ElmAsm attributesPowerFactory Asynchronous Machine

Every attribute of the PowerFactory Asynchronous Machine (ElmAsm): 303 input parameters and 1306 result variables, with units and meaning. Copy a name into GetAttribute or SetAttribute.

What ElmAsm is

An asynchronous (induction) machine, run as a motor or a generator.

Class
ElmAsm, element class
PowerFactory name
Asynchronous Machine
Type
TypAsm, through typ_id
Terminal suffix
:bus1 terminal
Attributes
303 input parameters and 1306 result variables, in 7 calculations

Most used ElmAsm attributes

AttributeUnitDescriptionWhere
m:P:bus1MWActive PowerLoad flow
m:Q:bus1MvarReactive PowerLoad flow
c:loading%LoadingLoad flow
s:slip%SlipslipLoad flow
pginiMWActive powerinput data
i_motยทGenerator/Motorgenerator or motorinput data
outservยทOut of Serviceinput data
s:speedp.u.Speedspeed (RMS simulation)RMS simulation

Read and write ElmAsm in Python

import powerfactory

app = powerfactory.GetApplication()          # GetApplicationExt() from outside PowerFactory
app.GetFromStudyCase("ComLdf").Execute()      # results exist after a calculation

for motor in app.GetCalcRelevantObjects("*.ElmAsm"):
    p_bus1 = motor.GetAttribute("m:P:bus1")       # Active Power, MW
    q_bus1 = motor.GetAttribute("m:Q:bus1")       # Reactive Power, Mvar
    print(motor.loc_name, p_bus1, q_bus1)

motor = app.GetCalcRelevantObjects("*.ElmAsm")[0]
motor.SetAttribute("pgini", 2)                # active power 2 MW
  • A result at a terminal of the asynchronous machine needs the terminal in its name: m:P:bus1, not m:P, which raises AttributeError.
  • An input parameter is read and written with or without its e: prefix: GetAttribute("outserv") and GetAttribute("e:outserv") give the same value.
  • RMS and EMT variables change over time: record them in a results object (ElmRes) to read the whole curve. GetAttribute after a run gives the value at the last time step.

ElmAsm input parameters

The element data, as typed in GetAttribute and SetAttribute (the e: prefix is optional). Setting one changes the model.

AttributeUnitDescription
loc_nameยทName
chr_nameยทCharacteristic Name
for_nameยทForeign Key
dat_srcยทData source
bustpยทBus type
sernumยทSerial Number
commissionDateยทCommissioning Date
appr_modbyยทModified by
mode_inpยทInput mode
outservยทOut of Service
ngnumยทparallel machines
pmodeยทInput mode
i_motยทGenerator/Motor
iconfedยทStatic converter-fed drive
i_remยทRemote control
i_psetยทEstimate active power
i_qsetยทEstimate reactive power
constrยทYear of Construction
appr_statusยทStatus
iAstabintยทA-stable integration algorithm
iintgndยทN-Connection
iUseStartยทUse motor starting method
iStartMethodยทMotor starting method
iTriggยทTriggered by...
idfigยทMachine type
outServPzeroยทOut of service when active power is zero
ictpgยทActive Power
ictqgยทReactive Power
iOPFCPminยทMin.
iOPFCPmaxยทMax.
iOPFCQminยทMin.
iOPFCQmaxยทMax.
QtargetBaseยทBase
iInterPolยทApproximation
polyDegreeยทPolynomial degree
isVREยทGenerator usage
isCtrlPยทActive power
isCtrlQยทReactive power
isLimPmaxยทMax.
isLimPminยทMin.
isLimQmaxยทMax.
isLimQminยทMin.
isMustRunUCยทMust run
isCtrlFixedToLdfValยทFix controls to Load Flow values
is4SpinReserveยทConsider for region spinning reserve
allowConsumModeยทSeparate consumption mode
isConsCostOpยทOperating costs
discMethCostOpยทPiecewise linearisation for LP
numBreakpointsCostOpยทNumber of breakpoints
isConsCostsRedispatchยทAdditional active power redispatch costs
isConsStartUpCostยทStart-up costs
isConsShutDownCostยทShut-down costs
isConstrRampยทRamp rate constraints
isConstrUpDownยทStart-up/shut-down time constraints
isDiscreteCtrlPยทRestriction to discrete active power values
isPcurrAllowedยทAllow current active power value
consCostsRedispatchQยทAdditional reactive power redispatch costs
refValueQยทReference value for redispatch costs
refValueLdfQยทReference value for redispatch costs
refValueVยทReference value for redispatch costs
ctrlUsagePยทActive Power
ctrlUsageQยทReactive Power
isConsCostOp_QยทReactive power operating costs
iInterPol_QยทApproximation
polyDegree_QยทPolynomial degree
discMethCostOp_QยทPiecewise linearisation for LP
priorityยทMerit Order
fixedยทMust run
iopt_slipยทSlip Settings
isCtrlPplacementยทOptimise active power
icurrefยทHarmonic currents referred to
iHmcTypeยทHarmonic Model
searchBlockTrfยทExternally modelled unit transformer
iShcModelยทShort-Circuit Model
shcDeadbandยทVoltage deadband
drawInrushยทDraw Inrush Current
drawStallยทDraw Thermal Overload
iNoShcContrยทNo Short-Circuit Contribution
mode_pgiยทModel
stowindยทWind Model
iopt_windmยทWind Model
pginiMWActive power
qginiMvarReactive power
pminiMWMechanical power
xmtinikNmMechanical torque
mdmexยทExponent
mdmlpp.u.Proportional factor
tstartsStarting Time
XeOhmReactance, Xe
ReOhmResistance, Re
TydsSwitch to 'D' after
speedydp.u.Switch to 'D' at speed >=
xrea%Reactance
ratedStrkVARated apparent power
TbypasssBypass after
speedbypp.u.Bypass at speed >=
autotap%Tap
TstaroffsRelease star contactor after
speedsoffp.u.Release star contactor at speed >=
usetpp.u.Voltage
usp_maxp.u.Max. voltage setpoint
usp_minp.u.Min. voltage setpoint
ddroop%Droop
KpfMW/HzPrim. frequency bias
q_minp.u.Min.
q_maxp.u.Max.
Pmin_ucMWMin.
Pmax_ucMWMax.
pmaxratfยทRating factor
smoothfac%Smoothing factor
smoothfac_Q%Smoothing Factor
slipset%Slip
IkskATransient Short-Circuit Current
KfactorยทK Factor
imaxp.u.Max. Current
uDeadbandp.u.Deadband
windspeedm/sWind speed
Jmekgm^2Moment of Inertia
gratioยทGear ratio
GPSlatdegLatitude / Northing
GPSlondegLongitude / Easting
dpl1ยทdpl1
dpl2ยทdpl2
dpl3ยทdpl3
dpl4ยทdpl4
dpl5ยทdpl5
scaleQmin%Scaling factor (min.)
scaleQmax%Scaling factor (max.)
QtargetRPR%Q target value
genShiftKey%Generation shift key
PminInvMWMin.
PmaxInvMWMax.
costCurtailmentUSD/MWhCosts for curtailment
penaltyCostsUSD/MWhPenalty costs
fixedCostsUSD/hFixed costs
consumCostsUSD/MWhConsumption costs
costRedispatchUpUSD/MWhUpward active power redispatch costs
costRedispatchDownUSD/MWhDownward active power redispatch costs
costRedispatchQUSD/MvarhCosts for reactive power deviation
cost_upUSDWarm-start costs
costColdStartUSDCold-start costs
coldStartTimehCold-start time
costShutDownUSDShut-down costs
limRampUpMW/hRamp-up limit
limRampDownMW/hRamp-down limit
limRampStartUpMWStart-up ramp limit
limRampShutDownMWShut-down ramp limit
minUpTimehMinimum up-time
minDownTimehMinimum down-time
targetQMvarQ target value
targetVp.u.Target voltage setpoint
fixedCostsSetpChangeQUSDFixed costs per setpoint deviation
zeroFixedCostsSetpChangeQUSDFixed costs per setpoint deviation
costRedispatchVUSD/p.u.Costs for voltage setpoint deviation
curativeLimPMWMax. curative active power deviation
curativeLimQMvarMax. curative reactive power deviation
curativeCostsUSD/MVAhCosts for curative power deviation
penaltyCosts_QUSD/MvarhPenalty costs
iWDmaxkAMax. instantaneous short-circuit current, iWDmax
kWDยทFactor kappaWD
rxWDยทRatio RWD/XWD
IkWDmaxkAMaximum current
IkWDminkAMinimum current
r2iecp.u.Resistance, r2
x2iecp.u.Reactance, x2
r0iecp.u.Resistance, r0
x0iecp.u.Reactance, x0
lambdam/sLambda
betaยทBeta
appr_modifยทModified
cpowerMWPower
ccostUSD/hCosts
vecBreakpointsPMWPower
vecStartUpTimes>=hDown-time
vecStartUpCostsUSDStart-up costs
vecDiscreteCtrlPvals%Valid active power values
cpower_QMvarPower
ccost_QUSD/hCosts
vecBreakpointsQMvarPower
chr_pMWActive Power
chr_slip%slip
cimRdfIdยทRDF ID
descยทDescription
fold_idยทIn Folder
typ_idยทTypeObject: TypAsm*,TypAsmo*,TypAsm1*
bus1ยทTerminalObject: StaCubic
bus1nยทNeutralObject: StaCubic
p_cubยทControlled branch (Cubicle)Object: StaCubic*
doc_idยทAdditional Data
pOwnerยทOwnerObject: ElmOwner
pOperatorยทOperatorObject: ElmOperator
pQlimTypeยทCapability curveObject: IntQlim
pQPcurveยทQ(P)-curveObject: IntQpcurve
efficiencyCurveGenยทEfficiency curve (generation)Object: IntEffcurve
efficiencyCurveConsumยทEfficiency curve (consumption)Object: IntEffcurve
pOpCostCurveยทGenerator cost curveObject: IntCostcurvegen
pBMUยทVirtual Power PlantObject: ElmBmu
phmcยทHarmonic CurrentsObject: TypHmccur,TypHmcopcur
pFlickerยทFlicker CoefficientsObject: TypFlicker
pGRStochStoGenStochastic Model
pPowerCrvยทWind Power CurveObject: TypPowercurve
pCharYrMWChaVec,ChaVecfile,ChaTime,ChaProfileTime Series Characteristics of Active Power Contribution (MW)
pCharYrWSChaVec,ChaVecfile,ChaTime,ChaProfileTime Series Characteristics for Wind Speed (m/s)
cpHeadFoldยทHead Folder
bus1_barยทTerminal
bus1n_barยทNeutral
cpGridยทGridObject: ElmNet
cpZoneยทZoneObject: ElmZone
cpAreaยทAreaObject: ElmArea
cpFeedยทFeederObject: ElmFeeder
ciDistยทDistance from infeed in number of buses
ciLaterยทLateral Index
ciDistRootยทDistance from first infeed in number of buses
ciDistAllยทDistance from infeed in number of buses including switches
ciDistAllRootยทDistance from first infeed in number of buses including switches
cpOwnerยทOwnerObject: ElmOwner
cpOperatorยทOperatorObject: ElmOperator
cpBranchยทBranchObject: ElmBranch
cpSiteยทSiteObject: ElmSite
cpSubstatยทSubstationObject: ElmSubstat,ElmTrfstat
cpMeteostatยทMeteo StationObject: ElmMeteostat
ciOutagedยทPlanned Outage
ciEnergizedยทEnergized
ciEarthedยทEarthed
cDisplayNameยทDisplay Name
cpSupplyTransformerยทSupplying TransformerObject: ElmTr?,ElmTrmult
cpSupplyTrfStationยทSupplying Secondary SubstationObject: ElmTrfstat
cpSupplySubstationยทSupplying SubstationObject: ElmSubstat
cgndยทStar Point
phtechยทTechnology
xmtnkNmRated mechanical torque
speed1php.u.Switch at speed >=
T1phsSwitch after
ctimesTime
cspeedp.u.Speed
crotorp.u.Additional rotor resistance
crraddp.u.Additional rotor resistance
c_pmodยทModelObject: ElmComp
c_pmdmยทMdmObject: ElmMdm*
av_modeยทLocal controller
c_pstacยทExternal station controllerObject: ElmStactrl
qdslCtrlยทQuasi-Dynamic ModelObject: ElmQdsl
sginiMVAApparent power
cosginiยทPower factor
pf_recapยทPower factor
p_direcยทPower direction
cQ_minMvarMinimum
cQ_maxMvarMaximum
Pmax_ucPUp.u.Max.
Pmin_ucPUp.u.Min.
PnomMWPr(rated)
P_maxMWMax.
avgCostsUSD/MWhAverage costs
costRedispatchPUSD/MWhCosts for active power deviation
cStorageยทStorage modelObject: ElmStorage
cIsMustRunUCยทMust run
efficiencyLPgenยทUsed efficiency (generation)
efficiencyLPconsumยทUsed efficiency (consumption)
allowGenModeยทSeparate generation mode
PminInvPUp.u.Min.
PmaxInvPUp.u.Max.
avgCostsUcUSD/MWhAverage costs
cfixedCostsUSD/hFixed costs
limRampUpPUp.u./hRamp-up limit
limRampDownPUp.u./hRamp-down limit
limRampStartUpPUp.u.Start-up ramp limit
limRampShutDownPUp.u.Shut-down ramp limit
cIsDiscreteCtrlPยทRestriction to discrete active power values
cVecDiscreteCtrlPvals%Valid active power values
cIsPcurrAllowedยทAllow current active power value
cCtrlUsagePยทActive Power
cCtrlUsageQยทReactive Power
cCurativeLimP_PUp.u.Max. curative active power deviation
cCurativeLimQ_PUp.u.Max. curative reactive power deviation
avgCostsUc_QUSD/MvarhAverage costs
avgCostsUc_posQUSD/MvarhAverage costs (pos. range)
avgCostsUc_negQUSD/MvarhAverage costs (neg. range)
isDispatchableยทGenerator Dispatch
cOperSpeedp.u.Operating speed
InomkANominal Current
cTypHmcยทType of harmonic sources
IratedkARated Current
pblocktrfยทUnit transformerObject: ElmTr2
IksskASubtransient Short-Circuit Current
crtoxยทR to X'' ratio
cJkgm^2Moment of Inertia from Type
cJtotkgm^2Total Moment of Inertia
ctagtotsTotal Acceleration Time Const.
pgini_aMWActive Power (act.)
qgini_aMvarReactive Power (act.)
sgini_aMVAApparent Power (act.)
cosgini_aยทPower Factor (act.)
pf_recap_aยทPower Factor Ind/Cap (act.)
windspeed_am/sWind speed (act.)
PngrelMWBased on rated active power (Pr)
meanm/sMean
variancem/sVariance
cnwsamplesยทNumber of Samples
FAYh/aFull Availability Expectancy
FOEh/aForced Outage Expectancy
EDSh/aExpectancy of derated states
cCategoryยทPlant Category
cSubCategoryยทSubcategory

