master:xfmr_Nw parametersPSCAD Single Phase N Winding Transformer

Every parameter of the PSCAD Single Phase N Winding Transformer (master:xfmr_Nw): 116 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().

What master:xfmr_Nw is

Single Phase N Winding Transformer, a component of PSCAD's Master Library, filed under transformers and reactors.

Definition
master:xfmr_Nw
PSCAD name
Single Phase N Winding Transformer
Category
Transformers and reactors
Parameters
116, in 5 groups; 97 carry a unit
Read from
PSCAD 5.0.0, 2026-11-07

Read and write master:xfmr_Nw in Python

import mhi.pscad

pscad = mhi.pscad.connect()              # the PSCAD that is open; launch() starts one
project = pscad.project("my_case")       # a case loaded in the workspace

for comp in project.find_all("master:xfmr_Nw"):   # the exact definition, namespace first
    params = comp.parameters()           # every parameter, as PSCAD holds it
    print(str(params["CuL1"]))           # Copper Losses of Winding 1, in pu

comp = project.find_all("master:xfmr_Nw")[0]
comp.parameters(CuL1="1 [pu]")           # a value that carries a unit is written with it
  • A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
  • A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
  • A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
  • find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.

The Builder's runtime does the same with the unit handled for you: px_get(comp, "CuL1") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.

Winding Voltages and Losses

ParameterUnitDefaultDescription
CuL1Realpu0.0Copper Losses of Winding 1Enter the copper losses of winding 1 based on transformer ratingRange 0 to 1
CuL10Realpu0.0Copper Losses of Winding 10Enter the copper losses of winding 10 based on transformer ratingRange 0 to 1Used when N_wind>9
CuL11Realpu0.0Copper Losses of Winding 11Enter the copper losses of winding 11 based on transformer ratingRange 0 to 1Used when N_wind>10
CuL12Realpu0.0Copper Losses of Winding 12Enter the copper losses of winding 12 based on transformer ratingRange 0 to 1Used when N_wind>11
CuL2Realpu0.0Copper Losses of Winding 2Enter the copper losses of winding 2 based on transformer ratingRange 0 to 1
CuL3Realpu0.0Copper Losses of Winding 3Enter the copper losses of winding 3 based on transformer ratingRange 0 to 1
CuL4Realpu0.0Copper Losses of Winding 4Enter the copper losses of winding 4 based on transformer ratingRange 0 to 1
CuL5Realpu0.0Copper Losses of Winding 5Enter the copper losses of winding 5 based on transformer ratingRange 0 to 1
CuL6Realpu0.0Copper Losses of Winding 6Enter the copper losses of winding 6 based on transformer ratingRange 0 to 1Used when N_wind>5
CuL7Realpu0.0Copper Losses of Winding 7Enter the copper losses of winding 7 based on transformer ratingRange 0 to 1Used when N_wind>6
CuL8Realpu0.0Copper Losses of Winding 8Enter the copper losses of winding 8 based on transformer ratingRange 0 to 1Used when N_wind>7
CuL9Realpu0.0Copper Losses of Winding 9Enter the copper losses of winding 9 based on transformer ratingRange 0 to 1Used when N_wind>8
NLLRealpu0.0No Load LossesEnter the no load losses based on transformer ratingRange 0 to 1
V1RealkV230.0Winding 1 Line to Line Voltage (RMS)Enter the RMS voltage rating of winding 1At least 0.0001
V10RealkV230.0Winding 10 Line to Line Voltage (RMS)Enter the RMS voltage rating of winding 10At least 0.0001Used when N_wind>9
V11RealkV230.0Winding 11 Line to Line Voltage (RMS)Enter the RMS voltage rating of winding 11At least 0.0001Used when N_wind>10
V12RealkV230.0Winding 12 Line to Line Voltage (RMS)Enter the RMS voltage rating of winding 12At least 0.0001Used when N_wind>11
V2RealkV230.0Winding 2 Line to Line Voltage (RMS)Enter the RMS voltage rating of winding 2At least 0.0001
V3RealkV230.0Winding 3 Line to Line Voltage (RMS)Enter the RMS voltage rating of winding 3At least 0.0001
V4RealkV230.0Winding 4 Line to Line Voltage (RMS)Enter the RMS voltage rating of winding 4At least 0.0001
V5RealkV230.0Winding 5 Line to Line Voltage (RMS)Enter the RMS voltage rating of winding 5At least 0.0001
V6RealkV230.0Winding 6 Line to Line Voltage (RMS)Enter the RMS voltage rating of winding 6At least 0.0001Used when N_wind>5
V7RealkV230.0Winding 7 Line to Line Voltage (RMS)Enter the RMS voltage rating of winding 7At least 0.0001Used when N_wind>6
V8RealkV230.0Winding 8 Line to Line Voltage (RMS)Enter the RMS voltage rating of winding 8At least 0.0001Used when N_wind>7
V9RealkV230.0Winding 9 Line to Line Voltage (RMS)Enter the RMS voltage rating of winding 9At least 0.0001Used when N_wind>8

