator (Signal Generator /w Interpolation), a component of PSCAD's Master Library, filed under control blocks.

Definition
master:signalgen
PSCAD name
Signal Generator
Category
Control blocks
Parameters
8, in 1 group; 3 carry a unit
Read from
PSCAD 5.0.0, 2026-11-07

Read and write master:signalgen in Python

import mhi.pscad

pscad = mhi.pscad.connect()              # the PSCAD that is open; launch() starts one
project = pscad.project("my_case")       # a case loaded in the workspace

for comp in project.find_all("master:signalgen"):   # the exact definition, namespace first
    params = comp.parameters()           # every parameter, as PSCAD holds it
    print(str(params["Duty"]))           # Duty Cycle, in %

comp = project.find_all("master:signalgen")[0]
comp.parameters(Duty="100 [%]")          # a value that carries a unit is written with it
  • A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
  • A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
  • A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
  • find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.

The Builder's runtime does the same with the unit handled for you: px_get(comp, "Duty") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.

Configuration

ParameterUnitDefaultDescription
DutyReal%50Duty CycleRange 0 to 100
FRealHz60.0Frequency of SignalAt least 1E-307
INTRChoice·DISABLEDInterpolation CompatibilityWritten as DISABLED (Disabled), ENABLED (Enabled)Used when Type == 2
MaxReal·1.0Maximum Output Level
MinReal·0.0Minimum Output Level
NameText··Name for IdentificationEnter a name for identification
PRealdeg0.0Initial Phase of SignalRange -360 to 360
TypeChoice·TRIANGLESignal Type:Select Triangle or PulseWritten as TRIANGLE (Triangle), PULSE (Pulse)

Related