ElmAsm load flow results

Read after ComLdf with GetAttribute. m: currents, voltages and powers, c: calculation parameter, n: bus result at a terminal, s: signal (state or model variable).

AttributeUnitDescription
m:urnet:bus1p.u.Voltage, Real Part, referred to network
m:uinet:bus1p.u.Voltage, Imaginary Part, referred to network
m:u1r:bus1p.u.Positive-Sequence-Voltage, Real Part
m:u1i:bus1p.u.Positive-Sequence-Voltage, Imaginary Part
m:u1:bus1p.u.Positive-Sequence-Voltage, Magnitude
m:U1:bus1kVLine-Ground Positive-Sequence-Voltage, Magnitude
m:U1l:bus1kVLine-Line Positive-Sequence-Voltage, Magnitude
m:phiu1:bus1degPositive-Sequence-Voltage, Angle
m:irnet:bus1p.u.Current, Real Part, referred to network
m:iinet:bus1p.u.Current, Imaginary Part, referred to network
m:inet:bus1p.u.Current, Magnitude, referred to network
m:I:bus1kACurrent, Magnitude
m:phii:bus1degCurrent, Angle
m:i1r:bus1p.u.Positive-Sequence Current, Real Part
m:i1i:bus1p.u.Positive-Sequence Current, Imaginary Part
m:i1:bus1p.u.Positive-Sequence Current, Magnitude
m:I1:bus1kAPositive-Sequence Current, Magnitude
m:phii1:bus1degPositive-Sequence Current, Angle
m:P:bus1MWActive Power
m:Q:bus1MvarReactive Power
m:S:bus1MVAApparent Power
m:cosphi:bus1ยทPower Factor
m:tanphi:bus1ยทtan(phi)
m:Psum:bus1MWTotal Active Power
m:Qsum:bus1MvarTotal Reactive Power
m:Ssum:bus1MVATotal Apparent Power
m:cosphisum:bus1ยทTotal Power Factor
m:tanphisum:bus1ยทTotal tan(phi)
m:i1P:bus1p.u.Positive-Sequence Active Current
m:i1Q:bus1p.u.Positive-Sequence Reactive Current
m:I1P:bus1kAPositive-Sequence Active Current
m:I1Q:bus1kAPositive-Sequence Reactive Current
m:ur:bus1p.u.Voltage, Real Part
m:ui:bus1p.u.Voltage, Imaginary Part
m:u:bus1p.u.Voltage, Magnitude
m:ir:bus1p.u.Current, Real Part
m:ii:bus1p.u.Current, Imaginary Part
m:i:bus1p.u.Current, Magnitude
m:phiui:bus1degAngle between Voltage and Current
m:phiu1i1:bus1degAngle between Voltage and Current in positive sequence system
m:Tfct:bus1sFault Clearing Time
m:Brkload:bus1%Breaker Loading
m:Spu:bus1MVA/p.u.Apparent Power per p.u. Voltage
m:urnet:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage, Real Part, referred to network
m:uinet:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage, Imaginary Part, referred to network
m:u0:bus1p.u.Zero-Sequence-Voltage, Magnitude
m:phiu0:bus1degZero-Sequence-Voltage, Angle
m:u2:bus1p.u.Negative-Sequence-Voltage, Magnitude
m:phiu2:bus1degNegative-Sequence-Voltage, Angle
m:irnet:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, Real Part, referred to network
m:iinet:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, Imaginary Part, referred to network
m:inet:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, Magnitude, referred to network
m:I:bus1:Aper phase :A, :B, :C, unbalanced onlykAPhase Current, Magnitude
m:phii:bus1:Aper phase :A, :B, :C, unbalanced onlydegPhase Current, Angle
m:i0r:bus1p.u.Zero-Sequence Current, Real Part
m:i0i:bus1p.u.Zero-Sequence Current, Imaginary Part
m:i0:bus1p.u.Zero-Sequence Current, Magnitude
m:I0:bus1kAZero-Sequence Current, Magnitude
m:I0x3:bus1kA3*I0
m:phii0:bus1degZero-Sequence Current, Angle
m:i2r:bus1p.u.Negative-Sequence Current, Real Part
m:i2i:bus1p.u.Negative-Sequence Current, Imaginary Part
m:i2:bus1p.u.Negative-Sequence Current, Magnitude
m:I2:bus1kANegative-Sequence Current, Magnitude
m:phii2:bus1degNegative-Sequence Current, Angle
m:ubfacI:bus1%Current Unbalance Factor
m:ubfacS:bus1%Power Unbalance Factor
m:P:bus1:Aper phase :A, :B, :C, unbalanced onlyMWActive Power
m:Q:bus1:Aper phase :A, :B, :C, unbalanced onlyMvarReactive Power
m:S:bus1:Aper phase :A, :B, :C, unbalanced onlyMVAApparent Power
m:cosphi:bus1:Aper phase :A, :B, :C, unbalanced onlyยทPower Factor
m:tanphi:bus1:Aper phase :A, :B, :C, unbalanced onlyยทtan(phi)
m:Pln:bus1:Aper phase :A, :B, :C, unbalanced onlyMWActive Power (Line-Neutral)
m:Qln:bus1:Aper phase :A, :B, :C, unbalanced onlyMvarReactive Power (Line-Neutral)
m:P1:bus1MWPositive Sequence Active Power
m:Q1:bus1MvarPositive Sequence Reactive Power
m:P2:bus1MWNegative Sequence Active Power
m:Q2:bus1MvarNegative Sequence Reactive Power
m:P0:bus1MWZero Sequence Active Power
m:Q0:bus1MvarZero Sequence Reactive Power
m:i2P:bus1p.u.Negative-Sequence Active Current
m:i2Q:bus1p.u.Negative-Sequence Reactive Current
m:I2P:bus1kANegative-Sequence Active Current
m:I2Q:bus1kANegative-Sequence Reactive Current
m:ur:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage, Real Part
m:ui:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage, Imaginary Part
m:u:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage, Magnitude
m:ir:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, Real Part
m:ii:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, Imaginary Part
m:i:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, Magnitude
m:phiui:bus1:Aper phase :A, :B, :C, unbalanced onlydegAngle between Voltage and Current
m:phiu0i0:bus1degAngle between Voltage and Current in zero-sequence system
m:phiu2i2:bus1degAngle between Voltage and Current in negative sequence system
m:TfctPh:bus1:Aper phase :A, :B, :C, unbalanced onlysFault Clearing Time
m:BrkloadPh:bus1:Aper phase :A, :B, :C, unbalanced only%Breaker Loading
c:cosnยทRated Power Factor
c:pMWActive Power (Electrical)
c:qMvarReactive Power
c:sgnnMVAsgnn
c:PnomMWPnom
c:pmMWMechanical Power
c:rstrp.u.Stator Resistance
c:xstrp.u.Stator Reactance
c:xrtrAp.u.Rotor Reactance A
c:xmp.u.Magnetising Reactance
c:frnomHzNominal Frequency
c:loading%Loading
c:i_conยทFlag for machine connection
c:pmsetMWMechanical Power Setpoint
c:xmtsetp.u.Mechanical Torque Setpoint
c:slipn%Nominal Slip
c:slipset%Slip Setpoint
c:i_motยทi_mot=0
c:zasmp.u.Equivalent Impedance
c:xmep.u.Electrical Torque
c:speedp.u.Speed
c:qcompMvarReactive Power for Compensation
c:zonewscaleยทWind generation zone scaling factor
c:PlossMWLosses (total)
c:QlossMvarReactive-Losses (total)
c:PlossldMWLosses (load)
c:QlossldMvarReactive-Losses (load)
c:PlossnldMWLosses (no load)
c:QlossnldMvarReactive-Losses (no load)
c:uinip.u.Voltage Setpoint for PV and Slack
c:rrtrp.u.Rotor Resistance
c:xmsatp.u.iini_iec
c:ksatp.u.iini_iec
c:xstr_totp.u.Total Stator reactance (including dependencies)
c:xrtr_totp.u.Total Rotor reactance (including dependencies)
c:irtrp.u.Rotor Current
c:i_slipยท0-Standard machine model, 2-With variable rotor resistance, 1-Linear level
c:slipk%Slip at Breakdown (Stalling) point
c:i_remยทRemote Control
c:psiMp.u.Magnetising Flux
c:slip0ยทslip setpoint
c:i_slimยทinternal
c:xrtrBp.u.Rotor Reactance B
c:xmrtrp.u.Rotor Leakage Reactance
c:mkยทStalling Torque
c:rrtrA0p.u.RrA0
c:xrtrA0p.u.XrA0
c:rr0p.u.Rr0
c:xr0p.u.Xr0
c:rr1p.u.Rr1
c:xr1p.u.Xr1
c:smMVAComplex Power
c:iPowerOnยทFlag
c:QminMvarLower limit of reactive power
c:QmaxMvarUpper limit of reactive power
c:QspareleadMvarQ spare lead
c:QsparelagMvarQ spare lag
c:i_qlimยทReactive power limit reached
c:i_vlimยทVoltage setpoint limit reached
c:PminMWLower limit of active power
c:PmaxMWUpper limit of active power
c:i_plimยทActive power limit reached
c:u1p.u.Internal
c:Kpp.u.Active Power Participation
c:Kqp.u.Reactive Power Participation
c:KpfMW/HzFrequency Bias
c:nCtrlIterยทNo. of CTRL-iterations
c:SnomMVANom. Apparent Power (1 mach.)
c:NnomยทNumber of Parallel Machines
c:rrtrAp.u.Rotor resistance
c:XmebaseNmBase torque
c:XmeNmElectrical torque
c:zasm2p.u.Negative Sequence Impedance
c:z0p.u.Zero Sequence Impedance
c:zep.u.Grounding Impedance
c:xme1p.u.Electrical Torque, Positive Sequence
c:xme2p.u.Electrical Torque, Negative Sequence
c:z2p.u.Negative Sequence Impedance
c:r2p.u.iini_iec
c:x2p.u.iini_iec
n:ur:bus1p.u.Voltage, Real Part
n:ui:bus1p.u.Voltage, Imaginary Part
n:u:bus1p.u.Voltage, Magnitude
n:upc:bus1%Voltage, Magnitude
n:du:bus1%Voltage Deviation
n:U:bus1kVLine-Ground Voltage, Magnitude
n:phiu:bus1degVoltage, Angle
n:phiurel:bus1degVoltage, Relative Angle
n:Ul:bus1kVLine-Line Voltage, Magnitude
n:u1:bus1p.u.Voltage, Magnitude
n:u1pc:bus1%Voltage, Magnitude
n:u1r:bus1p.u.Positive-Sequence Voltage, Real Part
n:u1i:bus1p.u.Positive-Sequence Voltage, Imaginary Part
n:Pgen:bus1MWGeneration, Active Power
n:Qgen:bus1MvarGeneration, Reactive Power
n:Pmot:bus1MWMotor Load, Active Power
n:Qmot:bus1MvarMotor Load, Reactive Power
n:Pload:bus1MWGeneral Load, Active Power
n:Qload:bus1MvarGeneral Load, Reactive Power
n:Pcomp:bus1MWCompensation (Losses)
n:Qcomp:bus1MvarCompensation
n:Pnet:bus1MWExternal Networks, Active Power
n:Qnet:bus1MvarExternal Networks, Reactive Power
n:Pflow:bus1MWPower Flow, Active Power
n:Qflow:bus1MvarPower Flow, Reactive Power
n:Pout:bus1MWOutgoing Flow, Active Power
n:Qout:bus1MvarOutgoing Power, Reactive Power
n:Sout:bus1MVAOutgoing Power, Apparent Power
n:cosphiout:bus1ยทOutgoing Power, Power Factor
n:Pbalance:bus1MWActive Power Balance (=0)
n:Qbalance:bus1MvarReactive Power Balance (=0)
n:LossPdown:bus1MWLosses, downstream
n:LossQdown:bus1MvarLosses, downstream (Reactive Power)
n:LossPdownload:bus1MWLoad losses, downstream
n:LossQdownload:bus1MvarLoad losses, downstream
n:LossPdownnoload:bus1MWNo load losses, downstream
n:LossQdownnoload:bus1MvarNo load losses, downstream
n:du_feed:bus1%Difference from voltage at start of feeder
n:ur:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Ground Voltage, Real Part
n:ui:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Ground Voltage, Imaginary Part
n:u:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Ground Voltage, Magnitude
n:upc:bus1:Aper phase :A, :B, :C, unbalanced only%Line-Ground Voltage, Magnitude
n:du:bus1:Aper phase :A, :B, :C, unbalanced only%Voltage Deviation
n:U:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Ground Voltage, Magnitude
n:phiu:bus1:Aper phase :A, :B, :C, unbalanced onlydegLine-Ground Voltage, Angle
n:ul:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Line Voltage, Magnitude
n:ulpc:bus1:Aper phase :A, :B, :C, unbalanced only%Line-Line Voltage, Magnitude
n:Ul:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Line Voltage, Magnitude
n:phiul:bus1:Aper phase :A, :B, :C, unbalanced onlydegLine-Line Voltage, Angle
n:u0:bus1p.u.Zero-Sequence Voltage, Magnitude
n:U0:bus1kVZero-Sequence Voltage, Magnitude
n:U0x3:bus1kV3*U0
n:phiu0:bus1degZero-Sequence Voltage, Angle
n:U1:bus1kVLine-Ground Positive-Sequence Voltage, Magnitude
n:phiu1:bus1degPositive-Sequence Voltage, Angle
n:u2:bus1p.u.Negative-Sequence Voltage, Magnitude
n:U2:bus1kVLine-Ground Negative-Sequence Voltage, Magnitude
n:phiu2:bus1degNegative-Sequence Voltage, Angle
n:U1l:bus1kVLine-Line Positive-Sequence Voltage, Magnitude
n:U2l:bus1kVLine-Line Negative-Sequence Voltage, Magnitude
n:uln:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Neutral Voltage, Magnitude
n:Uln:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Neutral Voltage, Magnitude
n:phiuln:bus1:Aper phase :A, :B, :C, unbalanced onlydegLine-Neutral Voltage, Angle
n:un:bus1p.u.Neutral-Ground Voltage, Magnitude
n:Un:bus1kVNeutral-Ground Voltage, Magnitude
n:phiun:bus1degNeutral-Ground Voltage, Angle
n:upht:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Technology dependent Voltage, Magnitude
n:Upht:bus1:Aper phase :A, :B, :C, unbalanced onlykVPhase Technology dependent Voltage, Magnitude
n:um:bus1p.u.Average-Voltage, Magnitude
n:Um:bus1kVAverage-Voltage, Magnitude
n:uphtmin:bus1p.u.Minimum of Phase Technology dependent Voltage, Magnitude
n:uphtmax:bus1p.u.Maximum of Phase Technology dependent Voltage, Magnitude
n:ubfac:bus1%Unbalance Factor
s:slip%Slip
s:psetMWActive Power Setpoint
s:rraddp.u.Additional Rotor Resistance
s:currtrrp.u.Rotor Current, Real Part
s:currtrip.u.Rotor Current, Imaginary Part
s:qsetMvarReactive Power Setpoint
s:dFinHzFrequency Deviation

