master:xy_table parametersPSCAD X-Y Table

Every parameter of the PSCAD X-Y Table (master:xy_table): 8 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().

What master:xy_table is

X-Y Table (X-Y table), a component of PSCAD's Master Library, filed under other components.

Definition
master:xy_table
PSCAD name
X-Y Table
Category
Other components
Parameters
8, in 1 group
Read from
PSCAD 5.0.0, 2026-11-07

Read and write master:xy_table in Python

import mhi.pscad

pscad = mhi.pscad.connect()              # the PSCAD that is open; launch() starts one
project = pscad.project("my_case")       # a case loaded in the workspace

for comp in project.find_all("master:xy_table"):   # the exact definition, namespace first
    params = comp.parameters()           # every parameter, as PSCAD holds it
    print(str(params["nrows"]))          # Number of Effective Rows

comp = project.find_all("master:xy_table")[0]
comp.parameters(nrows="20")              # written as text
  • A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
  • A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
  • A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
  • find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.

The Builder's runtime does the same with the unit handled for you: px_get(comp, "nrows") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.

Configuration

ParameterUnitDefaultDescription
FileText·datafileFile NameEnter the name of the fileRange 0 to 0Used when datasource==1
NChChoice·3Number of ColumnsSelect number of columnsWritten as 2, 3, 4, 5, 6, 7, 8, 9, 10, 11
NameText··Name for IdentificationEnter a name for identificationRange 0 to 0
datasourceChoice·TABLEData SourceSelect how the data is enteredWritten as TABLE (Table), EXTERNAL_FILE (External File)
datatableTable·[['Real (10', '11)']]Data TableUsed when datasource==0
intpChoice·INTERPOLATIONWhen Input is Between 2 Data Points, UseSelect what to do when data is in between specified pointsWritten as INTERPOLATION (interpolation), NEAREST_DATA_POINT (nearest data point)
nrowsInteger·10Number of Effective RowsRange 1 to 10Used when datasource==0
pathChoice·RELATIVEPathname to the Datafile is Given asSelect how the path to the file is enteredWritten as RELATIVE (relative pathname), ABSOLUTE (absolute pathname)Used when datasource==1

Related