ElmPvsys attributesPowerFactory PV System

Every attribute of the PowerFactory PV System (ElmPvsys): 371 input parameters and 927 result variables, with units and meaning. Copy a name into GetAttribute or SetAttribute.

What ElmPvsys is

A PV system: a photovoltaic plant and its inverter. Its power inputs are in kW and kVA, not MW.

Class
ElmPvsys, element class
PowerFactory name
PV System
Terminal suffix
:bus1 terminal
Attributes
371 input parameters and 927 result variables, in 7 calculations

Most used ElmPvsys attributes

AttributeUnitDescriptionWhere
m:P:bus1MWActive PowerLoad flow
m:Q:bus1MvarReactive PowerLoad flow
c:loading%LoadingLoad flow
pginikWActive poweractive power, kWinput data
qginikvarReactive powerinput data
sgnkVARated apparent powerrating, kVAinput data
av_modeยทLocal controllerinput data
ngnumยทparallel invertersinput data
outservยทOut of Serviceinput data

Read and write ElmPvsys in Python

import powerfactory

app = powerfactory.GetApplication()          # GetApplicationExt() from outside PowerFactory
app.GetFromStudyCase("ComLdf").Execute()      # results exist after a calculation

for pv in app.GetCalcRelevantObjects("*.ElmPvsys"):
    p_bus1 = pv.GetAttribute("m:P:bus1")          # Active Power, MW
    q_bus1 = pv.GetAttribute("m:Q:bus1")          # Reactive Power, Mvar
    print(pv.loc_name, p_bus1, q_bus1)

pv = app.GetCalcRelevantObjects("*.ElmPvsys")[0]
pv.SetAttribute("pgini", 800)                 # dispatch 800 kW
  • A result at a terminal of the pv system needs the terminal in its name: m:P:bus1, not m:P, which raises AttributeError.
  • An input parameter is read and written with or without its e: prefix: GetAttribute("outserv") and GetAttribute("e:outserv") give the same value.
  • RMS and EMT variables change over time: record them in a results object (ElmRes) to read the whole curve. GetAttribute after a run gives the value at the last time step.

ElmPvsys input parameters

The element data, as typed in GetAttribute and SetAttribute (the e: prefix is optional). Setting one changes the model.