ElmAsm short-circuit results

Read after ComShc with GetAttribute. m: currents, voltages and powers, c: calculation parameter, n: bus result at a terminal.

AttributeUnitDescription
m:I:bus1kAShort-Circuit Current, Magnitude
m:phii:bus1degPhase Current, Angle
m:i1:bus1p.u.Positive-Sequence Current, Magnitude
m:I1:bus1kAPositive-Sequence Current, Magnitude
m:phii1:bus1degPositive-Sequence Current, Angle
m:P:bus1MWActive Power
m:Q:bus1MvarReactive Power
m:i1P:bus1p.u.Positive-Sequence Active Current
m:i1Q:bus1p.u.Positive-Sequence Reactive Current
m:I1P:bus1kAPositive-Sequence Active Current
m:I1Q:bus1kAPositive-Sequence Reactive Current
m:phiui:bus1degAngle between Voltage and Current
m:phiu1i1:bus1degAngle between Voltage and Current in Positive-Sequence System
m:Tfct:bus1sFault Clearing Time
m:Ikss:bus1kAInitial Short-Circuit Current
m:ikss:bus1p.u.Initial Short-Circuit Current, Magnitude
m:Skss:bus1MVAInitial Short-Circuit Power
m:ip:bus1kAPeak Short-Circuit Current
m:maxIkss:bus1kAMax. Initial Short-Circuit Current
m:maxip:bus1kAMax. Peak Short-Circuit Current
m:maxIth:bus1kAMax. Thermal equivalent Short-Circuit Current
m:maxIb:bus1kAMax. Breaking Current
m:R:bus1OhmFault Impedance, Real Part
m:X:bus1OhmFault Impedance, Imaginary Part
m:Z:bus1OhmFault Impedance, Magnitude
m:phiz:bus1degFault Impedance, Angle
m:Rs:bus1OhmSource Impedance, Real Part
m:Xs:bus1OhmSource Impedance, Imaginary Part
m:Zs:bus1OhmSource Impedance, Magnitude
m:phizs:bus1degSource Impedance, Angle
m:BrkIpload:bus1%Breaker Loading (peak)
m:Ib:bus1kAShort-Circuit Breaking Current
m:Sb:bus1MVAShort-Circuit Breaking Power
m:Ith:bus1kAThermal equivalent Short-Circuit Current
m:zSbase:bus1p.u.Fault Impedance, Magnitude
m:XtoR:bus1ยทX/R ratio
m:cosphiui:bus1ยทcosphi
m:BrkIbload:bus1%Breaker Loading (breaking)
m:BrkmaxIb:bus1kAMax. Breaking Current (breaker time)
m:Ik:bus1kASteady-State Short-Circuit Current
m:I:bus1:Aper phase :A, :B, :C, unbalanced onlykAShort-Circuit Current, Magnitude
m:phii:bus1:Aper phase :A, :B, :C, unbalanced onlydegPhase Current, Angle
m:I0:bus1kAZero-Sequence Current, Magnitude
m:I0x3:bus1kA3*I0
m:phii0:bus1degZero-Sequence Current, Angle
m:I2:bus1kANegative-Sequence Current, Magnitude
m:phii2:bus1degNegative-Sequence Current, Angle
m:P:bus1:Aper phase :A, :B, :C, unbalanced onlyMWActive Power
m:Q:bus1:Aper phase :A, :B, :C, unbalanced onlyMvarReactive Power
m:Psum:bus1MWTotal Active Power
m:Qsum:bus1MvarTotal Reactive Power
m:cosphisum:bus1ยทTotal Power Factor
m:P2:bus1MWP2
m:Q2:bus1MvarQ2
m:P0:bus1MWP0
m:phiui:bus1:Aper phase :A, :B, :C, unbalanced onlydegAngle between Voltage and Current
m:phiu0i0:bus1degAngle between Voltage and Current in Zero-Sequence System
m:phiu2i2:bus1degAngle between Voltage and Current in Negative-Sequence System
m:TfctPh:bus1:Aper phase :A, :B, :C, unbalanced onlysFault Clearing Time
m:Ikss:bus1:Aper phase :A, :B, :C, unbalanced onlykAInitial Short-Circuit Current
m:ikss:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Initial Short-Circuit Current, Magnitude
m:Skss:bus1:Aper phase :A, :B, :C, unbalanced onlyMVAInitial Short-Circuit Power
m:Skssx3:bus1:Aper phase :A, :B, :C, unbalanced onlyMVA3*Initial Short-Circuit Power
m:ip:bus1:Aper phase :A, :B, :C, unbalanced onlykAPeak Short-Circuit Current
m:Z:bus1:Aper phase :A, :B, :C, unbalanced onlyOhmFault Impedance, Magnitude
m:phiz:bus1:Aper phase :A, :B, :C, unbalanced onlydegFault Impedance, Angle
m:Zl:bus1:Aper phase :A, :B, :C, unbalanced onlyOhmLine-Line Fault Impedance, Magnitude
m:phizl:bus1:Aper phase :A, :B, :C, unbalanced onlydegLine-Line Fault Impedance, Angle
m:Z0:bus1OhmZero-Sequence Fault Impedance, Magnitude
m:phiz0:bus1degZero-Sequence Fault Impedance, Angle
m:z0Sbase:bus1p.u.Zero-Sequence Fault Impedance, Magnitude
m:cosphiu1i1:bus1ยทPositive-Sequence cosphi
m:I0x3watt:bus1kAEarth-Fault Residual Current
m:I0x3var:bus1kACapacitive Earth-Fault Current
m:Q0cap:bus1MvarQ0 capacitive
m:Rfrel:bus1OhmRelay Impedance, Real Part
m:Xfrel:bus1OhmRelay Impedance, Imaginary Part
m:Zfrel:bus1OhmRelay Impedance, Magnitude
m:phizfrel:bus1degRelay Impedance, Angle
m:Zf:bus1OhmMeas. Fault Impedance, Magnitude
m:phizf:bus1degMeas. Fault Impedance, Angle
c:cosnยทPower Factor
c:nppolยทNo of Pole Pairs
c:uinip.u.Internal positive-sequence voltage
c:ngnumยทNo. of Machines in Parallel
c:ussp.u.Internal voltage
c:z1p.u.Positive-sequence impedance
c:isremoteยทRemote Contribution
c:IcontribkAContribution Current
c:currcontp.u.Contribution Current
c:iconfedยทStatic converter-fed drive
c:r1p.u.Positive-sequence resistance
c:x1p.u.Positive-sequence reactance
c:PrmMWRated Mechanical Power
c:imaxp.u.Max. Current
c:Zwdp.u.Impedance of doubly-fed asynchronous generator
c:sgnnMVATotal rated apparent power (ngnum*sgn)
c:zp.u.Impedance
c:z0p.u.Zero-sequence impedance
c:zep.u.Grounding impedance
c:z2p.u.Negative-sequence impedance
c:Icontrib:Aper phase :A, :B, :C, unbalanced onlykAContribution Current
c:y0p.u.Zero-sequence admittance
n:ur:bus1p.u.Voltage, Real Part
n:ui:bus1p.u.Voltage, Imaginary Part
n:u:bus1p.u.Voltage, Magnitude
n:upc:bus1%Voltage, Magnitude
n:du:bus1%Voltage Deviation
n:U:bus1kVLine-Ground Voltage, Magnitude
n:phiu:bus1degVoltage, Angle
n:Ul:bus1kVLine-Line Voltage, Magnitude
n:u1:bus1p.u.Voltage, Magnitude
n:u1pc:bus1%Voltage, Magnitude
n:u1r:bus1p.u.Positive-Sequence Voltage, Real Part
n:u1i:bus1p.u.Positive-Sequence Voltage, Imaginary Part
n:Ikss:bus1kAInitial Short-Circuit Current
n:I:bus1kAShort-Circuit Current
n:phii:bus1degPhase Current, Angle
n:Skss:bus1MVAInitial Short-Circuit Power
n:ip:bus1kAPeak Short-Circuit Current
n:Ib:bus1kAShort-Circuit Breaking Current
n:Sb:bus1MVAShort-Circuit Breaking Power
n:idc:bus1kADecaying Component
n:Ith:bus1kAThermal equivalent Short-Circuit Current
n:R1toX1:bus1ยทR1/X1 ratio (Zk")
n:X1toR1:bus1ยทX1/R1 ratio (Zk")
n:R:bus1OhmShort-Circuit Impedance, Real Part
n:X:bus1OhmShort-Circuit Impedance, Imaginary Part
n:Z:bus1OhmShort-Circuit Impedance, Magnitude
n:phiz:bus1degShort-Circuit Impedance, Angle
n:urpref:bus1p.u.Pre-fault Voltage, Real Part
n:uipref:bus1p.u.Pre-fault Voltage, Imaginary Part
n:upref:bus1p.u.Pre-fault Voltage, Magnitude
n:uprefpc:bus1%Pre-fault Voltage, Magnitude
n:Upref:bus1kVLine-Ground Pre-fault Voltage, Magnitude
n:Ulpref:bus1kVLine-Line Pre-fault Voltage, Magnitude
n:phiupref:bus1degPre-fault Voltage, Angle
n:phiui:bus1degAngle between Voltage and Current
n:Ithload:bus1%Loading, Thermal equivalent Current
n:Ipload:bus1%Loading, Peak Short-Circuit Current
n:Ithrtk:bus1kARated Short-Time Current (Tk)
n:XtoR:bus1ยทX/R ratio (peak)
n:RtoX:bus1ยทR/X ratio (peak)
n:XtoR_b:bus1ยทX/R ratio (dc)
n:RtoX_b:bus1ยทR/X ratio (dc)
n:fctof_b:bus1ยทEquivalent Frequency fc/f (dc)
n:rSbase:bus1p.u.Short-Circuit Impedance, Real Part
n:xSbase:bus1p.u.Short-Circuit Impedance, Imaginary Part
n:zSbase:bus1p.u.Short-Circuit Impedance, Magnitude
n:Tn:bus1msGrid Time Constant
n:Ik:bus1kASteady-State Short-Circuit Current
n:cfac:bus1ยทVoltage Factor
n:Iasy:bus1kAAsymmetrical Breaking Current
n:ur:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Ground Voltage, Real Part