Saturation

ParameterUnitDefaultDescription
EnabChoice·NOSaturation EnabledSelect Yes or No to enable or disable the core saturation routineWritten as NO (No), YES (Yes)
Im1Real%0.4Magnetizing CurrentEnter the magnetizing current as a percentage of base currentRange 0.0001 to 50
SatChoice·_2Place Saturation on WindingSelect the winding # on which to place the magnetization branchWritten as _1 (#1), _2 (#2), _3 (#3), _4 (#4), _5 (#5), _6 (#6), _7 (#7), _8 (#8), _9 (#9), _10 (#10), _11 (#11), _12 (#12)
TxkReals0.0Time to Release Flux ClippingThis could be used to reduce start-up transientsRange 0 to 1000000
XairRealpu0.2Air Core ReactanceEnter the air core reactance based on transformer base impedanceRange 1E-08 to 1
XkneeRealpu1.17Knee VoltageEnter the knee point voltage corresponding to saturation curveAt least 1E-307

Internal Outputs

ParameterUnitDefaultDescription
FLUXText··Name for Flux Linkage [kWb-N]
IL1Text··Name for Winding 1 Current [kA]
IL10Text··Name for Winding 10 Current [kA]Used when N_wind>9
IL11Text··Name for Winding 11 Current [kA]Used when N_wind>10
IL12Text··Name for Winding 12 Current [kA]Used when N_wind>11
IL2Text··Name for Winding 2 Current [kA]
IL3Text··Name for Winding 3 Current [kA]
IL4Text··Name for Winding 4 Current [kA]
IL5Text··Name for Winding 5 Current [kA]
IL6Text··Name for Winding 6 Current [kA]Used when N_wind>5
IL7Text··Name for Winding 7 Current [kA]Used when N_wind>6
IL8Text··Name for Winding 8 Current [kA]Used when N_wind>7
IL9Text··Name for Winding 9 Current [kA]Used when N_wind>8
IMAGText··Name for Magnetizing Current [kA]

Configuration

ParameterUnitDefaultDescription
N_windChoice·5Number of WindingsSelect the number of windingsWritten as 5 = 5, 6 = 6, 7 = 7, 8 = 8, 9 = 9, 10 = 10, 11 = 11, 12 = 12
NameText··Name for identificationEnter a name for identification
TapChoice·NONETap Changer on WindingSelect the winding number on which to place the on-line tap changerWritten as NONE (None), _1 (#1), _2 (#2), _3 (#3), _4 (#4), _5 (#5), _6 (#6), _7 (#7), _8 (#8), _9 (#9), _10 (#10), _11 (#11), _12 (#12)
TmvaRealMVA100.0Transformer MVAEnter the apparent power rating of the transformerAt least 1E-06
fRealHz60.0Base Operation FrequencyEnter the base frequencyAt least 0.0001