AttributeUnitDescription
loc_nameยทName
chr_nameยทCharacteristic Name
for_nameยทForeign Key
dat_srcยทData source
timezoneยทTime zone (offset)
psutypeยทPower station unit type
sernumยทSerial Number
commissionDateยทCommissioning Date
appr_modbyยทModified by
mode_inpยทInput mode
outservยทOut of Service
ctrlStructยทControl strategy
ngnumยทparallel inverters
npnumยทPanels per inverter
mode_pgiยทModel
iLVยทConsider coincidence
indivPowerยทIndividual power generation
lvpfrecapยทPower factor
iCoincFromยทUsed coincidence definition
iopt_locยทUsed coordinates
mountยทMounting system
iopt_radยทSpecified components
iopt_gloยทGlobal irradiance data
iopt_dirยทDirect irradiance data
iopt_difยทDiffuse irradiance data
iconfedยทStatic converter-fed drive
iNoShcContrยทNo short-circuit contribution
searchBlockTrfยทExternally modelled unit transformer
iShcModelยทShort-Circuit Model
shcDeadbandยทVoltage deadband
pinputยทActive power signal
qinputยทReactive power signal
ictrltpยทModel
icurrefยทHarmonic currents referred to
iSimModelยทModel
iDelayยทdq-reference angle delay (if dq-reference signals not connected)
iUseZsrยทUse series reactor impedance, if negative sequence voltage signals are connected
iUseNegSeqAngleยทCurrent source model
ictpgยทActive Power
ictqgยทReactive Power
iOPFCPminยทMin.
iOPFCPmaxยทMax.
iOPFCQminยทMin.
iOPFCQmaxยทMax.
QtargetBaseยทBase
iInterPolยทApproximation
polyDegreeยทPolynomial degree
isVREยทGenerator usage
isCtrlPยทActive power
isCtrlQยทReactive power
isLimPmaxยทMax.
isLimPminยทMin.
isLimQmaxยทMax.
isLimQminยทMin.
isMustRunUCยทMust run
isCtrlFixedToLdfValยทFix controls to Load Flow values
is4SpinReserveยทConsider for region spinning reserve
allowConsumModeยทSeparate consumption mode
isConsCostOpยทOperating costs
discMethCostOpยทPiecewise linearisation for LP
numBreakpointsCostOpยทNumber of breakpoints
isConsCostsRedispatchยทAdditional active power redispatch costs
isConsStartUpCostยทStart-up costs
isConsShutDownCostยทShut-down costs
isConstrRampยทRamp rate constraints
isConstrUpDownยทStart-up/shut-down time constraints
isDiscreteCtrlPยทRestriction to discrete active power values
isPcurrAllowedยทAllow current active power value
consCostsRedispatchQยทAdditional reactive power redispatch costs
refValueQยทReference value for redispatch costs
refValueLdfQยทReference value for redispatch costs
refValueVยทReference value for redispatch costs
ctrlUsagePยทActive Power
ctrlUsageQยทReactive Power
isConsCostOp_QยทReactive power operating costs
iInterPol_QยทApproximation
polyDegree_QยทPolynomial degree
discMethCostOp_QยทPiecewise linearisation for LP
iestpยทEstimate active power
iestqยทEstimate reactive power
ip_ctrlยทReference machine
constrยทYear of Construction
appr_statusยทStatus
iAstabintยทA-stable integration algorithm
iopt_tdrยทUse separate droop values for over-/underexcited operation
priorityยทMerit order
fixedยทMust run
outServPzeroยทOut of service when active power is zero
nneutralยทN-Connection
isCtrlPplacementยทOptimise active power
sgnkVARated apparent power
cosnยทRated power factor
scale0ยทScaling factor
EgpvW/m^2Global irradiance, PV system
orientdegOrientation angle
tiltdegTilt angle
inveff%Efficiency factor
ghiW/m^2Global horizontal irradiance
dhiW/m^2Direct horizontal irradiance
dniW/m^2Direct normal irradiance
ktยทClearness index
TambdegCAmbient temperature
shfdirยทShading factor (direct)
shfdiffยทShading factor (diffuse)
albedoยทGround albedo
SksskVASubtransient Short-Circuit Level
SkskVATransient Short-Circuit Level
rtoxยทR to X'' ratio
KfactorยทK Factor
imaxp.u.Max. Current
uDeadbandp.u.Deadband
r0p.u.Resistance, r0
x0p.u.Reactance, x0
r2p.u.Resistance r2
x2p.u.Reactance x2
r2shcp.u.Resistance, r2
x2shcp.u.Reactance, x2
tdsssTd''
tdssTd'
SkkVASteady-State Short-Circuit Level
r1hmcp.u.Resistance, r1h
x1hmcp.u.Reactance, x1h
r2hmcp.u.Resistance, r2h
x2hmcp.u.Reactance, x2h
r0hmcp.u.Resistance, r0h
x0hmcp.u.Reactance, x0h
r1hthevp.u.Resistance, r1
x1hthevp.u.Reactance, x1
P1hrmkWActive power
Q1hrmkvarReactive power
u1hrmp.u.Positive sequence voltage
KdยทKd
KqยทKq
TdsTd
TqsTq
uk%Short circuit impedance
PcukWCopper losses
R0toR1ยทR0/R1 ratio
X0toX1ยทX0/X1 ratio
uminp.u.Switch-off threshold
uonthrp.u.Switch-on threshold
TondelaysSwitch-on delay
TdelaysDelay time constant
Kp_plluยทProportional gain
Ki_plluยทIntegration gain
T1_pllumsLow-Pass filter time constant
Kp_plliยทProportional gain
Ki_plliยทIntegration gain
T1_pllimsLow-Pass filter time constant
smoothfac%Smoothing factor
smoothfac_Q%Smoothing Factor
usetpp.u.Voltage
usp_maxp.u.Max. voltage setpoint
usp_minp.u.Min. voltage setpoint
phiinidegAngle
ddroop%Droop
q_minp.u.Min.
q_maxp.u.Max.
pmaxratfยทRating factor
Pmax_uckWMax.
Pmin_uckWMin.
KpfkW/HzPrim. frequency bias
ddroopue%Droop (underexcited)
Qfu_minkvarQ min
Qfu_maxkvarQ max
udeadbupp.u.Upper limit
udeadblowp.u.Lower limit
pf_underยทMin. power factor
pf_overยทMin. power factor
p_underkWActive power
p_overkWActive power
GPSlatdegLatitude / Northing
GPSlondegLongitude / Easting
Ikss3PFAThree-phase faults, Ik"3PF
Ikss2PFATwo-phase faults, Ik"2PF
Ikss1PFASingle-phase faults, Ik"1PF
IkPFmaxAMaximum current
IkPFminAMinimum current
r2iecp.u.Resistance, r2
x2iecp.u.Reactance, x2
r0iecp.u.Resistance, r0
x0iecp.u.Reactance, x0
QtargetRPR%Q target value
genShiftKey%Generation shift key
PminInvkWMin.
PmaxInvkWMax.
costCurtailmentUSD/kWhCosts for curtailment
penaltyCostsUSD/kWhPenalty costs
fixedCostsUSD/hFixed costs
consumCostsUSD/kWhConsumption costs
costRedispatchUpUSD/kWhUpward active power redispatch costs
costRedispatchDownUSD/kWhDownward active power redispatch costs
costRedispatchQUSD/kvarhCosts for reactive power deviation
cost_upUSDWarm-start costs
costColdStartUSDCold-start costs
coldStartTimehCold-start time
costShutDownUSDShut-down costs
limRampUpkW/hRamp-up limit
limRampDownkW/hRamp-down limit
limRampStartUpkWStart-up ramp limit
limRampShutDownkWShut-down ramp limit
minUpTimehMinimum up-time
