master:voltlvl parametersPSCAD voltlvl

Every parameter of the PSCAD voltlvl (master:voltlvl): 3 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().

What master:voltlvl is

voltlvl (Voltage Level Controller), a component of PSCAD's Master Library, filed under other components.

Definition
master:voltlvl
PSCAD name
voltlvl
Category
Other components
Parameters
3, in 1 group; 3 carry a unit
Read from
PSCAD 5.0.0, 2026-11-07

Read and write master:voltlvl in Python

import mhi.pscad

pscad = mhi.pscad.connect()              # the PSCAD that is open; launch() starts one
project = pscad.project("my_case")       # a case loaded in the workspace

for comp in project.find_all("master:voltlvl"):   # the exact definition, namespace first
    params = comp.parameters()           # every parameter, as PSCAD holds it
    print(str(params["beta"]))           # Firing angle for optimal harmonic control, in deg

comp = project.find_all("master:voltlvl")[0]
comp.parameters(beta="30 [deg]")         # a value that carries a unit is written with it
  • A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
  • A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
  • A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
  • find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.

The Builder's runtime does the same with the unit handled for you: px_get(comp, "beta") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.

Configuration

ParameterUnitDefaultDescription
betaRealdeg15.0Firing angle for optimal harmonic controlRange 0 to 90
del1Realdeg0.0Correction angle for Vcap control on + poleRange -20 to 20
del2Realdeg0.0Correction angle for Vcap control on - poleRange -20 to 20

Related

← master:unity Type Conversion · master:radiolink Wireless Radio Link →