Leakage Reactances

ParameterUnitDefaultDescription
Xl1011Realpu0.1Leakage Reactance (#10-#11)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>10
Xl1012Realpu0.1Leakage Reactance (#10-#12)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>11
Xl110Realpu0.1Leakage Reactance (#1-#10)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>9
Xl111Realpu0.1Leakage Reactance (#1-#11)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>10
Xl1112Realpu0.1Leakage Reactance (#11-#12)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>11
Xl112Realpu0.1Leakage Reactance (#1-#12)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>11
Xl12Realpu0.1Leakage Reactance (#1-#2)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1
Xl13Realpu0.1Leakage Reactance (#1-#3)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1
Xl14Realpu0.1Leakage Reactance (#1-#4)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1
Xl15Realpu0.1Leakage Reactance (#1-#5)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1
Xl16Realpu0.1Leakage Reactance (#1-#6)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>5
Xl17Realpu0.1Leakage Reactance (#1-#7)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>6
Xl18Realpu0.1Leakage Reactance (#1-#8)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>7
Xl19Realpu0.1Leakage Reactance (#1-#9)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>8
Xl210Realpu0.1Leakage Reactance (#2-#10)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>9
Xl211Realpu0.1Leakage Reactance (#2-#11)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>10
Xl212Realpu0.1Leakage Reactance (#2-#12)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>11
Xl23Realpu0.1Leakage Reactance (#2-#3)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1
Xl24Realpu0.1Leakage Reactance (#2-#4)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1
Xl25Realpu0.1Leakage Reactance (#2-#5)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1
Xl26Realpu0.1Leakage Reactance (#2-#6)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>5
Xl27Realpu0.1Leakage Reactance (#2-#7)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>6
Xl28Realpu0.1Leakage Reactance (#2-#8)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>7
Xl29Realpu0.1Leakage Reactance (#2-#9)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>8
Xl310Realpu0.1Leakage Reactance (#3-#10)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>9
Xl311Realpu0.1Leakage Reactance (#3-#11)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>10
Xl312Realpu0.1Leakage Reactance (#3-#12)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>11
Xl34Realpu0.1Leakage Reactance (#3-#4)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1
Xl35Realpu0.1Leakage Reactance (#3-#5)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1
Xl36Realpu0.1Leakage Reactance (#3-#6)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>5
Xl37Realpu0.1Leakage Reactance (#3-#7)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>6
Xl38Realpu0.1Leakage Reactance (#3-#8)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>7
Xl39Realpu0.1Leakage Reactance (#3-#9)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>8
Xl410Realpu0.1Leakage Reactance (#4-#10)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>9
Xl411Realpu0.1Leakage Reactance (#4-#11)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>10
Xl412Realpu0.1Leakage Reactance (#4-#12)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>11
Xl45Realpu0.1Leakage Reactance (#4-#5)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1
Xl46Realpu0.1Leakage Reactance (#4-#6)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>5
Xl47Realpu0.1Leakage Reactance (#4-#7)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>6
Xl48Realpu0.1Leakage Reactance (#4-#8)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>7
Xl49Realpu0.1Leakage Reactance (#4-#9)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>8
Xl510Realpu0.1Leakage Reactance (#5-#10)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>9
Xl511Realpu0.1Leakage Reactance (#5-#11)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>10
Xl512Realpu0.1Leakage Reactance (#5-#12)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>11
Xl56Realpu0.1Leakage Reactance (#5-#6)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>5
Xl57Realpu0.1Leakage Reactance (#5-#7)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>6
Xl58Realpu0.1Leakage Reactance (#5-#8)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>7
Xl59Realpu0.1Leakage Reactance (#5-#9)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>8
Xl610Realpu0.1Leakage Reactance (#6-#10)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>9
Xl611Realpu0.1Leakage Reactance (#6-#11)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>10
Xl612Realpu0.1Leakage Reactance (#6-#12)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>11
Xl67Realpu0.1Leakage Reactance (#6-#7)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>6
Xl68Realpu0.1Leakage Reactance (#6-#8)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>7
Xl69Realpu0.1Leakage Reactance (#6-#9)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>8
Xl710Realpu0.1Leakage Reactance (#7-#10)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>9
Xl711Realpu0.1Leakage Reactance (#7-#11)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>10
Xl712Realpu0.1Leakage Reactance (#7-#12)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>11
Xl78Realpu0.1Leakage Reactance (#7-#8)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>7
Xl79Realpu0.1Leakage Reactance (#7-#9)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>8
Xl810Realpu0.1Leakage Reactance (#8-#10)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>9
Xl811Realpu0.1Leakage Reactance (#8-#11)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>10
Xl812Realpu0.1Leakage Reactance (#8-#12)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>11
Xl89Realpu0.1Leakage Reactance (#8-#9)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>8
Xl910Realpu0.1Leakage Reactance (#9-#10)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>9
Xl911Realpu0.1Leakage Reactance (#9-#11)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>10
Xl912Realpu0.1Leakage Reactance (#9-#12)Enter the leakge reactance based on transformer base impedanceRange 1E-307 to 1Used when N_wind>11

Related

← master:xfmr_2w_auto Single Phase Auto Transformer · master:svc Static Var Compensator →