n:ui:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Ground Voltage, Imaginary Part
n:u:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Ground Voltage, Magnitude
n:upc:bus1:Aper phase :A, :B, :C, unbalanced only%Line-Ground Voltage, Magnitude
n:du:bus1:Aper phase :A, :B, :C, unbalanced only%Voltage Deviation
n:U:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Ground Voltage, Magnitude
n:phiu:bus1:Aper phase :A, :B, :C, unbalanced onlydegLine-Ground Voltage, Angle
n:ul:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Line Voltage, Magnitude
n:ulpc:bus1:Aper phase :A, :B, :C, unbalanced only%Line-Line Voltage, Magnitude
n:Ul:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Line Voltage, Magnitude
n:phiul:bus1:Aper phase :A, :B, :C, unbalanced onlydegLine-Line Voltage, Angle
n:u0:bus1p.u.Zero-Sequence Voltage, Magnitude
n:U0:bus1kVZero-Sequence Voltage, Magnitude
n:U0x3:bus1kV3*U0
n:phiu0:bus1degZero-Sequence Voltage, Angle
n:U1:bus1kVLine-Ground Positive-Sequence Voltage, Magnitude
n:phiu1:bus1degPositive-Sequence Voltage, Angle
n:u2:bus1p.u.Negative-Sequence Voltage, Magnitude
n:U2:bus1kVLine-Ground Negative-Sequence Voltage, Magnitude
n:phiu2:bus1degNegative-Sequence Voltage, Angle
n:U1l:bus1kVLine-Line Positive-Sequence Voltage, Magnitude
n:U2l:bus1kVLine-Line Negative-Sequence Voltage, Magnitude
n:uln:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Neutral Voltage, Magnitude
n:Uln:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Neutral Voltage, Magnitude
n:phiuln:bus1:Aper phase :A, :B, :C, unbalanced onlydegLine-Neutral Voltage, Angle
n:un:bus1p.u.Neutral-Ground Voltage, Magnitude
n:Un:bus1kVNeutral-Ground Voltage, Magnitude
n:phiun:bus1degNeutral-Ground Voltage, Angle
n:upht:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Technology dependent Voltage, Magnitude
n:Upht:bus1:Aper phase :A, :B, :C, unbalanced onlykVPhase Technology dependent Voltage, Magnitude
n:Ikss:bus1:Aper phase :A, :B, :C, unbalanced onlykAInitial Short-Circuit Current
n:I:bus1:Aper phase :A, :B, :C, unbalanced onlykAShort-Circuit Current
n:phii:bus1:Aper phase :A, :B, :C, unbalanced onlydegPhase Current, Angle
n:Skss:bus1:Aper phase :A, :B, :C, unbalanced onlyMVAInitial Short-Circuit Power
n:Skssx3:bus1:Aper phase :A, :B, :C, unbalanced onlyMVA3*Initial Short-Circuit Power
n:ip:bus1:Aper phase :A, :B, :C, unbalanced onlykAPeak Short-Circuit Current
n:Ib:bus1:Aper phase :A, :B, :C, unbalanced onlykAShort-Circuit Breaking Current
n:Sb:bus1:Aper phase :A, :B, :C, unbalanced onlyMVAShort-Circuit Breaking Power
n:Ith:bus1:Aper phase :A, :B, :C, unbalanced onlykAThermal equivalent Short-Circuit Current
n:Ithmax:bus1kAMax. Thermal equivalent Short-Circuit Current
n:R0:bus1OhmZero-Sequence Impedance, Real Part
n:X0:bus1OhmZero-Sequence Impedance, Imaginary Part
n:Z0:bus1OhmZero-Sequence Impedance, Magnitude
n:phiz0:bus1degZero-Sequence Impedance, Angle
n:r0Sbase:bus1p.u.Zero-Sequence Impedance, Real Part
n:x0Sbase:bus1p.u.Zero-Sequence Impedance, Imaginary Part
n:z0Sbase:bus1p.u.Zero-Sequence Impedance, Magnitude
n:R1:bus1OhmPositive-Sequence Impedance, Real Part
n:X1:bus1OhmPositive-Sequence Impedance, Imaginary Part
n:Z1:bus1OhmPositive-Sequence Impedance, Magnitude
n:phiz1:bus1degPositive-Sequence Impedance, Angle
n:r1Sbase:bus1p.u.Positive-Sequence Impedance, Real Part
n:x1Sbase:bus1p.u.Positive-Sequence Impedance, Imaginary Part
n:z1Sbase:bus1p.u.Positive-Sequence Impedance, Magnitude
n:R2:bus1OhmNegative-Sequence Impedance, Real Part
n:X2:bus1OhmNegative-Sequence Impedance, Imaginary Part
n:Z2:bus1OhmNegative-Sequence Impedance, Magnitude
n:phiz2:bus1degNegative-Sequence Impedance, Angle
n:r2Sbase:bus1p.u.Negative-Sequence Impedance, Real Part
n:x2Sbase:bus1p.u.Negative-Sequence Impedance, Imaginary Part
n:z2Sbase:bus1p.u.Negative-Sequence Impedance, Magnitude
n:R0toX0:bus1ยทR0/X0 ratio (Zk")
n:X0toR0:bus1ยทX0/R0 ratio (Zk")
n:R2toX2:bus1ยทR2/X2 ratio (Zk")
n:X2toR2:bus1ยทX2/R2 ratio (Zk")
n:R:bus1:Aper phase :A, :B, :C, unbalanced onlyOhmNetwork Resistance, Line-Ground
n:X:bus1:Aper phase :A, :B, :C, unbalanced onlyOhmNetwork Reactance, Line-Ground
n:Z:bus1:Aper phase :A, :B, :C, unbalanced onlyOhmNetwork Impedance, Line-Ground
n:phiz:bus1:Aper phase :A, :B, :C, unbalanced onlydegAngle of Network Impedance, Line-Ground
n:Rl:bus1:Aper phase :A, :B, :C, unbalanced onlyOhmNetwork Resistance, Line-Line
n:Xl:bus1:Aper phase :A, :B, :C, unbalanced onlyOhmNetwork Reactance, Line-Line
n:Zl:bus1:Aper phase :A, :B, :C, unbalanced onlyOhmNetwork Impedance, Line-Line
n:phizl:bus1:Aper phase :A, :B, :C, unbalanced onlydegAngle of Network Impedance, Line-Line
n:Rln:bus1:Aper phase :A, :B, :C, unbalanced onlyOhmNetwork Resistance, Line-Neutral
n:Xln:bus1:Aper phase :A, :B, :C, unbalanced onlyOhmNetwork Reactance, Line-Neutral
n:Zln:bus1:Aper phase :A, :B, :C, unbalanced onlyOhmNetwork Impedance, Line-Neutral
n:phizln:bus1:Aper phase :A, :B, :C, unbalanced onlydegAngle of Network Impedance, Line-Neutral
n:Rn:bus1OhmNetwork Resistance, Neutral
n:Xn:bus1OhmNetwork Reactance, Neutral
n:Zn:bus1OhmNetwork Impedance, Neutral
n:phizn:bus1degAngle of Network Impedance, Neutral
n:eff:bus1:Aper phase :A, :B, :C, unbalanced onlyยทEarth Fault Factor
n:X0toX1:bus1ยทX0/X1
n:In:bus1kANeutral Current, Magnitude
n:phiin:bus1degNeutral Current, Angle
n:I0:bus1kAZero-Sequence Current, Magnitude
n:I0x3:bus1kA3*I0
n:phii0:bus1degZero-Sequence Current, Angle
n:I1:bus1kAPositive-Sequence Current, Magnitude
n:phii1:bus1degPositive-Sequence Current, Angle
n:I2:bus1kANegative-Sequence Current, Magnitude
n:phii2:bus1degNegative-Sequence Current, Angle
n:urpref:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Pre-fault Voltage, Real Part
n:uipref:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Pre-fault Voltage, Imaginary Part
n:upref:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Pre-fault Voltage, Magnitude
n:uprefpc:bus1:Aper phase :A, :B, :C, unbalanced only%Pre-fault Voltage, Magnitude
n:Upref:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Ground Pre-fault Voltage, Magnitude
n:Ulpref:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Line Pre-fault Voltage, Magnitude
n:phiupref:bus1:Aper phase :A, :B, :C, unbalanced onlydegPre-fault Voltage, Angle
n:phiui:bus1:Aper phase :A, :B, :C, unbalanced onlydegAngle between Voltage and Current
n:phiu1i1:bus1degAngle between Voltage and Current in positive sequence system
n:phiu2i2:bus1degAngle between Voltage and Current in negative sequence system
n:phiu0i0:bus1degAngle between Voltage and Current in zero-sequence system
n:Ik:bus1:Aper phase :A, :B, :C, unbalanced onlykASteady-State Short-Circuit Current
n:in:bus1p.u.Neutral Current, Magnitude
n:i0r:bus1p.u.Zero-Sequence Current, Real Part
n:i0i:bus1p.u.Zero-Sequence Current, Imaginary Part
n:i0:bus1p.u.Zero-Sequence Current, Magnitude
n:i1r:bus1p.u.Positive-Sequence Current, Real Part
n:i1i:bus1p.u.Positive-Sequence Current, Imaginary Part
n:i1:bus1p.u.Positive-Sequence Current, Magnitude
n:i2r:bus1p.u.Negative-Sequence Current, Real Part
n:i2i:bus1p.u.Negative-Sequence Current, Imaginary Part
n:i2:bus1p.u.Negative-Sequence Current, Magnitude

