master:vg6p18 parametersPSCAD Generic Gamma Controller
Every parameter of the PSCAD Generic Gamma Controller (master:vg6p18): 9 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().
What master:vg6p18 is
Generic Gamma Controller, a component of PSCAD's Master Library, filed under other components.
- Definition
master:vg6p18- PSCAD name
- Generic Gamma Controller
- Category
- Other components
- Parameters
- 9, in 1 group; 8 carry a unit
- Read from
- PSCAD 5.0.0, 2026-11-07
Read and write master:vg6p18 in Python
import mhi.pscad
pscad = mhi.pscad.connect() # the PSCAD that is open; launch() starts one
project = pscad.project("my_case") # a case loaded in the workspace
for comp in project.find_all("master:vg6p18"): # the exact definition, namespace first
params = comp.parameters() # every parameter, as PSCAD holds it
print(str(params["AMAX"])) # Alpha Maximum Limit, in rad
comp = project.find_all("master:vg6p18")[0]
comp.parameters(AMAX="6.284 [rad]") # a value that carries a unit is written with it
- A parameter is named exactly as in the table, letter case included:
parameters()gives every one of them in a dictionary, and a name the component does not have is refused. - A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (
str(...)) or the unit is lost. PSCAD keeps a written unit as it is given:"2500 [mohm]"stays in mohm. - A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
find_all()takes the exact definition only. A wildcard or a bare name withoutmaster:comes back empty; the Builder'spx_findwalks the pages for those.
The Builder's runtime does the same with the unit handled for you: px_get(comp, "AMAX") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.
Configuration
| Parameter | Unit | Default | Description |
|---|---|---|---|
AMAXReal | rad | 3.142 | Alpha Maximum LimitRange 0 to 3.142 |
AMINReal | rad | 0.0 | Alpha Minimum LimitRange 0 to 3.142 |
CFReal | pu | 0.4 | Incremental Current LevelRange 0 to 1 |
FReal | Hz | 60.0 | Base FrequencyRange 1E-307 to 500 |
GIReal | 1/s | 15.0 | Integral GainRange 0 to 1000 |
GMINReal | rad | .3142 | Minimum Gamma OrderRange 0 to 3.142 |
GPReal | pu | 0.27 | Proportional GainRange 0 to 10 |
NameText | · | · | Name for IdentificationEnter a name for identification |
TFReal | s | 0.02 | Current Fade Out ConstantRange 0.001 to 1 |
Related
← master:polpi5 Generic Current Controller · master:import Import Symbol →