minDownTimehMinimum down-time
targetQkvarQ target value
targetVp.u.Target voltage setpoint
fixedCostsSetpChangeQUSDFixed costs per setpoint deviation
zeroFixedCostsSetpChangeQUSDFixed costs per setpoint deviation
costRedispatchVUSD/p.u.Costs for voltage setpoint deviation
curativeLimPkWMax. curative active power deviation
curativeLimQkvarMax. curative reactive power deviation
curativeCostsUSD/kVAhCosts for curative power deviation
penaltyCosts_QUSD/kvarhPenalty costs
scaleQmin%Scaling factor (min.)
scaleQmax%Scaling factor (max.)
dpl1ยทdpl1
dpl2ยทdpl2
dpl3ยทdpl3
dpl4ยทdpl4
dpl5ยทdpl5
appr_modifยทModified
cpowerkWPower
ccostUSD/hCosts
vecBreakpointsPkWPower
vecStartUpTimes>=hDown-time
vecStartUpCostsUSDStart-up costs
vecDiscreteCtrlPvals%Valid active power values
cpower_QkvarPower
ccost_QUSD/hCosts
vecBreakpointsQkvarPower
cimRdfIdยทRDF ID
descยทDescription
sOpCommentยทOperator comment
typ_idยทTypeObject: TypPvpanel
bus1ยทTerminalObject: StaCubic
bus1nยทNeutralObject: StaCubic
pCoincDefยทIndividual coincidence definitionObject: IntCoincdef
phmcvยทHarmonic voltagesObject: TypHmcvolt,TypHmcopvolt
phmcยทHarmonic CurrentsObject: TypHmccur,TypHmcopcur
fcharr1ChaPol,ChaVec,ChaMat,ChaOpfreqFrequency-dependence, r1h(f)
fcharx1ChaPol,ChaVec,ChaMat,ChaOpfreqFrequency-dependence, x1h(f)
fcharr2ChaPol,ChaVec,ChaMat,ChaOpfreqFrequency-dependence, r2h(f)
fcharx2ChaPol,ChaVec,ChaMat,ChaOpfreqFrequency-dependence, x2h(f)
fcharr0ChaPol,ChaVec,ChaMat,ChaOpfreqFrequency-dependence, r0h(f)
fcharx0ChaPol,ChaVec,ChaMat,ChaOpfreqFrequency-dependence, x0h(f)
pFlickerยทFlicker coefficientsObject: TypFlicker
efficiencyCurveGenยทEfficiency curve (generation)Object: IntEffcurve
efficiencyCurveConsumยทEfficiency curve (consumption)Object: IntEffcurve
pOpCostCurveยทGenerator cost curveObject: IntCostcurvegen
doc_idยทAdditional Data
pOwnerยทOwnerObject: ElmOwner
pOperatorยทOperatorObject: ElmOperator
pSubModelยทSubmodelObject: ElmSubmodel
pQlimTypeยทCapability curveObject: IntQlim
pQPcurveยทQ(P)-CurveObject: IntQpcurve
pQVcurveยทQ(V)-CurveObject: IntQvcurve
pBMUยทVirtual power plantObject: ElmBmu
pGRStochStoGenStochastic Model
bus1_barยทTerminal
bus1n_barยทNeutral
cpZoneยทZoneObject: ElmZone
cpAreaยทAreaObject: ElmArea
pginikWActive power
qginikvarReactive power
cosginiยทPower factor
pf_recapยทPower factor
InomkANominal current
cPmaxLVkWActive power, P, with coincidence
cSmaxLVkVAApparent power, S, with coincidence
cPsumLVkWActive power, P, theoretical
cSsumLVkVAApparent power, S, theoretical
cGPSlatdegLatitude
cGPSlondegLongitude
cTimezoneยทTime zone (offset)
orient_adegOrientation angle (act.)
tilt_adegTilt angle (act.)
ghi_aW/m^2Global horizontal irradiance (act.)
dhi_aW/m^2Direct horizontal irradiance (act.)
dni_aW/m^2Direct normal irradiance (act.)
kt_aยทClearness index (act.)
Tamb_adegCAmb. temp. (act.)
shfdir_aยทShading factor (dir.) (act.)
shfdiff_aยทShading factor (diff.) (act.)
albedo_aยทAlbedo (act.)
pblocktrfยทUnit transformerObject: ElmTr2
IkssASubtransient Short-Circuit Current
IksATransient Short-Circuit Current
xtorยทX'' to R ratio
IkASteady-state shc. current
cTypHmcยทType of harmonic sources
IratedkARated Current
R1hmcOhmResistance, R1h
X1hmcOhmReactance, X1h
R2hmcOhmResistance, R2h
X2hmcOhmReactance, X2h
R0hmcOhmResistance, R0h
X0hmcOhmReactance, X0h
r1hp.u.Resistance, r1h
x1hp.u.Reactance, x1h
r2hp.u.Resistance, r2h
x2hp.u.Reactance, x2h
r0hp.u.Resistance, r0h
x0hp.u.Reactance, x0h
islandOperRMSยทEnable operation if part of an isolated area
islandOperEMTยทEnable operation if part of an isolated area
avgCostsUSD/kWhAverage costs
costRedispatchPUSD/kWhCosts for active power deviation
cStorageยทStorage modelObject: ElmStorage
cIsMustRunUCยทMust run
efficiencyLPgenยทUsed efficiency (generation)
efficiencyLPconsumยทUsed efficiency (consumption)
allowGenModeยทSeparate generation mode
PminInvPUp.u.Min.
PmaxInvPUp.u.Max.
avgCostsUcUSD/kWhAverage costs
cfixedCostsUSD/hFixed costs
limRampUpPUp.u./hRamp-up limit
limRampDownPUp.u./hRamp-down limit
limRampStartUpPUp.u.Start-up ramp limit
limRampShutDownPUp.u.Shut-down ramp limit
cIsDiscreteCtrlPยทRestriction to discrete active power values
cVecDiscreteCtrlPvals%Valid active power values
cIsPcurrAllowedยทAllow current active power value
cCtrlUsagePยทActive Power
cCtrlUsageQยทReactive Power
cCurativeLimP_PUp.u.Max. curative active power deviation
cCurativeLimQ_PUp.u.Max. curative reactive power deviation
avgCostsUc_QUSD/kvarhAverage costs
avgCostsUc_posQUSD/kvarhAverage costs (pos. range)
avgCostsUc_negQUSD/kvarhAverage costs (neg. range)
av_modeยทLocal controller
c_pseccยทExternal secondary controllerObject: ElmSecctrl
c_pstacยทExternal station controllerObject: ElmStactrl
qdslCtrlยทQuasi-dynamic modelObject: ElmQdsl
c_pCtrlHVยทControlled HV-busbarObject: ElmTerm
UctrlkVHV-Voltage setpoint
cQ_minkvarMinimum
cQ_maxkvarMaximum
PnomkWPr(rated)
P_maxkWMax.
Pmax_ucPUp.u.Max.
Pmin_ucPUp.u.Min.
u0qvrefp.u.Reference voltage
ddroopoe%Droop (overexcited)
dispatchยทGenerator dispatch
Qmin_akvarQmin(act.)
Qmax_akvarQmax(act.)
Pmin_akWPmin(act.)
Pmax_akWPmax(act.)
c_pmodยทModelObject: ElmComp
phtechยทTechnology
pgini_akWActive power (act.)
qgini_akvarReactive power (act.)
sgini_akVAApparent power (act.)
cosgini_aยทPower factor (act.)
pf_recap_aยทPower factor ind/cap (act.)
scale0_aยทScaling factor(act.)
PngrelkWBased on rated active power (Pr)
FAYh/aFull availability expectancy
FOEh/aForced outage expectancy
EDSh/aExpectancy of derated states
Egh_aW/m^2Global horizontaliIrradiance (act.)
Ebh_aW/m^2Direct horizontal irradiance (act.)
Edh_aW/m^2Diffuse horizontal irradiance (act.)
Egpv_aW/m^2Global irradiance, PV panel (act.)
Ebpv_aW/m^2Direct irradiance, PV panel (act.)
Edpv_aW/m^2Diffuse irradiance, PV panel (act.)
Erpv_aW/m^2Reflected irradiance, PV panel (act.)
RelEff_aยทRelative efficiency (act.)
ktc_aW/m^2Calculated clearness index
solalt_adegSolar altitude angle (act.)
anginc_adegAngle of incidence (act.)