ElmAsm rms simulation results

Read after ComInc (RMS) with GetAttribute. m: currents, voltages and powers, c: calculation parameter, n: bus result at a terminal, s: signal (state or model variable).

AttributeUnitDescription
m:urnet:bus1p.u.Voltage, Real Part, referred to network
m:uinet:bus1p.u.Voltage, Imaginary Part, referred to network
m:u1r:bus1p.u.Positive-Sequence-Voltage, Real Part
m:u1i:bus1p.u.Positive-Sequence-Voltage, Imaginary Part
m:u1:bus1p.u.Positive-Sequence-Voltage, Magnitude
m:U1:bus1kVLine-Ground Positive-Sequence-Voltage, Magnitude
m:U1l:bus1kVLine-Line Positive-Sequence-Voltage, Magnitude
m:phiu1:bus1degPositive-Sequence-Voltage, Angle
m:irnet:bus1p.u.Current, Real Part, referred to network
m:iinet:bus1p.u.Current, Imaginary Part, referred to network
m:inet:bus1p.u.Current, Magnitude, referred to network
m:I:bus1kACurrent, Magnitude
m:phii:bus1degCurrent, Angle
m:i1r:bus1p.u.Positive-Sequence Current, Real Part
m:i1i:bus1p.u.Positive-Sequence Current, Imaginary Part
m:i1:bus1p.u.Positive-Sequence Current, Magnitude
m:I1:bus1kAPositive-Sequence Current, Magnitude
m:phii1:bus1degPositive-Sequence Current, Angle
m:P:bus1MWActive Power
m:Q:bus1MvarReactive Power
m:S:bus1MVAApparent Power
m:cosphi:bus1ยทPower Factor
m:tanphi:bus1ยทtan(phi)
m:Psum:bus1MWTotal Active Power
m:Qsum:bus1MvarTotal Reactive Power
m:Ssum:bus1MVATotal Apparent Power
m:cosphisum:bus1ยทTotal Power Factor
m:tanphisum:bus1ยทTotal tan(phi)
m:i1P:bus1p.u.Positive-Sequence Active Current
m:i1Q:bus1p.u.Positive-Sequence Reactive Current
m:I1P:bus1kAPositive-Sequence Active Current
m:I1Q:bus1kAPositive-Sequence Reactive Current
m:ur:bus1p.u.Voltage, Real Part
m:ui:bus1p.u.Voltage, Imaginary Part
m:u:bus1p.u.Voltage, Magnitude
m:ir:bus1p.u.Current, Real Part
m:ii:bus1p.u.Current, Imaginary Part
m:i:bus1p.u.Current, Magnitude
m:phiui:bus1degAngle between Voltage and Current
m:phiu1i1:bus1degAngle between Voltage and Current in positive sequence system
m:Tfct:bus1sFault Clearing Time
m:Brkload:bus1%Breaker Loading
m:Spu:bus1MVA/p.u.Apparent Power per p.u. Voltage
m:urnet:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage, Real Part, referred to network
m:uinet:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage, Imaginary Part, referred to network
m:u0:bus1p.u.Zero-Sequence-Voltage, Magnitude
m:phiu0:bus1degZero-Sequence-Voltage, Angle
m:u2:bus1p.u.Negative-Sequence-Voltage, Magnitude
m:phiu2:bus1degNegative-Sequence-Voltage, Angle
m:irnet:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, Real Part
m:iinet:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, Imaginary Part
m:inet:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, Magnitude
m:I:bus1:Aper phase :A, :B, :C, unbalanced onlykAPhase Current, Magnitude
m:phii:bus1:Aper phase :A, :B, :C, unbalanced onlydegPhase Current, Angle
m:i0r:bus1p.u.Zero-Sequence Current, Real Part
m:i0i:bus1p.u.Zero-Sequence Current, Imaginary Part
m:i0:bus1p.u.Zero-Sequence Current, Magnitude
m:I0:bus1kAZero-Sequence Current, Magnitude
m:I0x3:bus1kA3*I0
m:phii0:bus1degZero-Sequence Current, Angle
m:i2r:bus1p.u.Negative-Sequence Current, Real Part
m:i2i:bus1p.u.Negative-Sequence Current, Imaginary Part
m:i2:bus1p.u.Negative-Sequence Current, Magnitude
m:I2:bus1kANegative-Sequence Current, Magnitude
m:phii2:bus1degNegative-Sequence Current, Angle
m:P:bus1:Aper phase :A, :B, :C, unbalanced onlyMWActive Power
m:Q:bus1:Aper phase :A, :B, :C, unbalanced onlyMvarReactive Power
m:S:bus1:Aper phase :A, :B, :C, unbalanced onlyMVAApparent Power
m:cosphi:bus1:Aper phase :A, :B, :C, unbalanced onlyยทPower Factor
m:tanphi:bus1:Aper phase :A, :B, :C, unbalanced onlyยทtan(phi)
m:Pln:bus1:Aper phase :A, :B, :C, unbalanced onlyMWActive Power (Line-Neutral)
m:Qln:bus1:Aper phase :A, :B, :C, unbalanced onlyMvarReactive Power (Line-Neutral)
m:P1:bus1MWPositive Sequence Active Power
m:Q1:bus1MvarPositive Sequence Reactive Power
m:P2:bus1MWNegative Sequence Active Power
m:Q2:bus1MvarNegative Sequence Reactive Power
m:P0:bus1MWZero Sequence Active Power
m:Q0:bus1MvarZero Sequence Reactive Power
m:i2P:bus1p.u.Negative-Sequence Active Current
m:i2Q:bus1p.u.Negative-Sequence Reactive Current
m:I2P:bus1kANegative-Sequence Active Current
m:I2Q:bus1kANegative-Sequence Reactive Current
m:ur:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage, Real Part
m:ui:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage, Imaginary Part
m:u:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage, Magnitude
m:ir:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, Real Part
m:ii:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, Imaginary Part
m:i:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, Magnitude
m:phiui:bus1:Aper phase :A, :B, :C, unbalanced onlydegAngle between Voltage and Current
m:phiu0i0:bus1degAngle between Voltage and Current in zero-sequence system
m:phiu2i2:bus1degAngle between Voltage and Current in negative sequence system
m:TfctPh:bus1:Aper phase :A, :B, :C, unbalanced onlysFault Clearing Time
m:BrkloadPh:bus1:Aper phase :A, :B, :C, unbalanced only%Breaker Loading
c:cosnยทRated Power Factor
c:pMWp
c:rstrp.u.Stator Resistance
c:xstrp.u.Stator Reactance
c:rrtrAp.u.Rotor Resistance A
c:xrtrAp.u.Rotor Reactance A
c:xmp.u.Mag. Reactance
c:speednp.u.Nominal Asyn. Speed
c:frnomHzNominal Frequency
c:loading%Loading
c:i_motยทi_mot=0
c:xmep.u.Electrical Torque
c:hpirad/sNominal-Angular-Frequency
c:fep.u.Electrical Frequency
c:slip%Slip
c:xmtp.u.Mechanical Torque
c:xmemp.u.Electrical Torque (Motor)
c:addmtp.u.Additional Torque
c:mdmlpp.u.Proportional Factor
c:mdmexยทExponent
c:tagsAcceleration Time Constant
c:iTriggยทTriggered by
c:TydsY - D switching time
c:speedydsY - D switching speed
c:rrtrp.u.Rotor Resistance
c:xmsatp.u.Saturated Magnetising Reactance
c:ksatยทSaturation Factor
c:xstr_totp.u.Total Stator reactance (including dependencies)
c:islimp.u.Stator Current for Locked-Rotor and Nom. Voltage
c:irlimp.u.Rotor Current for Locked-Rotor and Nom. Voltage
c:xraddp.u.Additional Rotor Reactance
c:xstaddp.u.Additional Stator Reactance
c:xs_sump.u.Sum of Stator Circuit Reactances
c:xr_sump.u.Sum of Rotor Circuit Reactances
c:psiS_locp.u.Stator Flux, Local reference
c:psiR_locp.u.Rotor Flux, Local reference
c:us_locp.u.Stator Voltage, Local reference
c:im_locp.u.No-Load Current, Reactive, Local reference
c:ir_locp.u.Rotor Current, Local reference
