master:var_switch parametersPSCAD Two State Switch
Every parameter of the PSCAD Two State Switch (master:var_switch): 9 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().
What master:var_switch is
The two state switch: an input control that gives one of two values, which a script can set before a run.
- Definition
master:var_switch- PSCAD name
- Two State Switch
- Category
- Faults and switching
- Parameters
- 9, in 1 group
- Read from
- PSCAD 5.0.0, 2026-11-07
Most used master:var_switch parameters
| Parameter | Unit | Description |
|---|---|---|
Value | · | Initial Statethe state it starts in |
Max | · | Output Value in On Statethe value in the on state |
Min | · | Output Value in Off Statethe value in the off state |
Read and write master:var_switch in Python
import mhi.pscad
pscad = mhi.pscad.connect() # the PSCAD that is open; launch() starts one
project = pscad.project("my_case") # a case loaded in the workspace
for comp in project.find_all("master:var_switch"): # the exact definition, namespace first
params = comp.parameters() # every parameter, as PSCAD holds it
print(str(params["Value"])) # Initial State
comp = project.find_all("master:var_switch")[0]
comp.parameters(Value="ON") # a Choice is written as its symbol
- A parameter is named exactly as in the table, letter case included:
parameters()gives every one of them in a dictionary, and a name the component does not have is refused. - A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (
str(...)) or the unit is lost. PSCAD keeps a written unit as it is given:"2500 [mohm]"stays in mohm. - A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
find_all()takes the exact definition only. A wildcard or a bare name withoutmaster:comes back empty; the Builder'spx_findwalks the pages for those.
The Builder's runtime does the same with the unit handled for you: px_get(comp, "Value") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.
Configuration
| Parameter | Unit | Default | Description |
|---|---|---|---|
DisplayChoice | · | YES | Display Title on Icon?Written as NO (No), YES (Yes) |
GroupText | · | · | Group |
MaxReal | · | 1.0 | Output Value in On State |
MinReal | · | 0.0 | Output Value in Off State |
NameText | · | Var | TitleThis is used for display in control panel |
ToffText | · | OFF | Text for Off Position |
TonText | · | ON | Text for On Position |
ValueChoice | · | OFF | Initial StateWritten as OFF (Off), ON (On) |
convChoice | · | NO | Convert Output to the Nearest IntegerWritten as NO (No), YES (Yes) |