ElmPvsys load flow results

Read after ComLdf with GetAttribute. m: currents, voltages and powers, c: calculation parameter, n: bus result at a terminal, s: signal (state or model variable).

AttributeUnitDescription
m:urnet:bus1p.u.Voltage, Real Part, referred to network
m:uinet:bus1p.u.Voltage, Imaginary Part, referred to network
m:u1r:bus1p.u.Positive-Sequence-Voltage, Real Part
m:u1i:bus1p.u.Positive-Sequence-Voltage, Imaginary Part
m:u1:bus1p.u.Positive-Sequence-Voltage, Magnitude
m:U1:bus1kVLine-Ground Positive-Sequence-Voltage, Magnitude
m:U1l:bus1kVLine-Line Positive-Sequence-Voltage, Magnitude
m:phiu1:bus1degPositive-Sequence-Voltage, Angle
m:irnet:bus1p.u.Current, Real Part, referred to network
m:iinet:bus1p.u.Current, Imaginary Part, referred to network
m:inet:bus1p.u.Current, Magnitude, referred to network
m:I:bus1kACurrent, Magnitude
m:phii:bus1degCurrent, Angle
m:i1r:bus1p.u.Positive-Sequence Current, Real Part
m:i1i:bus1p.u.Positive-Sequence Current, Imaginary Part
m:i1:bus1p.u.Positive-Sequence Current, Magnitude
m:I1:bus1kAPositive-Sequence Current, Magnitude
m:phii1:bus1degPositive-Sequence Current, Angle
m:P:bus1MWActive Power
m:Q:bus1MvarReactive Power
m:S:bus1MVAApparent Power
m:cosphi:bus1ยทPower Factor
m:tanphi:bus1ยทtan(phi)
m:Psum:bus1MWTotal Active Power
m:Qsum:bus1MvarTotal Reactive Power
m:Ssum:bus1MVATotal Apparent Power
m:cosphisum:bus1ยทTotal Power Factor
m:tanphisum:bus1ยทTotal tan(phi)
m:i1P:bus1p.u.Positive-Sequence Active Current
m:i1Q:bus1p.u.Positive-Sequence Reactive Current
m:I1P:bus1kAPositive-Sequence Active Current
m:I1Q:bus1kAPositive-Sequence Reactive Current
m:ur:bus1p.u.Voltage, Real Part
m:ui:bus1p.u.Voltage, Imaginary Part
m:u:bus1p.u.Voltage, Magnitude
m:ir:bus1p.u.Current, Real Part
m:ii:bus1p.u.Current, Imaginary Part
m:i:bus1p.u.Current, Magnitude
m:phiui:bus1degAngle between Voltage and Current
m:phiu1i1:bus1degAngle between Voltage and Current in positive sequence system
m:Tfct:bus1sFault Clearing Time
m:Brkload:bus1%Breaker Loading
m:Spu:bus1MVA/p.u.Apparent Power per p.u. Voltage
m:urnet:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage, Real Part, referred to network
m:uinet:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage, Imaginary Part, referred to network
m:u0:bus1p.u.Zero-Sequence-Voltage, Magnitude
m:phiu0:bus1degZero-Sequence-Voltage, Angle
m:u2:bus1p.u.Negative-Sequence-Voltage, Magnitude
m:phiu2:bus1degNegative-Sequence-Voltage, Angle
m:irnet:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, Real Part, referred to network
m:iinet:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, Imaginary Part, referred to network
m:inet:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, Magnitude, referred to network
m:I:bus1:Aper phase :A, :B, :C, unbalanced onlykAPhase Current, Magnitude
m:phii:bus1:Aper phase :A, :B, :C, unbalanced onlydegPhase Current, Angle
m:i0r:bus1p.u.Zero-Sequence Current, Real Part
m:i0i:bus1p.u.Zero-Sequence Current, Imaginary Part
m:i0:bus1p.u.Zero-Sequence Current, Magnitude
m:I0:bus1kAZero-Sequence Current, Magnitude
m:I0x3:bus1kA3*I0
m:phii0:bus1degZero-Sequence Current, Angle
m:i2r:bus1p.u.Negative-Sequence Current, Real Part
m:i2i:bus1p.u.Negative-Sequence Current, Imaginary Part
m:i2:bus1p.u.Negative-Sequence Current, Magnitude
m:I2:bus1kANegative-Sequence Current, Magnitude
m:phii2:bus1degNegative-Sequence Current, Angle
m:ubfacI:bus1%Current Unbalance Factor
m:ubfacS:bus1%Power Unbalance Factor
m:P:bus1:Aper phase :A, :B, :C, unbalanced onlyMWActive Power
m:Q:bus1:Aper phase :A, :B, :C, unbalanced onlyMvarReactive Power
m:S:bus1:Aper phase :A, :B, :C, unbalanced onlyMVAApparent Power
m:cosphi:bus1:Aper phase :A, :B, :C, unbalanced onlyยทPower Factor
m:tanphi:bus1:Aper phase :A, :B, :C, unbalanced onlyยทtan(phi)
m:Pln:bus1:Aper phase :A, :B, :C, unbalanced onlyMWActive Power (Line-Neutral)
m:Qln:bus1:Aper phase :A, :B, :C, unbalanced onlyMvarReactive Power (Line-Neutral)
m:P1:bus1MWPositive Sequence Active Power
m:Q1:bus1MvarPositive Sequence Reactive Power
m:P2:bus1MWNegative Sequence Active Power
m:Q2:bus1MvarNegative Sequence Reactive Power
m:P0:bus1MWZero Sequence Active Power
m:Q0:bus1MvarZero Sequence Reactive Power
m:i2P:bus1p.u.Negative-Sequence Active Current
m:i2Q:bus1p.u.Negative-Sequence Reactive Current
m:I2P:bus1kANegative-Sequence Active Current
m:I2Q:bus1kANegative-Sequence Reactive Current
m:ur:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage, Real Part
m:ui:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage, Imaginary Part
m:u:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage, Magnitude
m:ir:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, Real Part
m:ii:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, Imaginary Part
m:i:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, Magnitude
m:phiui:bus1:Aper phase :A, :B, :C, unbalanced onlydegAngle between Voltage and Current
m:phiu0i0:bus1degAngle between Voltage and Current in zero-sequence system
m:phiu2i2:bus1degAngle between Voltage and Current in negative sequence system
m:TfctPh:bus1:Aper phase :A, :B, :C, unbalanced onlysFault Clearing Time
m:BrkloadPh:bus1:Aper phase :A, :B, :C, unbalanced only%Breaker Loading
c:sgnnMVATotal rated apparent power (ngnum*sgn)