c:ife_locp.u.No-Load Current, Resistive, Local reference
c:i_starยทStar/Delta
c:i_autoยทAuto Transformer
c:psiMp.u.Magnetising Flux
c:xreacp.u.Reactor Reactance
c:Tbypassp.u.Bypass time
c:speedbypp.u.Bypass speed
c:autotapp.u.Auto Transformer Tap
c:Tstaroffp.u.Star contactor off time
c:speedsoffp.u.Star contactor off speed
c:TagsAcceleration Time
c:currtrp.u.Rotor Current
c:curstrp.u.Stator Current
c:psim0ยทNominal magnetising flux
c:i_xmsatยทFlag
c:psistrrp.u.Stator Flux, d-axis
c:psistrip.u.Stator Flux, q-axis
c:rrtrBp.u.Rotor Resistance B
c:xrtrBp.u.Rotor Reactance B
c:xmrtrp.u.Rotor Leakage Reactance
c:xssp.u.Subtransient Reactance
c:is_rp.u.iini_iec
c:is_ip.u.iini_iec
c:UnrotkVRated Slip Ring Voltage
c:urdp.u.Rotor Voltage, d-Axis
c:urqp.u.Rotor Voltage, q-Axis
c:urap.u.Rotor Voltage, Phase a
c:urbp.u.Rotor Voltage, Phase b
c:urcp.u.Rotor Voltage, Phase c
c:IrdkARotor Current, d-Axis
c:IrqkARotor Current, q-Axis
c:IrakARotor Current, Phase a
c:IrbkARotor Current, Phase b
c:IrckARotor Current, Phase c
c:IrotkARotor Current, Magnitude of Phasor
c:z0p.u.Zero Sequence Impedance
c:zep.u.Grounding Impedance
c:xme1p.u.Electrical Torque, Positive Sequence
c:xme2p.u.Electrical Torque, Negative Sequence
c:z2p.u.Negative Sequence Impedance
n:ur:bus1p.u.Voltage, Real Part
n:ui:bus1p.u.Voltage, Imaginary Part
n:u:bus1p.u.Voltage, Magnitude
n:upc:bus1%Voltage, Magnitude
n:du:bus1%Voltage Deviation
n:U:bus1kVLine-Ground Voltage, Magnitude
n:phiu:bus1degVoltage, Angle
n:phiurel:bus1degVoltage, Relative Angle
n:Ul:bus1kVLine-Line Voltage, Magnitude
n:u1:bus1p.u.Voltage, Magnitude
n:u1pc:bus1%Voltage, Magnitude
n:u1r:bus1p.u.Positive-Sequence Voltage, Real Part
n:u1i:bus1p.u.Positive-Sequence Voltage, Imaginary Part
n:ishc:bus1p.u.Short-Circuit Current, magnitude
n:Ishc:bus1kAShort-Circuit Current, magnitude
n:fe:bus1p.u.Electrical Frequency
n:dfehz:bus1HzDeviation of the El. Frequency
n:fehz:bus1HzElectrical Frequency
n:frnom:bus1HzNominal Frequency
n:ishcr:bus1p.u.Short-Circuit Current, real
n:ishci:bus1p.u.Short-Circuit Current, imag
n:dfedt:bus1p.u./sDerivative of El. Frequency
n:ur:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Ground Voltage, Real Part
n:ui:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Ground Voltage, Imaginary Part
n:u:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Ground Voltage, Magnitude
n:upc:bus1:Aper phase :A, :B, :C, unbalanced only%Line-Ground Voltage, Magnitude
n:du:bus1:Aper phase :A, :B, :C, unbalanced only%Voltage Deviation
n:U:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Ground Voltage, Magnitude
n:phiu:bus1:Aper phase :A, :B, :C, unbalanced onlydegLine-Ground Voltage, Angle
n:ul:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Line Voltage, Magnitude
n:ulpc:bus1:Aper phase :A, :B, :C, unbalanced only%Line-Line Voltage, Magnitude
n:Ul:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Line Voltage, Magnitude
n:phiul:bus1:Aper phase :A, :B, :C, unbalanced onlydegLine-Line Voltage, Angle
n:u0:bus1p.u.Zero-Sequence Voltage, Magnitude
n:U0:bus1kVZero-Sequence Voltage, Magnitude
n:U0x3:bus1kV3*U0
n:phiu0:bus1degZero-Sequence Voltage, Angle
n:U1:bus1kVLine-Ground Positive-Sequence Voltage, Magnitude
n:phiu1:bus1degPositive-Sequence Voltage, Angle
n:u2:bus1p.u.Negative-Sequence Voltage, Magnitude
n:U2:bus1kVLine-Ground Negative-Sequence Voltage, Magnitude
n:phiu2:bus1degNegative-Sequence Voltage, Angle
n:U1l:bus1kVLine-Line Positive-Sequence Voltage, Magnitude
n:U2l:bus1kVLine-Line Negative-Sequence Voltage, Magnitude
n:uln:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Neutral Voltage, Magnitude
n:Uln:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Neutral Voltage, Magnitude
n:phiuln:bus1:Aper phase :A, :B, :C, unbalanced onlydegLine-Neutral Voltage, Angle
n:un:bus1p.u.Neutral-Ground Voltage, Magnitude
n:Un:bus1kVNeutral-Ground Voltage, Magnitude
n:phiun:bus1degNeutral-Ground Voltage, Angle
n:upht:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Technology dependent Voltage, Magnitude
n:Upht:bus1:Aper phase :A, :B, :C, unbalanced onlykVPhase Technology dependent Voltage, Magnitude
n:um:bus1p.u.Average-Voltage, Magnitude
n:Um:bus1kVAverage-Voltage, Magnitude
n:ishc:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Short-Circuit Current, magnitude
n:Ishc:bus1:Aper phase :A, :B, :C, unbalanced onlykAShort-Circuit Current, magnitude
n:inshc:bus1p.u.Neutral Short-Circuit Current, magnitude
n:Inshc:bus1kANeutral Short-Circuit Current, magnitude
n:ishcr:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Short-Circuit Current, real
n:ishci:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Short-Circuit Current, imag
s:speedp.u.Speed
s:phirefradReference angle
s:cosphiup.u.cos(Phiu)
s:sinphiup.u.sin(Phiu)
s:ptp.u.Turbine Power
s:xmdmp.u.MDM-Torque
s:frefp.u.Reference Frequency
s:xspeedp.u.Speed
s:pgtp.u.Active power
s:xmep.u.Electrical Torque
s:bcompp.u.Shunt for Compensation
s:speedInp.u.Speed input
s:rraddp.u.Additional Rotor Resistance
s:xrtr_totp.u.Total Rotor reactance (including dependencies)
s:psiR_rp.u.Rotor Flux, Real Part
s:psiR_ip.u.Rotor Flux, Imaginary Part
s:irotp.u.Rotor Current
s:currtrrp.u.Rotor Current, Real Part
s:currtrip.u.Rotor Current, Imaginary Part
s:psirtrrp.u.Rotor Flux, Real Part
s:psirtrip.u.Rotor Flux, Imaginary Part
s:psiA1_rp.u.Flux, Loop A1, Real Part
s:psiA1_ip.u.Flux, Loop A1, Imaginary Part
s:psiA2_rp.u.Flux, Loop A2, Real Part
s:psiA2_ip.u.Flux, Loop A2, Imaginary Part
s:psiB_rp.u.Flux, Loop B, Real Part
s:psiB_ip.u.Flux, Loop B, Imaginary Part
s:usrp.u.Rotor Voltage, Real Part
s:usip.u.Rotor Voltage, Imaginary Part
s:iqgridp.u.Reactive Current of Grid-Side Converter
s:irdp.u.Rotor Current, d-Axis
s:irqp.u.Rotor Current, q-Axis
s:xphimradRotor Angle
s:psis_rp.u.Stator Flux, Real Part
s:psis_ip.u.Stator Flux, Imaginary Part
s:cosphimยทcos(phim)
s:sinphimยทsin(phim)
s:psir_rp.u.Rotor Flux, Real Part
s:psir_ip.u.Rotor Flux, Imaginary Part
s:psiRf_rp.u.Rotor flux, forward component, real part
s:psiRf_ip.u.Rotor flux, forward component, imaginary part
s:psiRb_rp.u.Rotor flux, backward component, real part
s:psiRb_ip.u.Rotor flux, backward component, imaginary part
s:isf_rp.u.Stator current, forward component, real part
s:isf_ip.u.Stator current, forward component, imaginary part
s:isb_rp.u.Stator current, backward component, real part
s:isb_ip.u.Stator current, backward component, imaginary part

