master:spim_uw parametersPSCAD Single Phase Induction Machine
Every parameter of the PSCAD Single Phase Induction Machine (master:spim_uw): 39 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().
What master:spim_uw is
Single Phase Induction Machine, a component of PSCAD's Master Library, filed under machines, exciters and governors.
- Definition
master:spim_uw- PSCAD name
- Single Phase Induction Machine
- Category
- Machines, exciters and governors
- Parameters
- 39, in 4 groups; 32 carry a unit
- Read from
- PSCAD 5.0.0, 2026-11-07
Read and write master:spim_uw in Python
import mhi.pscad
pscad = mhi.pscad.connect() # the PSCAD that is open; launch() starts one
project = pscad.project("my_case") # a case loaded in the workspace
for comp in project.find_all("master:spim_uw"): # the exact definition, namespace first
params = comp.parameters() # every parameter, as PSCAD holds it
print(str(params["D"])) # Mechanical Damping, in pu
comp = project.find_all("master:spim_uw")[0]
comp.parameters(D="1 [pu]") # a value that carries a unit is written with it
- A parameter is named exactly as in the table, letter case included:
parameters()gives every one of them in a dictionary, and a name the component does not have is refused. - A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (
str(...)) or the unit is lost. PSCAD keeps a written unit as it is given:"2500 [mohm]"stays in mohm. - A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
find_all()takes the exact definition only. A wildcard or a bare name withoutmaster:comes back empty; the Builder'spx_findwalks the pages for those.
The Builder's runtime does the same with the unit handled for you: px_get(comp, "D") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.
Configuration
| Parameter | Unit | Default | Description |
|---|---|---|---|
DReal | pu | 0.01 [pu] | Mechanical DampingEnter the mechanical damping coefficientAt least 0Used when MM==0 |
JReal | s | 0.7267 [s] | Angular Moment of Inertia (J=2H)Enter the moment of inertia of the machineAt least 0Used when MM==0 |
MMChoice | · | DISABLED | Multimass InterfaceSelect Enable or DisableWritten as DISABLED (Disabled), ENABLED (Enabled) |
MsatChoice | · | DISABLED | Mutual SaturationSelect Enable or DisableWritten as DISABLED (Disabled), ENABLED (Enabled) |
NReal | · | 1.0 | Stator Turns Ratio [auxiliary/main]Enter the turns ratio between auxcillary winding and the main windingAt least 0 |
NameText | · | · | Motor NameOptional: Enter a descriptive name if desiredRange 0 to 0 |
PBASEReal | MW | 0.01 [MW] | Rated PowerEnter the rated power of the machineAt least 0 |
VBASEReal | kV | 0.1 [kV] | Rated VoltageEnter the rated voltage of the machineAt least 0 |
freqReal | Hz | 60 [Hz] | Rated FrequencyEnter the rated frequency of the machineAt least 0 |
Mutual Saturation Curve (I,V)
| Parameter | Unit | Default | Description |
|---|---|---|---|
I10MReal | pu | 4.2 [pu] | Point 10 - Magnetizing CurrentAt least 0 |
I1MReal | pu | 0.0 | Point 1 - Magnetizing CurrentAt least 0Used when false |
I2MReal | pu | 0.5 [pu] | Point 2 - Magnetizing CurrentAt least 0 |
I3MReal | pu | 0.8 [pu] | Point 3 - Magnetizing CurrentAt least 0 |
I4MReal | pu | 1.0 [pu] | Point 4 - Magnetizing CurrentAt least 0 |
I5MReal | pu | 1.2 [pu] | Point 5 - Magnetizing CurrentAt least 0 |
I6MReal | pu | 1.5 [pu] | Point 6 - Magnetizing CurrentAt least 0 |
I7MReal | pu | 1.8 [pu] | Point 7 - Magnetizing CurrentAt least 0 |
I8MReal | pu | 2.2 [pu] | Point 8 - Magnetizing CurrentAt least 0 |
I9MReal | pu | 3.2 [pu] | Point 9 - Magnetizing CurrentAt least 0 |
NpntsChoice | · | 3 | Number of Points AvailableWritten as 3 = 3, 4 = 4, 5 = 5, 6 = 6, 7 = 7, 8 = 8, 9 = 9, 10 = 10 |
V10MReal | pu | 1.5 [pu] | Point 10 - Magnetizing VoltageAt least 0 |
V1MReal | pu | 0.0 | Point 1 - Magnetizing VoltageAt least 0Used when false |
V2MReal | pu | 0.5 [pu] | Point 2 - Magnetizing VoltageAt least 0 |
V3MReal | pu | 0.79 [pu] | Point 3 - Magnetizing VoltageAt least 0 |
V4MReal | pu | 0.947 [pu] | Point 4 - Magnetizing VoltageAt least 0 |
V5MReal | pu | 1.076 [pu] | Point 5 - Magnetizing VoltageAt least 0 |
V6MReal | pu | 1.2 [pu] | Point 6 - Magnetizing VoltageAt least 0 |
V7MReal | pu | 1.26 [pu] | Point 7 - Magnetizing VoltageAt least 0 |
V8MReal | pu | 1.32 [pu] | Point 8 - Magnetizing VoltageAt least 0 |
V9MReal | pu | 1.42 [pu] | Point 9 - Magnetizing VoltageAt least 0 |
Internal Parameters
| Parameter | Unit | Default | Description |
|---|---|---|---|
RdsReal | pu | 7.14 [pu] | Stator Resistance Auxiliary WindingEnter the resistance of the auxiliary windingAt least 0 |
RqsReal | pu | 2.02 [pu] | Stator Resistance Main WindingEnter the esistance of the main windingAt least 0 |
RrReal | pu | 4.12 [pu] | Rotor ResistanceEnter the resistance of the rotorAt least 0 |
XldsReal | pu | 3.22 [pu] | Stator Leakage Reactance Auxiliary WindingEnter the leakage reactance of the auxiliary windingAt least 0 |
XlqsReal | pu | 2.79 [pu] | Stator Leakage Reactance Main WindingEnter the leakage reactance of the main windingAt least 0 |
XlrReal | pu | 2.95 [pu] | Rotor Leakage ReactanceEnter the leakage reactance of the rotorAt least 0 |
XmsReal | pu | 66.8 [pu] | Unsaturated Magnetizing ReactanceEnter the unsaturated magnetizing reactanceAt least 0 |
Internal Output Variables
| Parameter | Unit | Default | Description |
|---|---|---|---|
SPDText | · | · | Mechanical Speed [pu]Range 0 to 0 |
Te1Text | · | · | Electrical Torque [pu]Range 0 to 0 |