c:cosnยทNominal-Power factor
c:pMWTotal Active Power
c:qMvarTotal Reactive Power
c:PnomMWTotal Nominal Active power
c:c2ยทVoltage Coefficient (uknom/ugn)
c:uinip.u.Voltage Setpoint for PV and Slack
c:phiiniยทInitial Angle
c:phirelrefradRelative reference angle
c:loading%Loading
c:iPowerOnยทFlag
c:QminMvarLower limit of reactive power
c:QmaxMvarUpper limit of reactive power
c:QspareleadMvarQ spare lead
c:QsparelagMvarQ spare lag
c:i_qlimยทReactive power limit reached
c:i_vlimยทVoltage setpoint limit reached
c:PminMWLower limit of active power
c:PmaxMWUpper limit of active power
c:i_plimยทActive power limit reached
c:smMVAComplex Power
c:u1p.u.Internal
c:Kpp.u.Active Power Participation
c:Kqp.u.Reactive Power Participation
c:KpfMW/HzFrequency Bias
c:iRefElementยทReference Element
c:NnomยทNumber of parallel units
c:zonewscaleยทWind generation zone scaling factor
c:PmismMWActive Power Mismatch
c:nCtrlIterยทNo. of CTRL-iterations
c:PlossMWLosses (total)
c:QlossMvarReactive-Losses (total)
c:PlossldMWLosses (load)
c:QlossldMvarReactive-Losses (load)
c:PlossnldMWLosses (no load)
c:QlossnldMvarReactive-Losses (no load)
c:SnomMVANom. Apparent Power (1 mach.)
n:ur:bus1p.u.Voltage, Real Part
n:ui:bus1p.u.Voltage, Imaginary Part
n:u:bus1p.u.Voltage, Magnitude
n:upc:bus1%Voltage, Magnitude
n:du:bus1%Voltage Deviation
n:U:bus1kVLine-Ground Voltage, Magnitude
n:phiu:bus1degVoltage, Angle
n:phiurel:bus1degVoltage, Relative Angle
n:Ul:bus1kVLine-Line Voltage, Magnitude
n:u1:bus1p.u.Voltage, Magnitude
n:u1pc:bus1%Voltage, Magnitude
n:u1r:bus1p.u.Positive-Sequence Voltage, Real Part
n:u1i:bus1p.u.Positive-Sequence Voltage, Imaginary Part
n:Pgen:bus1MWGeneration, Active Power
n:Qgen:bus1MvarGeneration, Reactive Power
n:Pmot:bus1MWMotor Load, Active Power
n:Qmot:bus1MvarMotor Load, Reactive Power
n:Pload:bus1MWGeneral Load, Active Power
n:Qload:bus1MvarGeneral Load, Reactive Power
n:Pcomp:bus1MWCompensation (Losses)
n:Qcomp:bus1MvarCompensation
n:Pnet:bus1MWExternal Networks, Active Power
n:Qnet:bus1MvarExternal Networks, Reactive Power
n:Pflow:bus1MWPower Flow, Active Power
n:Qflow:bus1MvarPower Flow, Reactive Power
n:Pout:bus1MWOutgoing Flow, Active Power
n:Qout:bus1MvarOutgoing Power, Reactive Power
n:Sout:bus1MVAOutgoing Power, Apparent Power
n:cosphiout:bus1ยทOutgoing Power, Power Factor
n:Pbalance:bus1MWActive Power Balance (=0)
n:Qbalance:bus1MvarReactive Power Balance (=0)
n:LossPdown:bus1MWLosses, downstream
n:LossQdown:bus1MvarLosses, downstream (Reactive Power)
n:LossPdownload:bus1MWLoad losses, downstream
n:LossQdownload:bus1MvarLoad losses, downstream
n:LossPdownnoload:bus1MWNo load losses, downstream
n:LossQdownnoload:bus1MvarNo load losses, downstream
n:du_feed:bus1%Difference from voltage at start of feeder
n:ur:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Ground Voltage, Real Part
n:ui:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Ground Voltage, Imaginary Part
n:u:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Ground Voltage, Magnitude
n:upc:bus1:Aper phase :A, :B, :C, unbalanced only%Line-Ground Voltage, Magnitude
n:du:bus1:Aper phase :A, :B, :C, unbalanced only%Voltage Deviation
n:U:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Ground Voltage, Magnitude
n:phiu:bus1:Aper phase :A, :B, :C, unbalanced onlydegLine-Ground Voltage, Angle
n:ul:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Line Voltage, Magnitude
n:ulpc:bus1:Aper phase :A, :B, :C, unbalanced only%Line-Line Voltage, Magnitude
n:Ul:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Line Voltage, Magnitude
n:phiul:bus1:Aper phase :A, :B, :C, unbalanced onlydegLine-Line Voltage, Angle
n:u0:bus1p.u.Zero-Sequence Voltage, Magnitude
n:U0:bus1kVZero-Sequence Voltage, Magnitude
n:U0x3:bus1kV3*U0
n:phiu0:bus1degZero-Sequence Voltage, Angle
n:U1:bus1kVLine-Ground Positive-Sequence Voltage, Magnitude
n:phiu1:bus1degPositive-Sequence Voltage, Angle
n:u2:bus1p.u.Negative-Sequence Voltage, Magnitude
n:U2:bus1kVLine-Ground Negative-Sequence Voltage, Magnitude
n:phiu2:bus1degNegative-Sequence Voltage, Angle
n:U1l:bus1kVLine-Line Positive-Sequence Voltage, Magnitude
n:U2l:bus1kVLine-Line Negative-Sequence Voltage, Magnitude
n:uln:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Neutral Voltage, Magnitude
n:Uln:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Neutral Voltage, Magnitude
n:phiuln:bus1:Aper phase :A, :B, :C, unbalanced onlydegLine-Neutral Voltage, Angle
n:un:bus1p.u.Neutral-Ground Voltage, Magnitude
n:Un:bus1kVNeutral-Ground Voltage, Magnitude
n:phiun:bus1degNeutral-Ground Voltage, Angle
n:upht:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Technology dependent Voltage, Magnitude
n:Upht:bus1:Aper phase :A, :B, :C, unbalanced onlykVPhase Technology dependent Voltage, Magnitude
n:um:bus1p.u.Average-Voltage, Magnitude
n:Um:bus1kVAverage-Voltage, Magnitude
n:uphtmin:bus1p.u.Minimum of Phase Technology dependent Voltage, Magnitude
n:uphtmax:bus1p.u.Maximum of Phase Technology dependent Voltage, Magnitude
n:ubfac:bus1%Unbalance Factor
s:psetMWActive Power Setpoint
s:qsetMvarReactive Power Setpoint
s:dFinHzFrequency Deviation
s:phisetradVoltage Angle Setpoint
s:i2r_setp.u.Negative sequence current setpoint, Real Part
s:i2i_setp.u.Negative sequence current setpoint, Imaginary Part