ElmAsm emt simulation results

Read after ComInc (EMT) with GetAttribute. m: currents, voltages and powers, c: calculation parameter, n: bus result at a terminal, s: signal (state or model variable).

AttributeUnitDescription
m:u0:bus1p.u.Zero-Sequence-Voltage
m:u1r:bus1p.u.Voltage Phasor, Real Part
m:u1i:bus1p.u.Voltage Phasor, Imaginary Part
m:u1:bus1p.u.Voltage Phasor, Magnitude
m:U1:bus1kVLine-Ground Voltage Phasor, Magnitude
m:U1l:bus1kVLine-Line Voltage Phasor, Magnitude
m:phiu1:bus1degVoltage Phasor, Angle
m:inet:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, referred to network
m:I:bus1:Aper phase :A, :B, :C, unbalanced onlykAPhase Current
m:i0:bus1p.u.Zero-Sequence Current
m:I0:bus1kAZero-Sequence Current
m:I0x3:bus1kA3*I0
m:i1r:bus1p.u.Current Phasor, Real Part
m:i1i:bus1p.u.Current Phasor, Imaginary Part
m:i1:bus1p.u.Current Phasor, Magnitude
m:I1:bus1kACurrent Phasor, Magnitude
m:phii1:bus1degCurrent Phasor, Angle
m:P:bus1:Aper phase :A, :B, :C, unbalanced onlyMWActive Power
m:Psum:bus1MWPower-Phasor, Active Power
m:Qsum:bus1MvarPower Phasor, Reactive Part
m:Ssum:bus1MVAPower Phasor, Apparent Power
m:i1P:bus1p.u.Current Phasor, Active Current
m:i1Q:bus1p.u.Current Phasor, Reactive Current
m:I1P:bus1kACurrent Phasor, Active Current
m:I1Q:bus1kACurrent Phasor, Reactive Current
m:u:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage
m:i:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current
m:phiu1i1:bus1degAngle between Voltage and Current Phasor
m:Tfct:bus1sFault Clearing Time
m:TfctPh:bus1:Aper phase :A, :B, :C, unbalanced onlysFault Clearing Time
m:unet:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage, referred to network
m:cosphi1:bus1ยทPower-Phasor, Power-Factor
c:cosnยทRated Power Factor
c:pMWp
c:rstrp.u.Stator Resistance
c:xstrp.u.Stator Reactance
c:rrtrAp.u.Rotor Resistance
c:xrtrAp.u.Rotor Reactance
c:xmp.u.Mag. Reactance
c:usp.u.Stator Voltage
c:isp.u.Stator Current
c:speednp.u.Nominal Asyn. Speed
c:frnomHzNominal Frequency
c:i_motยทi_mot=0
c:xmep.u.Electrical Torque
c:hpirad/sNominal-Angular-Frequency
c:slip%Slip
c:xmtp.u.Mechanical Torque
c:xmemp.u.Electrical Torque (Motor)
c:addmtp.u.Additional torque
c:mdmlpp.u.urc
c:mdmexยทIrd
c:tagsAcceleration Time Constant
c:iTriggยทTriggered by
c:TydsSwitching time
c:speedydp.u.Switching speed
c:ccompp.u.Capacitor for compensation
c:ir_dp.u.Rotor current, d-Axis
c:ir_qp.u.Rotor current, q-Axis
c:ir_ap.u.Rotor current, main winding
c:ir_bp.u.Rotor current, auxiliary winding
c:is_dp.u.Stator current, d-Axis
c:is_qp.u.Stator current, q-Axis
c:is_ap.u.Stator current, main winding
c:is_bp.u.Stator current, auxiliary winding
c:rrtrp.u.Rotor Resistance
c:xmsatp.u.Saturated Magnetising Reactance
c:ksatยทSaturation Factor
c:xstr_totp.u.Total Stator reactance (including dependencies)
c:islimp.u.Stator Current for Locked-Rotor and Nom. Voltage
c:irlimp.u.Rotor Current for Locked-Rotor and Nom. Voltage
c:xraddp.u.Additional Rotor Reactance
c:xstaddp.u.Additional Stator Reactance
c:xs_sump.u.Sum of Stator Circuit Reactances
c:xr_sump.u.Sum of Rotor Circuit Reactances
c:i_starยทStar/Delta
c:i_autoยทAuto Transformer
c:psiMp.u.Magnetising Flux
c:xreacp.u.Reactor Reactance
c:Tbypassp.u.Bypass time
c:speedbypp.u.Bypass speed
c:autotapp.u.Auto Transformer Tap
c:Tstaroffp.u.Star contactor off time
c:speedsoffp.u.Star contactor off speed
c:us_alphap.u.Stator Voltage, alpha-component
c:us_betap.u.Stator Voltage, beta-component
c:us_gammap.u.Stator Voltage, gamma-component
c:is_alphap.u.Stator Current, alpha-component
c:is_betap.u.Stator Current, beta-component
c:is_gammap.u.Stator Current, gamma-component
c:us_dqp.u.Stator Voltage, dq-system
c:is_dqp.u.Stator Current, dq-system
c:im_dqp.u.No-Load Current, Reactive, dq-system
c:ife_dqp.u.No-Load Current, Resistive, dq-system
c:psiS_dqp.u.Stator Flux, dq-system
c:TagsAcceleration Time
c:psim0p.u.Nominal magnetising flux
c:i_xmsatยทFlag
c:psirtr_eยทRotor Flux, emt
c:psistrp.u.Stator Flux, Referred to rotor
c:rrtrBp.u.Rotor Resistance B
c:xrtrBp.u.Rotor Reactance B
c:xmrtrp.u.Rotor Leakage Reactance
c:xssp.u.Subtransient Reactance
c:is_rp.u.iini_iec
c:is_ip.u.iini_iec
c:UnrotkVRated Slip Ring Voltage
c:urdp.u.Rotor Voltage, d-Axis
c:urqp.u.Rotor Voltage, q-Axis
c:urap.u.Rotor Voltage, Phase a
c:urbp.u.Rotor Voltage, Phase b
c:urcp.u.Rotor Voltage, Phase c
c:IrdkARotor Current, d-Axis
c:IrqkARotor Current, q-Axis
c:IrakARotor Current, Phase a
c:IrbkARotor Current, Phase b
c:IrckARotor Current, Phase c
c:IrotkARotor Current, Magnitude of Phasor
c:protยทPower, Rotor-Side Converter
c:igrd_aยทCurrent, grid-side converter, alpha-component
c:igrd_bยทCurrent, grid-side converter, beta-component
n:u:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage
n:upc:bus1:Aper phase :A, :B, :C, unbalanced only%Phase Voltage
n:U:bus1:Aper phase :A, :B, :C, unbalanced onlykVPhase Voltage
n:ul:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Line Voltage
n:ulpc:bus1:Aper phase :A, :B, :C, unbalanced only%Line-Line Voltage
n:Ul:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Line Voltage
n:u0:bus1p.u.Zero-Sequence-Voltage
n:U0:bus1kVZero-Sequence-Voltage
n:U0x3:bus1kV3*U0
n:u1:bus1p.u.Voltage Phasor, Magnitude
n:u1pc:bus1%Voltage Phasor, Magnitude
n:u1r:bus1p.u.Voltage Phasor, Real Part
n:u1i:bus1p.u.Voltage Phasor, Imaginary Part
n:U1:bus1kVVoltage Phasor, Magnitude
n:phiu1:bus1degVoltage Phasor, Angle
n:U1l:bus1kVLine-Line Voltage Phasor, Magnitude
n:uln:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Neutral Voltage
n:Uln:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Neutral Voltage
n:un:bus1p.u.Neutral-Ground Voltage
n:Un:bus1kVNeutral-Ground Voltage
n:ishc:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Short-Circuit Current
n:Ishc:bus1:Aper phase :A, :B, :C, unbalanced onlykAShort-Circuit Current
n:inshc:bus1p.u.Neutral Short-Circuit Current, magnitude
n:Inshc:bus1kANeutral Short-Circuit Current, magnitude
n:fe:bus1p.u.Electrical Frequency
n:dfehz:bus1HzDeviation of the El. Frequency
n:fehz:bus1HzElectrical Frequency
n:frnom:bus1HzNominal Frequency
s:speedradSpeed
s:phirefradReference angle
s:ptp.u.Turbine Power
s:xmdmp.u.MDM-Torque
s:xspeedp.u.Speed
s:pgtp.u.Active power
s:xmep.u.Electrical Torque
s:speedInp.u.Speed input
s:psiS_dp.u.Stator Flux, d-Axis
s:psiS_qp.u.Stator Flux, q-Axis
s:psiR_dp.u.Rotor Flux, d-Axis
s:psiR_qp.u.Rotor Flux, q-Axis
s:thetaRradRotor angular position (electrical)
s:rraddp.u.Additional Rotor Resistance
s:xrtr_totp.u.Total Rotor reactance (including dependencies)
s:irotp.u.Rotor Current
s:psiS_ap.u.Stator Flux, alpha-component
s:psiS_bp.u.Stator Flux, beta-component
s:ir_dp.u.Rotor Current, d-Axis
s:ir_qp.u.Rotor Current, q-Axis
s:phiradReference Angle
s:currtrrp.u.Rotor Current, Real Part
s:currtrip.u.Rotor Current, Imaginary Part
s:psirtrrp.u.Rotor Flux, Real Part
s:psirtrip.u.Rotor Flux, Imaginary Part
s:psistrrp.u.Stator Flux, Real Part
s:psistrip.u.Stator Flux, Imaginary Part
s:psiA1_rp.u.Flux, Loop A1, Real Part
s:psiA1_ip.u.Flux, Loop A1, Imaginary Part
s:psiA2_rp.u.Flux, Loop A2, Real Part
s:psiA2_ip.u.Flux, Loop A2, Imaginary Part
s:psiB_rp.u.Flux, Loop B, Real Part
s:psiB_ip.u.Flux, Loop B, Imaginary Part
s:phimradMechanical Angle (with reference to synchronous reference frame)
s:usrp.u.Rotor Voltage, Real Part
s:usip.u.Rotor Voltage, Imaginary Part
s:iqgridp.u.Reactive Current of Grid-Side Converter
s:irdp.u.Rotor Current, d-Axis
s:irqp.u.Rotor Current, q-Axis
s:xphimradRotor Angle
s:psis_rp.u.Stator Flux, Real Part
s:psis_ip.u.Stator Flux, Imaginary Part
s:cosphimยทcos(phim)
s:sinphimยทsin(phim)
s:psir_rp.u.Rotor-Flux, Real Part
s:psir_ip.u.Rotor-Flux, Imaginary Part
s:cosphiยทcos(phi)
s:sinphiยทsin(phi)

ElmAsm dc load flow results

Read after ComLdf (DC) with GetAttribute. m: currents, voltages and powers, c: calculation parameter, n: bus result at a terminal, s: signal (state or model variable).

AttributeUnitDescription
m:P:bus1MWActive Power
m:Q:bus1MvarReactive Power
c:cosnยทRated Power Factor
c:pMWActive Power (Electrical)
c:sgnnMVAPnom
c:PnomMWloading
c:loading%Loading
c:i_conยทFlag for machine connection
c:i_motยทi_mot=0
c:zonewscaleยทWind generation zone scaling factor
c:PlossMWLosses (total)
c:QlossMvarReactive-Losses (total)
c:i_remยทRemote Control
c:iPowerOnยทFlag
c:PminMWLower limit of active power
c:PmaxMWUpper limit of active power
c:i_plimยทActive power limit reached
c:Kpp.u.Active Power Participation
c:KpfMW/HzFrequency Bias
c:NnomยทNumber of Parallel Machines
c:cst_dispUSD/hOperating Costs
n:u:bus1p.u.Voltage, Magnitude
n:upc:bus1%Voltage, Magnitude
n:U:bus1kVLine-Ground Voltage, Magnitude
n:phiu:bus1degVoltage, Angle
n:phiurel:bus1degVoltage, Relative Angle
n:Ul:bus1kVLine-Line Voltage, Magnitude
n:u1:bus1p.u.Voltage, Magnitude
n:Pgen:bus1MWGeneration, Active Power
n:Pmot:bus1MWMotor Load, Active Power
n:Pload:bus1MWGeneral Load, Active Power
n:Pcomp:bus1MWCompensation (Losses)
n:Pnet:bus1MWExternal Networks, Active Power
n:Pflow:bus1MWPower Flow, Active Power
s:psetMWActive Power Setpoint
s:dFinHzFrequency Deviation

Read after ComMod with GetAttribute. c: calculation parameter, s: signal (state or model variable).

