master:th_tur parametersPSCAD Thermal Turbine

Every parameter of the PSCAD Thermal Turbine (master:th_tur): 19 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().

What master:th_tur is

Thermal Turbine, a component of PSCAD's Master Library, filed under machines, exciters and governors.

Definition
master:th_tur
PSCAD name
Thermal Turbine
Category
Machines, exciters and governors
Parameters
19, in 5 groups; 14 carry a unit
Read from
PSCAD 5.0.0, 2026-11-07

Read and write master:th_tur in Python

import mhi.pscad

pscad = mhi.pscad.connect()              # the PSCAD that is open; launch() starts one
project = pscad.project("my_case")       # a case loaded in the workspace

for comp in project.find_all("master:th_tur"):   # the exact definition, namespace first
    params = comp.parameters()           # every parameter, as PSCAD holds it
    print(str(params["K1"]))             # K1 Fraction, in pu

comp = project.find_all("master:th_tur")[0]
comp.parameters(K1="0.25 [pu]")          # a value that carries a unit is written with it
  • A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
  • A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
  • A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
  • find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.

The Builder's runtime does the same with the unit handled for you: px_get(comp, "K1") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.

Configuration

ParameterUnitDefaultDescription
CV_IText·CV_INPCV Initial Value: Variable(Same as Governor)
INITInteger·1Turbine Status: 0-Initialize,1-NormalRange -2147483648 to 2147483647
NameText··Name for IdentificationEnter a name for identification
PM0Realpu1.0Turbine (HP + LP)Initial Output PowerRange 0.0001 to 1
TH_TRChoice·YESControl of Intercept Valve?Written as NO (No), YES (Yes)

Intercept Valve

ParameterUnitDefaultDescription
IV_IText·IVINPIV Initial Value: Variable (Same as Governor)
PRMAXRealpu1.00Maximum Value of Reheat Pressure (PRmax)Range 0.1 to 2

Hp Turbine: Contributions

ParameterUnitDefaultDescription
K1Realpu0.125K1 FractionRange 0 to 1
K3Realpu0.125K3 FractionRange 0 to 1
K5Realpu0.125K5 FractionRange 0 to 1
K7Realpu0.125K7 FractionRange 0 to 1

Lp Turbine: Contributions

ParameterUnitDefaultDescription
K2Realpu0.125K2 FractionRange 0 to 1
K4Realpu0.125K4 FractionRange 0 to 1
K6Realpu0.125K6 FractionRange 0 to 1
K8Realpu0.125K8 FractionRange 0 to 1

Time Constants

ParameterUnitDefaultDescription
T4Reals1.0Steam Chest Time Constant (T4)At least 1E-10
T5Reals1.0Reheater Time Constant (T5)At least 1E-10
T6Reals1.0Reheater/Cross-over Time Constant (T6)At least 1E-10
T7Reals1.0Cross-over Time Constant (T7)At least 1E-10

Related