ElmPvsys short-circuit results

Read after ComShc with GetAttribute. m: currents, voltages and powers, c: calculation parameter, n: bus result at a terminal.

AttributeUnitDescription
m:I:bus1kAShort-Circuit Current, Magnitude
m:phii:bus1degPhase Current, Angle
m:i1:bus1p.u.Positive-Sequence Current, Magnitude
m:I1:bus1kAPositive-Sequence Current, Magnitude
m:phii1:bus1degPositive-Sequence Current, Angle
m:P:bus1MWActive Power
m:Q:bus1MvarReactive Power
m:i1P:bus1p.u.Positive-Sequence Active Current
m:i1Q:bus1p.u.Positive-Sequence Reactive Current
m:I1P:bus1kAPositive-Sequence Active Current
m:I1Q:bus1kAPositive-Sequence Reactive Current
m:phiui:bus1degAngle between Voltage and Current
m:phiu1i1:bus1degAngle between Voltage and Current in Positive-Sequence System
m:Tfct:bus1sFault Clearing Time
m:Ikss:bus1kAInitial Short-Circuit Current
m:ikss:bus1p.u.Initial Short-Circuit Current, Magnitude
m:Skss:bus1MVAInitial Short-Circuit Power
m:ip:bus1kAPeak Short-Circuit Current
m:maxIkss:bus1kAMax. Initial Short-Circuit Current
m:maxip:bus1kAMax. Peak Short-Circuit Current
m:maxIth:bus1kAMax. Thermal equivalent Short-Circuit Current
m:maxIb:bus1kAMax. Breaking Current
m:R:bus1OhmFault Impedance, Real Part
m:X:bus1OhmFault Impedance, Imaginary Part
m:Z:bus1OhmFault Impedance, Magnitude
m:phiz:bus1degFault Impedance, Angle
m:Rs:bus1OhmSource Impedance, Real Part
m:Xs:bus1OhmSource Impedance, Imaginary Part
m:Zs:bus1OhmSource Impedance, Magnitude
m:phizs:bus1degSource Impedance, Angle
m:BrkIpload:bus1%Breaker Loading (peak)
m:Ib:bus1kAShort-Circuit Breaking Current
m:Sb:bus1MVAShort-Circuit Breaking Power
m:Ith:bus1kAThermal equivalent Short-Circuit Current
m:zSbase:bus1p.u.Fault Impedance, Magnitude
m:XtoR:bus1ยทX/R ratio
m:cosphiui:bus1ยทcosphi
m:BrkIbload:bus1%Breaker Loading (breaking)
m:BrkmaxIb:bus1kAMax. Breaking Current (breaker time)
m:Ik:bus1kASteady-State Short-Circuit Current
m:I:bus1:Aper phase :A, :B, :C, unbalanced onlykAShort-Circuit Current, Magnitude
m:phii:bus1:Aper phase :A, :B, :C, unbalanced onlydegPhase Current, Angle
m:I0:bus1kAZero-Sequence Current, Magnitude
m:I0x3:bus1kA3*I0
m:phii0:bus1degZero-Sequence Current, Angle
m:I2:bus1kANegative-Sequence Current, Magnitude
m:phii2:bus1degNegative-Sequence Current, Angle
m:P:bus1:Aper phase :A, :B, :C, unbalanced onlyMWActive Power
m:Q:bus1:Aper phase :A, :B, :C, unbalanced onlyMvarReactive Power
m:Psum:bus1MWTotal Active Power
m:Qsum:bus1MvarTotal Reactive Power
m:cosphisum:bus1ยทTotal Power Factor
m:P2:bus1MWP2
m:Q2:bus1MvarQ2
m:P0:bus1MWP0
m:phiui:bus1:Aper phase :A, :B, :C, unbalanced onlydegAngle between Voltage and Current
m:phiu0i0:bus1degAngle between Voltage and Current in Zero-Sequence System
m:phiu2i2:bus1degAngle between Voltage and Current in Negative-Sequence System
m:TfctPh:bus1:Aper phase :A, :B, :C, unbalanced onlysFault Clearing Time
m:Ikss:bus1:Aper phase :A, :B, :C, unbalanced onlykAInitial Short-Circuit Current
m:ikss:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Initial Short-Circuit Current, Magnitude
m:Skss:bus1:Aper phase :A, :B, :C, unbalanced onlyMVAInitial Short-Circuit Power
m:Skssx3:bus1:Aper phase :A, :B, :C, unbalanced onlyMVA3*Initial Short-Circuit Power
m:ip:bus1:Aper phase :A, :B, :C, unbalanced onlykAPeak Short-Circuit Current
m:Z:bus1:Aper phase :A, :B, :C, unbalanced onlyOhmFault Impedance, Magnitude
m:phiz:bus1:Aper phase :A, :B, :C, unbalanced onlydegFault Impedance, Angle
m:Zl:bus1:Aper phase :A, :B, :C, unbalanced onlyOhmLine-Line Fault Impedance, Magnitude
m:phizl:bus1:Aper phase :A, :B, :C, unbalanced onlydegLine-Line Fault Impedance, Angle
m:Z0:bus1OhmZero-Sequence Fault Impedance, Magnitude
m:phiz0:bus1degZero-Sequence Fault Impedance, Angle
m:z0Sbase:bus1p.u.Zero-Sequence Fault Impedance, Magnitude
m:cosphiu1i1:bus1ยทPositive-Sequence cosphi
m:I0x3watt:bus1kAEarth-Fault Residual Current
m:I0x3var:bus1kACapacitive Earth-Fault Current
m:Q0cap:bus1MvarQ0 capacitive
m:Rfrel:bus1OhmRelay Impedance, Real Part
m:Xfrel:bus1OhmRelay Impedance, Imaginary Part
m:Zfrel:bus1OhmRelay Impedance, Magnitude
m:phizfrel:bus1degRelay Impedance, Angle
m:Zf:bus1OhmMeas. Fault Impedance, Magnitude
m:phizf:bus1degMeas. Fault Impedance, Angle
c:uinip.u.Internal positive-sequence voltage
c:z1p.u.Positive-sequence impedance
c:imaxp.u.Max. current
c:Zwdp.u.Impedance of doubly-fed asynchronous generator
c:z0p.u.Zero-sequence impedance
c:z2p.u.Negative-sequence impedance
c:KfactorยทK Factor
c:icurlimยทCurrent limited reached
n:ur:bus1p.u.Voltage, Real Part
n:ui:bus1p.u.Voltage, Imaginary Part
n:u:bus1p.u.Voltage, Magnitude
n:upc:bus1%Voltage, Magnitude
n:du:bus1%Voltage Deviation
n:U:bus1kVLine-Ground Voltage, Magnitude
n:phiu:bus1degVoltage, Angle
n:Ul:bus1kVLine-Line Voltage, Magnitude
n:u1:bus1p.u.Voltage, Magnitude
n:u1pc:bus1%Voltage, Magnitude
n:u1r:bus1p.u.Positive-Sequence Voltage, Real Part
n:u1i:bus1p.u.Positive-Sequence Voltage, Imaginary Part
n:Ikss:bus1kAInitial Short-Circuit Current
n:I:bus1kAShort-Circuit Current
n:phii:bus1degPhase Current, Angle
n:Skss:bus1MVAInitial Short-Circuit Power
n:ip:bus1kAPeak Short-Circuit Current
n:Ib:bus1kAShort-Circuit Breaking Current
n:Sb:bus1MVAShort-Circuit Breaking Power
n:idc:bus1kADecaying Component
n:Ith:bus1kAThermal equivalent Short-Circuit Current
n:R1toX1:bus1ยทR1/X1 ratio (Zk")
n:X1toR1:bus1ยทX1/R1 ratio (Zk")
n:R:bus1OhmShort-Circuit Impedance, Real Part
n:X:bus1OhmShort-Circuit Impedance, Imaginary Part
n:Z:bus1OhmShort-Circuit Impedance, Magnitude
n:phiz:bus1degShort-Circuit Impedance, Angle
n:urpref:bus1p.u.Pre-fault Voltage, Real Part
n:uipref:bus1p.u.Pre-fault Voltage, Imaginary Part
n:upref:bus1p.u.Pre-fault Voltage, Magnitude
n:uprefpc:bus1%Pre-fault Voltage, Magnitude
n:Upref:bus1kVLine-Ground Pre-fault Voltage, Magnitude
n:Ulpref:bus1kVLine-Line Pre-fault Voltage, Magnitude
n:phiupref:bus1degPre-fault Voltage, Angle
n:phiui:bus1degAngle between Voltage and Current
n:Ithload:bus1%Loading, Thermal equivalent Current
n:Ipload:bus1%Loading, Peak Short-Circuit Current
n:Ithrtk:bus1kARated Short-Time Current (Tk)
n:XtoR:bus1ยทX/R ratio (peak)
n:RtoX:bus1ยทR/X ratio (peak)
n:XtoR_b:bus1ยทX/R ratio (dc)
n:RtoX_b:bus1ยทR/X ratio (dc)
n:fctof_b:bus1ยทEquivalent Frequency fc/f (dc)
n:rSbase:bus1p.u.Short-Circuit Impedance, Real Part
n:xSbase:bus1p.u.Short-Circuit Impedance, Imaginary Part
n:zSbase:bus1p.u.Short-Circuit Impedance, Magnitude
n:Tn:bus1msGrid Time Constant
n:Ik:bus1kASteady-State Short-Circuit Current
n:cfac:bus1ยทVoltage Factor
n:Iasy:bus1kAAsymmetrical Breaking Current
n:ur:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Ground Voltage, Real Part
n:ui:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Ground Voltage, Imaginary Part
n:u:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Ground Voltage, Magnitude
n:upc:bus1:Aper phase :A, :B, :C, unbalanced only%Line-Ground Voltage, Magnitude
