master:spim_uw parametersPSCAD Single Phase Induction Machine

Every parameter of the PSCAD Single Phase Induction Machine (master:spim_uw): 39 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().

What master:spim_uw is

Single Phase Induction Machine, a component of PSCAD's Master Library, filed under machines, exciters and governors.

Definition
master:spim_uw
PSCAD name
Single Phase Induction Machine
Category
Machines, exciters and governors
Parameters
39, in 4 groups; 32 carry a unit
Read from
PSCAD 5.0.0, 2026-11-07

Read and write master:spim_uw in Python

import mhi.pscad

pscad = mhi.pscad.connect()              # the PSCAD that is open; launch() starts one
project = pscad.project("my_case")       # a case loaded in the workspace

for comp in project.find_all("master:spim_uw"):   # the exact definition, namespace first
    params = comp.parameters()           # every parameter, as PSCAD holds it
    print(str(params["D"]))              # Mechanical Damping, in pu

comp = project.find_all("master:spim_uw")[0]
comp.parameters(D="1 [pu]")              # a value that carries a unit is written with it
  • A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
  • A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
  • A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
  • find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.

The Builder's runtime does the same with the unit handled for you: px_get(comp, "D") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.

Configuration

ParameterUnitDefaultDescription
DRealpu0.01 [pu]Mechanical DampingEnter the mechanical damping coefficientAt least 0Used when MM==0
JReals0.7267 [s]Angular Moment of Inertia (J=2H)Enter the moment of inertia of the machineAt least 0Used when MM==0
MMChoice·DISABLEDMultimass InterfaceSelect Enable or DisableWritten as DISABLED (Disabled), ENABLED (Enabled)
MsatChoice·DISABLEDMutual SaturationSelect Enable or DisableWritten as DISABLED (Disabled), ENABLED (Enabled)
NReal·1.0Stator Turns Ratio [auxiliary/main]Enter the turns ratio between auxcillary winding and the main windingAt least 0
NameText··Motor NameOptional: Enter a descriptive name if desiredRange 0 to 0
PBASERealMW0.01 [MW]Rated PowerEnter the rated power of the machineAt least 0
VBASERealkV0.1 [kV]Rated VoltageEnter the rated voltage of the machineAt least 0
freqRealHz60 [Hz]Rated FrequencyEnter the rated frequency of the machineAt least 0

Mutual Saturation Curve (I,V)

ParameterUnitDefaultDescription
I10MRealpu4.2 [pu]Point 10 - Magnetizing CurrentAt least 0
I1MRealpu0.0Point 1 - Magnetizing CurrentAt least 0Used when false
I2MRealpu0.5 [pu]Point 2 - Magnetizing CurrentAt least 0
I3MRealpu0.8 [pu]Point 3 - Magnetizing CurrentAt least 0
I4MRealpu1.0 [pu]Point 4 - Magnetizing CurrentAt least 0
I5MRealpu1.2 [pu]Point 5 - Magnetizing CurrentAt least 0
I6MRealpu1.5 [pu]Point 6 - Magnetizing CurrentAt least 0
I7MRealpu1.8 [pu]Point 7 - Magnetizing CurrentAt least 0
I8MRealpu2.2 [pu]Point 8 - Magnetizing CurrentAt least 0
I9MRealpu3.2 [pu]Point 9 - Magnetizing CurrentAt least 0
NpntsChoice·3Number of Points AvailableWritten as 3 = 3, 4 = 4, 5 = 5, 6 = 6, 7 = 7, 8 = 8, 9 = 9, 10 = 10
V10MRealpu1.5 [pu]Point 10 - Magnetizing VoltageAt least 0
V1MRealpu0.0Point 1 - Magnetizing VoltageAt least 0Used when false
V2MRealpu0.5 [pu]Point 2 - Magnetizing VoltageAt least 0
V3MRealpu0.79 [pu]Point 3 - Magnetizing VoltageAt least 0
V4MRealpu0.947 [pu]Point 4 - Magnetizing VoltageAt least 0
V5MRealpu1.076 [pu]Point 5 - Magnetizing VoltageAt least 0
V6MRealpu1.2 [pu]Point 6 - Magnetizing VoltageAt least 0
V7MRealpu1.26 [pu]Point 7 - Magnetizing VoltageAt least 0
V8MRealpu1.32 [pu]Point 8 - Magnetizing VoltageAt least 0
V9MRealpu1.42 [pu]Point 9 - Magnetizing VoltageAt least 0

Internal Parameters

ParameterUnitDefaultDescription
RdsRealpu7.14 [pu]Stator Resistance Auxiliary WindingEnter the resistance of the auxiliary windingAt least 0
RqsRealpu2.02 [pu]Stator Resistance Main WindingEnter the esistance of the main windingAt least 0
RrRealpu4.12 [pu]Rotor ResistanceEnter the resistance of the rotorAt least 0
XldsRealpu3.22 [pu]Stator Leakage Reactance Auxiliary WindingEnter the leakage reactance of the auxiliary windingAt least 0
XlqsRealpu2.79 [pu]Stator Leakage Reactance Main WindingEnter the leakage reactance of the main windingAt least 0
XlrRealpu2.95 [pu]Rotor Leakage ReactanceEnter the leakage reactance of the rotorAt least 0
XmsRealpu66.8 [pu]Unsaturated Magnetizing ReactanceEnter the unsaturated magnetizing reactanceAt least 0

Internal Output Variables

ParameterUnitDefaultDescription
SPDText··Mechanical Speed [pu]Range 0 to 0
Te1Text··Electrical Torque [pu]Range 0 to 0

Related

← master:pm_machine Permanent Magnet Machine · master:exc_scrx Solid State Exciter →