AttributeUnitDescription
c:cosnยทRated Power Factor
c:pMWp
c:rstrp.u.Stator Resistance
c:xstrp.u.Stator Reactance
c:rrtrAp.u.Rotor Resistance A
c:xrtrAp.u.Rotor Reactance A
c:xmp.u.Mag. Reactance
c:speednp.u.Nominal Asyn. Speed
c:frnomHzNominal Frequency
c:loading%Loading
c:i_motยทi_mot=0
c:xmep.u.Electrical Torque
c:hpirad/sNominal-Angular-Frequency
c:fep.u.Electrical Frequency
c:slip%Slip
c:xmtp.u.Mechanical Torque
c:xmemp.u.Electrical Torque (Motor)
c:addmtp.u.Additional Torque
c:mdmlpp.u.Proportional Factor
c:mdmexยทExponent
c:tagsAcceleration Time Constant
c:iTriggยทTriggered by
c:TydsY - D switching time
c:speedydsY - D switching speed
c:rrtrp.u.Rotor Resistance
c:xmsatp.u.Saturated Magnetising Reactance
c:ksatยทSaturation Factor
c:xstr_totp.u.Total Stator reactance (including dependencies)
c:islimp.u.Stator Current for Locked-Rotor and Nom. Voltage
c:irlimp.u.Rotor Current for Locked-Rotor and Nom. Voltage
c:xraddp.u.Additional Rotor Reactance
c:xstaddp.u.Additional Stator Reactance
c:xs_sump.u.Sum of Stator Circuit Reactances
c:xr_sump.u.Sum of Rotor Circuit Reactances
c:psiS_locp.u.Stator Flux, Local reference
c:psiR_locp.u.Rotor Flux, Local reference
c:us_locp.u.Stator Voltage, Local reference
c:im_locp.u.No-Load Current, Reactive, Local reference
c:ir_locp.u.Rotor Current, Local reference
c:ife_locp.u.No-Load Current, Resistive, Local reference
c:i_starยทStar/Delta
c:i_autoยทAuto Transformer
c:psiMp.u.Magnetising Flux
c:xreacp.u.Reactor Reactance
c:Tbypassp.u.Bypass time
c:speedbypp.u.Bypass speed
c:autotapp.u.Auto Transformer Tap
c:Tstaroffp.u.Star contactor off time
c:speedsoffp.u.Star contactor off speed
c:TagsAcceleration Time
c:currtrp.u.Rotor Current
c:curstrp.u.Stator Current
c:psim0ยทNominal magnetising flux
c:i_xmsatยทFlag
c:psistrrp.u.Stator Flux, d-axis
c:psistrip.u.Stator Flux, q-axis
c:rrtrBp.u.Rotor Resistance B
c:xrtrBp.u.Rotor Reactance B
c:xmrtrp.u.Rotor Leakage Reactance
c:xssp.u.Subtransient Reactance
c:is_rp.u.iini_iec
c:is_ip.u.iini_iec
c:UnrotkVRated Slip Ring Voltage
c:urdp.u.Rotor Voltage, d-Axis
c:urqp.u.Rotor Voltage, q-Axis
c:urap.u.Rotor Voltage, Phase a
c:urbp.u.Rotor Voltage, Phase b
c:urcp.u.Rotor Voltage, Phase c
c:IrdkARotor Current, d-Axis
c:IrqkARotor Current, q-Axis
c:IrakARotor Current, Phase a
c:IrbkARotor Current, Phase b
c:IrckARotor Current, Phase c
c:IrotkARotor Current, Magnitude of Phasor
s:speedp.u.Speed
s:phirefradReference angle
s:cosphiup.u.cos(Phiu)
s:sinphiup.u.sin(Phiu)
s:ptp.u.Turbine Power
s:xmdmp.u.MDM-Torque
s:frefp.u.Reference Frequency
s:xspeedp.u.Speed
s:pgtp.u.Active power
s:xmep.u.Electrical Torque
s:bcompp.u.Shunt for Compensation
s:speedInp.u.Speed input
s:rraddp.u.Additional Rotor Resistance
s:xrtr_totp.u.Total Rotor reactance (including dependencies)
s:psiR_rp.u.Rotor Flux, Real Part
s:psiR_ip.u.Rotor Flux, Imaginary Part
s:irotp.u.Rotor Current
s:currtrrp.u.Rotor Current, Real Part
s:currtrip.u.Rotor Current, Imaginary Part
s:psirtrrp.u.Rotor Flux, Real Part
s:psirtrip.u.Rotor Flux, Imaginary Part
s:psiA1_rp.u.Flux, Loop A1, Real Part
s:psiA1_ip.u.Flux, Loop A1, Imaginary Part
s:psiA2_rp.u.Flux, Loop A2, Real Part
s:psiA2_ip.u.Flux, Loop A2, Imaginary Part
s:psiB_rp.u.Flux, Loop B, Real Part
s:psiB_ip.u.Flux, Loop B, Imaginary Part
s:usrp.u.Rotor Voltage, Real Part
s:usip.u.Rotor Voltage, Imaginary Part
s:iqgridp.u.Reactive Current of Grid-Side Converter
s:irdp.u.Rotor Current, d-Axis
s:irqp.u.Rotor Current, q-Axis
s:xphimradRotor Angle
s:psis_rp.u.Stator Flux, Real Part
s:psis_ip.u.Stator Flux, Imaginary Part
s:cosphimยทcos(phim)
s:sinphimยทsin(phim)
s:psir_rp.u.Rotor Flux, Real Part
s:psir_ip.u.Rotor Flux, Imaginary Part

ElmAsm optimal power flow results

Read after ComOpf with GetAttribute. m: currents, voltages and powers, c: calculation parameter, n: bus result at a terminal.

AttributeUnitDescription
m:urnet:bus1p.u.Voltage, Real Part, referred to network
m:uinet:bus1p.u.Voltage, Imaginary Part, referred to network
m:u1r:bus1p.u.Positive-Sequence-Voltage, Real Part
m:u1i:bus1p.u.Positive-Sequence-Voltage, Imaginary Part
m:u1:bus1p.u.Positive-Sequence-Voltage, Magnitude
m:U1:bus1kVLine-Ground Positive-Sequence-Voltage, Magnitude
m:U1l:bus1kVLine-Line Positive-Sequence-Voltage, Magnitude
m:phiu1:bus1degPositive-Sequence-Voltage, Angle
m:irnet:bus1p.u.Current, Real Part, referred to network
m:iinet:bus1p.u.Current, Imaginary Part, referred to network
m:inet:bus1p.u.Current, Magnitude, referred to network
m:I:bus1kACurrent, Magnitude
m:phii:bus1degCurrent, Angle
m:i1r:bus1p.u.Positive-Sequence Current, Real Part
m:i1i:bus1p.u.Positive-Sequence Current, Imaginary Part
m:i1:bus1p.u.Positive-Sequence Current, Magnitude
m:I1:bus1kAPositive-Sequence Current, Magnitude
m:phii1:bus1degPositive-Sequence Current, Angle
m:P:bus1MWActive Power
m:Q:bus1MvarReactive Power
m:S:bus1MVAApparent Power
m:cosphi:bus1ยทPower Factor
m:tanphi:bus1ยทtan(phi)
m:Psum:bus1MWTotal Active Power
m:Qsum:bus1MvarTotal Reactive Power
m:Ssum:bus1MVATotal Apparent Power
m:cosphisum:bus1ยทTotal Power Factor
m:tanphisum:bus1ยทTotal tan(phi)
m:i1P:bus1p.u.Positive-Sequence Active Current
m:i1Q:bus1p.u.Positive-Sequence Reactive Current
m:I1P:bus1kAPositive-Sequence Active Current
m:I1Q:bus1kAPositive-Sequence Reactive Current
m:ur:bus1p.u.Voltage, Real Part
m:ui:bus1p.u.Voltage, Imaginary Part
m:u:bus1p.u.Voltage, Magnitude
m:ir:bus1p.u.Current, Real Part
m:ii:bus1p.u.Current, Imaginary Part
m:i:bus1p.u.Current, Magnitude
m:phiui:bus1degAngle between Voltage and Current
m:phiu1i1:bus1degAngle between Voltage and Current in positive sequence system
m:Tfct:bus1sFault Clearing Time
m:Brkload:bus1%Breaker Loading
m:Spu:bus1MVA/p.u.Apparent Power per p.u. Voltage
c:cosnยทRated Power Factor
c:pMWActive Power (Electrical)
c:qMvarReactive Power
c:sgnnMVAsgnn
c:PnomMWPnom
c:pmMWMechanical Power
c:rstrp.u.Stator Resistance
c:xstrp.u.Stator Reactance
c:xrtrAp.u.Rotor Reactance A
c:xmp.u.Magnetising Reactance
c:frnomHzNominal Frequency
c:loading%Loading
c:i_conยทFlag for machine connection
c:pmsetMWMechanical Power Setpoint
c:xmtsetp.u.Mechanical Torque Setpoint
c:slipn%Nominal Slip
c:slipset%Slip Setpoint
c:i_motยทi_mot=0
c:zasmp.u.Equivalent Impedance
c:xmep.u.Electrical Torque
c:speedp.u.Speed
c:qcompMvarReactive Power for Compensation
c:zonewscaleยทWind generation zone scaling factor
c:PlossMWLosses (total)
c:QlossMvarReactive-Losses (total)
c:PlossldMWLosses (load)
c:QlossldMvarReactive-Losses (load)
c:PlossnldMWLosses (no load)
c:QlossnldMvarReactive-Losses (no load)
c:uinip.u.Voltage Setpoint for PV and Slack
c:rrtrp.u.Rotor Resistance
c:xmsatp.u.iini_iec
c:ksatp.u.iini_iec
c:xstr_totp.u.Total Stator reactance (including dependencies)
c:xrtr_totp.u.Total Rotor reactance (including dependencies)
c:irtrp.u.Rotor Current
c:i_slipยท0-Standard machine model, 2-With variable rotor resistance, 1-Linear level
c:slipk%Slip at Breakdown (Stalling) point
c:i_remยทRemote Control
c:psiMp.u.Magnetising Flux
c:slip0ยทslip setpoint
c:i_slimยทinternal
c:xrtrBp.u.Rotor Reactance B
c:xmrtrp.u.Rotor Leakage Reactance
c:mkยทStalling Torque
c:rrtrA0p.u.RrA0
c:xrtrA0p.u.XrA0
c:rr0p.u.Rr0
c:xr0p.u.Xr0
c:rr1p.u.Rr1
c:xr1p.u.Xr1
c:smMVAComplex Power
c:iPowerOnยทFlag
c:QminMvarLower limit of reactive power
c:QmaxMvarUpper limit of reactive power
c:QspareleadMvarQ spare lead
c:QsparelagMvarQ spare lag
c:i_qlimยทReactive power limit reached
c:i_vlimยทVoltage setpoint limit reached
c:PminMWLower limit of active power
c:PmaxMWUpper limit of active power
c:Pmax_ucMWUpper limit of active power
c:Pmin_ucMWLower limit of active power
c:i_plimยทActive power limit reached
c:u1p.u.Internal
c:Kpp.u.Active Power Participation
c:Kqp.u.Reactive Power Participation
c:KpfMW/HzFrequency Bias
c:nCtrlIterยทNo. of CTRL-iterations
c:SnomMVANom. Apparent Power (1 mach.)
c:NnomยทNumber of Parallel Machines
c:QtargetMvarQ target value
c:QtargetDeltaMvarDeviation from Q target value
c:cst_dispUSD/hOperating Costs
c:PtargetMWP target value
c:totRedispatchPMWhTotal redispatched energy
c:totRedispatchQMvarhTotal redispatched energy
c:totRedispatchCostsUSDTotal redispatch costs
n:ur:bus1p.u.Voltage, Real Part
n:ui:bus1p.u.Voltage, Imaginary Part
n:u:bus1p.u.Voltage, Magnitude
n:upc:bus1%Voltage, Magnitude
n:du:bus1%Voltage Deviation
n:U:bus1kVLine-Ground Voltage, Magnitude
n:phiu:bus1degVoltage, Angle
n:phiurel:bus1degVoltage, Relative Angle
n:Ul:bus1kVLine-Line Voltage, Magnitude
n:u1:bus1p.u.Voltage, Magnitude
n:u1pc:bus1%Voltage, Magnitude
n:u1r:bus1p.u.Positive-Sequence Voltage, Real Part
n:u1i:bus1p.u.Positive-Sequence Voltage, Imaginary Part
n:Pgen:bus1MWGeneration, Active Power
n:Qgen:bus1MvarGeneration, Reactive Power
n:Pmot:bus1MWMotor Load, Active Power
n:Qmot:bus1MvarMotor Load, Reactive Power
n:Pload:bus1MWGeneral Load, Active Power
n:Qload:bus1MvarGeneral Load, Reactive Power
n:Pcomp:bus1MWCompensation (Losses)
n:Qcomp:bus1MvarCompensation
n:Pnet:bus1MWExternal Networks, Active Power
n:Qnet:bus1MvarExternal Networks, Reactive Power
n:Pflow:bus1MWPower Flow, Active Power
n:Qflow:bus1MvarPower Flow, Reactive Power
n:Pout:bus1MWOutgoing Flow, Active Power
n:Qout:bus1MvarOutgoing Power, Reactive Power
n:Sout:bus1MVAOutgoing Power, Apparent Power
n:cosphiout:bus1ยทOutgoing Power, Power Factor
n:Pbalance:bus1MWActive Power Balance (=0)
n:Qbalance:bus1MvarReactive Power Balance (=0)
n:LossPdown:bus1MWLosses, downstream
n:LossQdown:bus1MvarLosses, downstream (Reactive Power)
n:LossPdownload:bus1MWLoad losses, downstream
n:LossQdownload:bus1MvarLoad losses, downstream
n:LossPdownnoload:bus1MWNo load losses, downstream
n:LossQdownnoload:bus1MvarNo load losses, downstream
n:du_feed:bus1%Difference from voltage at start of feeder

ElmAsm basic data

b: values are worked out from the input data. Read them; they are not set.

AttributeUnitDescription
b:loc_nameยทName
b:i_motยทMotor
b:iWindGenยทWind Generator

Related

โ† ElmTerm Terminal ยท ElmAsmsc Doubly-Fed Induction Machine โ†’