n:du:bus1:Aper phase :A, :B, :C, unbalanced only%Voltage Deviation
n:U:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Ground Voltage, Magnitude
n:phiu:bus1:Aper phase :A, :B, :C, unbalanced onlydegLine-Ground Voltage, Angle
n:ul:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Line Voltage, Magnitude
n:ulpc:bus1:Aper phase :A, :B, :C, unbalanced only%Line-Line Voltage, Magnitude
n:Ul:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Line Voltage, Magnitude
n:phiul:bus1:Aper phase :A, :B, :C, unbalanced onlydegLine-Line Voltage, Angle
n:u0:bus1p.u.Zero-Sequence Voltage, Magnitude
n:U0:bus1kVZero-Sequence Voltage, Magnitude
n:U0x3:bus1kV3*U0
n:phiu0:bus1degZero-Sequence Voltage, Angle
n:U1:bus1kVLine-Ground Positive-Sequence Voltage, Magnitude
n:phiu1:bus1degPositive-Sequence Voltage, Angle
n:u2:bus1p.u.Negative-Sequence Voltage, Magnitude
n:U2:bus1kVLine-Ground Negative-Sequence Voltage, Magnitude
n:phiu2:bus1degNegative-Sequence Voltage, Angle
n:U1l:bus1kVLine-Line Positive-Sequence Voltage, Magnitude
n:U2l:bus1kVLine-Line Negative-Sequence Voltage, Magnitude
n:uln:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Neutral Voltage, Magnitude
n:Uln:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Neutral Voltage, Magnitude
n:phiuln:bus1:Aper phase :A, :B, :C, unbalanced onlydegLine-Neutral Voltage, Angle
n:un:bus1p.u.Neutral-Ground Voltage, Magnitude
n:Un:bus1kVNeutral-Ground Voltage, Magnitude
n:phiun:bus1degNeutral-Ground Voltage, Angle
n:upht:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Technology dependent Voltage, Magnitude
n:Upht:bus1:Aper phase :A, :B, :C, unbalanced onlykVPhase Technology dependent Voltage, Magnitude
n:Ikss:bus1:Aper phase :A, :B, :C, unbalanced onlykAInitial Short-Circuit Current
n:I:bus1:Aper phase :A, :B, :C, unbalanced onlykAShort-Circuit Current
n:phii:bus1:Aper phase :A, :B, :C, unbalanced onlydegPhase Current, Angle
n:Skss:bus1:Aper phase :A, :B, :C, unbalanced onlyMVAInitial Short-Circuit Power
n:Skssx3:bus1:Aper phase :A, :B, :C, unbalanced onlyMVA3*Initial Short-Circuit Power
n:ip:bus1:Aper phase :A, :B, :C, unbalanced onlykAPeak Short-Circuit Current
n:Ib:bus1:Aper phase :A, :B, :C, unbalanced onlykAShort-Circuit Breaking Current
n:Sb:bus1:Aper phase :A, :B, :C, unbalanced onlyMVAShort-Circuit Breaking Power
n:Ith:bus1:Aper phase :A, :B, :C, unbalanced onlykAThermal equivalent Short-Circuit Current
n:Ithmax:bus1kAMax. Thermal equivalent Short-Circuit Current
n:R0:bus1OhmZero-Sequence Impedance, Real Part
n:X0:bus1OhmZero-Sequence Impedance, Imaginary Part
n:Z0:bus1OhmZero-Sequence Impedance, Magnitude
n:phiz0:bus1degZero-Sequence Impedance, Angle
n:r0Sbase:bus1p.u.Zero-Sequence Impedance, Real Part
n:x0Sbase:bus1p.u.Zero-Sequence Impedance, Imaginary Part
n:z0Sbase:bus1p.u.Zero-Sequence Impedance, Magnitude
n:R1:bus1OhmPositive-Sequence Impedance, Real Part
n:X1:bus1OhmPositive-Sequence Impedance, Imaginary Part
n:Z1:bus1OhmPositive-Sequence Impedance, Magnitude
n:phiz1:bus1degPositive-Sequence Impedance, Angle
n:r1Sbase:bus1p.u.Positive-Sequence Impedance, Real Part
n:x1Sbase:bus1p.u.Positive-Sequence Impedance, Imaginary Part
n:z1Sbase:bus1p.u.Positive-Sequence Impedance, Magnitude
n:R2:bus1OhmNegative-Sequence Impedance, Real Part
n:X2:bus1OhmNegative-Sequence Impedance, Imaginary Part
n:Z2:bus1OhmNegative-Sequence Impedance, Magnitude
n:phiz2:bus1degNegative-Sequence Impedance, Angle
n:r2Sbase:bus1p.u.Negative-Sequence Impedance, Real Part
n:x2Sbase:bus1p.u.Negative-Sequence Impedance, Imaginary Part
n:z2Sbase:bus1p.u.Negative-Sequence Impedance, Magnitude
n:R0toX0:bus1ยทR0/X0 ratio (Zk")
n:X0toR0:bus1ยทX0/R0 ratio (Zk")
n:R2toX2:bus1ยทR2/X2 ratio (Zk")
n:X2toR2:bus1ยทX2/R2 ratio (Zk")
n:R:bus1:Aper phase :A, :B, :C, unbalanced onlyOhmNetwork Resistance, Line-Ground
n:X:bus1:Aper phase :A, :B, :C, unbalanced onlyOhmNetwork Reactance, Line-Ground
n:Z:bus1:Aper phase :A, :B, :C, unbalanced onlyOhmNetwork Impedance, Line-Ground
n:phiz:bus1:Aper phase :A, :B, :C, unbalanced onlydegAngle of Network Impedance, Line-Ground
n:Rl:bus1:Aper phase :A, :B, :C, unbalanced onlyOhmNetwork Resistance, Line-Line
n:Xl:bus1:Aper phase :A, :B, :C, unbalanced onlyOhmNetwork Reactance, Line-Line
n:Zl:bus1:Aper phase :A, :B, :C, unbalanced onlyOhmNetwork Impedance, Line-Line
n:phizl:bus1:Aper phase :A, :B, :C, unbalanced onlydegAngle of Network Impedance, Line-Line
n:Rln:bus1:Aper phase :A, :B, :C, unbalanced onlyOhmNetwork Resistance, Line-Neutral
n:Xln:bus1:Aper phase :A, :B, :C, unbalanced onlyOhmNetwork Reactance, Line-Neutral
n:Zln:bus1:Aper phase :A, :B, :C, unbalanced onlyOhmNetwork Impedance, Line-Neutral
n:phizln:bus1:Aper phase :A, :B, :C, unbalanced onlydegAngle of Network Impedance, Line-Neutral
n:Rn:bus1OhmNetwork Resistance, Neutral
n:Xn:bus1OhmNetwork Reactance, Neutral
n:Zn:bus1OhmNetwork Impedance, Neutral
n:phizn:bus1degAngle of Network Impedance, Neutral
n:eff:bus1:Aper phase :A, :B, :C, unbalanced onlyยทEarth Fault Factor
n:X0toX1:bus1ยทX0/X1
n:In:bus1kANeutral Current, Magnitude
n:phiin:bus1degNeutral Current, Angle
n:I0:bus1kAZero-Sequence Current, Magnitude
n:I0x3:bus1kA3*I0
n:phii0:bus1degZero-Sequence Current, Angle
n:I1:bus1kAPositive-Sequence Current, Magnitude
n:phii1:bus1degPositive-Sequence Current, Angle
n:I2:bus1kANegative-Sequence Current, Magnitude
n:phii2:bus1degNegative-Sequence Current, Angle
n:urpref:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Pre-fault Voltage, Real Part
n:uipref:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Pre-fault Voltage, Imaginary Part
n:upref:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Pre-fault Voltage, Magnitude
n:uprefpc:bus1:Aper phase :A, :B, :C, unbalanced only%Pre-fault Voltage, Magnitude
n:Upref:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Ground Pre-fault Voltage, Magnitude
n:Ulpref:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Line Pre-fault Voltage, Magnitude
n:phiupref:bus1:Aper phase :A, :B, :C, unbalanced onlydegPre-fault Voltage, Angle
n:phiui:bus1:Aper phase :A, :B, :C, unbalanced onlydegAngle between Voltage and Current
n:phiu1i1:bus1degAngle between Voltage and Current in positive sequence system
n:phiu2i2:bus1degAngle between Voltage and Current in negative sequence system
n:phiu0i0:bus1degAngle between Voltage and Current in zero-sequence system
n:Ik:bus1:Aper phase :A, :B, :C, unbalanced onlykASteady-State Short-Circuit Current
n:in:bus1p.u.Neutral Current, Magnitude
n:i0r:bus1p.u.Zero-Sequence Current, Real Part
n:i0i:bus1p.u.Zero-Sequence Current, Imaginary Part
n:i0:bus1p.u.Zero-Sequence Current, Magnitude
n:i1r:bus1p.u.Positive-Sequence Current, Real Part
n:i1i:bus1p.u.Positive-Sequence Current, Imaginary Part
n:i1:bus1p.u.Positive-Sequence Current, Magnitude
n:i2r:bus1p.u.Negative-Sequence Current, Real Part
n:i2i:bus1p.u.Negative-Sequence Current, Imaginary Part
n:i2:bus1p.u.Negative-Sequence Current, Magnitude

ElmPvsys rms simulation results

Read after ComInc (RMS) with GetAttribute. m: currents, voltages and powers, c: calculation parameter, n: bus result at a terminal, s: signal (state or model variable).

AttributeUnitDescription
m:urnet:bus1p.u.Voltage, Real Part, referred to network
m:uinet:bus1p.u.Voltage, Imaginary Part, referred to network
m:u1r:bus1p.u.Positive-Sequence-Voltage, Real Part
m:u1i:bus1p.u.Positive-Sequence-Voltage, Imaginary Part
m:u1:bus1p.u.Positive-Sequence-Voltage, Magnitude
m:U1:bus1kVLine-Ground Positive-Sequence-Voltage, Magnitude
m:U1l:bus1kVLine-Line Positive-Sequence-Voltage, Magnitude
m:phiu1:bus1degPositive-Sequence-Voltage, Angle
m:irnet:bus1p.u.Current, Real Part, referred to network
m:iinet:bus1p.u.Current, Imaginary Part, referred to network
m:inet:bus1p.u.Current, Magnitude, referred to network
m:I:bus1kACurrent, Magnitude
m:phii:bus1degCurrent, Angle
m:i1r:bus1p.u.Positive-Sequence Current, Real Part
m:i1i:bus1p.u.Positive-Sequence Current, Imaginary Part
m:i1:bus1p.u.Positive-Sequence Current, Magnitude
m:I1:bus1kAPositive-Sequence Current, Magnitude
m:phii1:bus1degPositive-Sequence Current, Angle
m:P:bus1MWActive Power
m:Q:bus1MvarReactive Power
m:S:bus1MVAApparent Power
m:cosphi:bus1ยทPower Factor
m:tanphi:bus1ยทtan(phi)
m:Psum:bus1MWTotal Active Power
m:Qsum:bus1MvarTotal Reactive Power
m:Ssum:bus1MVATotal Apparent Power
m:cosphisum:bus1ยทTotal Power Factor
m:tanphisum:bus1ยทTotal tan(phi)
m:i1P:bus1p.u.Positive-Sequence Active Current
m:i1Q:bus1p.u.Positive-Sequence Reactive Current
m:I1P:bus1kAPositive-Sequence Active Current
m:I1Q:bus1kAPositive-Sequence Reactive Current
m:ur:bus1p.u.Voltage, Real Part
m:ui:bus1p.u.Voltage, Imaginary Part
m:u:bus1p.u.Voltage, Magnitude
m:ir:bus1p.u.Current, Real Part
m:ii:bus1p.u.Current, Imaginary Part
m:i:bus1p.u.Current, Magnitude
m:phiui:bus1degAngle between Voltage and Current
m:phiu1i1:bus1degAngle between Voltage and Current in positive sequence system
m:Tfct:bus1sFault Clearing Time
m:Brkload:bus1%Breaker Loading
m:Spu:bus1MVA/p.u.Apparent Power per p.u. Voltage
m:urnet:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage, Real Part, referred to network
m:uinet:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage, Imaginary Part, referred to network
m:u0:bus1p.u.Zero-Sequence-Voltage, Magnitude
m:phiu0:bus1degZero-Sequence-Voltage, Angle
m:u2:bus1p.u.Negative-Sequence-Voltage, Magnitude
m:phiu2:bus1degNegative-Sequence-Voltage, Angle
m:irnet:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, Real Part
m:iinet:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, Imaginary Part
m:inet:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, Magnitude
m:I:bus1:Aper phase :A, :B, :C, unbalanced onlykAPhase Current, Magnitude
m:phii:bus1:Aper phase :A, :B, :C, unbalanced onlydegPhase Current, Angle
m:i0r:bus1p.u.Zero-Sequence Current, Real Part
m:i0i:bus1p.u.Zero-Sequence Current, Imaginary Part
m:i0:bus1p.u.Zero-Sequence Current, Magnitude
m:I0:bus1kAZero-Sequence Current, Magnitude
m:I0x3:bus1kA3*I0
m:phii0:bus1degZero-Sequence Current, Angle
m:i2r:bus1p.u.Negative-Sequence Current, Real Part
m:i2i:bus1p.u.Negative-Sequence Current, Imaginary Part
m:i2:bus1p.u.Negative-Sequence Current, Magnitude
m:I2:bus1kANegative-Sequence Current, Magnitude
m:phii2:bus1degNegative-Sequence Current, Angle
m:P:bus1:Aper phase :A, :B, :C, unbalanced onlyMWActive Power
m:Q:bus1:Aper phase :A, :B, :C, unbalanced onlyMvarReactive Power
m:S:bus1:Aper phase :A, :B, :C, unbalanced onlyMVAApparent Power
m:cosphi:bus1:Aper phase :A, :B, :C, unbalanced onlyยทPower Factor
m:tanphi:bus1:Aper phase :A, :B, :C, unbalanced onlyยทtan(phi)
m:Pln:bus1:Aper phase :A, :B, :C, unbalanced onlyMWActive Power (Line-Neutral)
m:Qln:bus1:Aper phase :A, :B, :C, unbalanced onlyMvarReactive Power (Line-Neutral)
m:P1:bus1MWPositive Sequence Active Power
m:Q1:bus1MvarPositive Sequence Reactive Power
m:P2:bus1MWNegative Sequence Active Power
m:Q2:bus1MvarNegative Sequence Reactive Power
m:P0:bus1MWZero Sequence Active Power
m:Q0:bus1MvarZero Sequence Reactive Power
m:i2P:bus1p.u.Negative-Sequence Active Current
m:i2Q:bus1p.u.Negative-Sequence Reactive Current
m:I2P:bus1kANegative-Sequence Active Current
m:I2Q:bus1kANegative-Sequence Reactive Current
m:ur:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage, Real Part
m:ui:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage, Imaginary Part
m:u:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage, Magnitude
m:ir:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, Real Part
m:ii:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, Imaginary Part
m:i:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, Magnitude
m:phiui:bus1:Aper phase :A, :B, :C, unbalanced onlydegAngle between Voltage and Current
m:phiu0i0:bus1degAngle between Voltage and Current in zero-sequence system
m:phiu2i2:bus1degAngle between Voltage and Current in negative sequence system
m:TfctPh:bus1:Aper phase :A, :B, :C, unbalanced onlysFault Clearing Time
m:BrkloadPh:bus1:Aper phase :A, :B, :C, unbalanced only%Breaker Loading
c:sgnnMVATotal rated apparent power (ngnum*sgn)
c:cosnยทNominal-Power factor
c:uminp.u.iconfed
c:pf_recapยทPower Factor ind/cap
c:hpirad/sNominal angular frequency
c:phiuradVoltage angle
n:ur:bus1p.u.Voltage, Real Part
n:ui:bus1p.u.Voltage, Imaginary Part
n:u:bus1p.u.Voltage, Magnitude
n:upc:bus1%Voltage, Magnitude
n:du:bus1%Voltage Deviation
n:U:bus1kVLine-Ground Voltage, Magnitude
n:phiu:bus1degVoltage, Angle
n:phiurel:bus1degVoltage, Relative Angle
n:Ul:bus1kVLine-Line Voltage, Magnitude
n:u1:bus1p.u.Voltage, Magnitude
n:u1pc:bus1%Voltage, Magnitude
n:u1r:bus1p.u.Positive-Sequence Voltage, Real Part
n:u1i:bus1p.u.Positive-Sequence Voltage, Imaginary Part
n:ishc:bus1p.u.Short-Circuit Current, magnitude
n:Ishc:bus1kAShort-Circuit Current, magnitude
n:fe:bus1p.u.Electrical Frequency
n:dfehz:bus1HzDeviation of the El. Frequency
n:fehz:bus1HzElectrical Frequency
n:frnom:bus1HzNominal Frequency
n:ishcr:bus1p.u.Short-Circuit Current, real
n:ishci:bus1p.u.Short-Circuit Current, imag
n:dfedt:bus1p.u./sDerivative of El. Frequency
n:ur:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Ground Voltage, Real Part
n:ui:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Ground Voltage, Imaginary Part
n:u:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Ground Voltage, Magnitude
n:upc:bus1:Aper phase :A, :B, :C, unbalanced only%Line-Ground Voltage, Magnitude
n:du:bus1:Aper phase :A, :B, :C, unbalanced only%Voltage Deviation
n:U:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Ground Voltage, Magnitude
n:phiu:bus1:Aper phase :A, :B, :C, unbalanced onlydegLine-Ground Voltage, Angle
n:ul:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Line Voltage, Magnitude
n:ulpc:bus1:Aper phase :A, :B, :C, unbalanced only%Line-Line Voltage, Magnitude
n:Ul:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Line Voltage, Magnitude
n:phiul:bus1:Aper phase :A, :B, :C, unbalanced onlydegLine-Line Voltage, Angle
n:u0:bus1p.u.Zero-Sequence Voltage, Magnitude
n:U0:bus1kVZero-Sequence Voltage, Magnitude
n:U0x3:bus1kV3*U0
n:phiu0:bus1degZero-Sequence Voltage, Angle
n:U1:bus1kVLine-Ground Positive-Sequence Voltage, Magnitude
n:phiu1:bus1degPositive-Sequence Voltage, Angle
n:u2:bus1p.u.Negative-Sequence Voltage, Magnitude
n:U2:bus1kVLine-Ground Negative-Sequence Voltage, Magnitude
n:phiu2:bus1degNegative-Sequence Voltage, Angle
n:U1l:bus1kVLine-Line Positive-Sequence Voltage, Magnitude
n:U2l:bus1kVLine-Line Negative-Sequence Voltage, Magnitude
n:uln:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Neutral Voltage, Magnitude
n:Uln:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Neutral Voltage, Magnitude
n:phiuln:bus1:Aper phase :A, :B, :C, unbalanced onlydegLine-Neutral Voltage, Angle
n:un:bus1p.u.Neutral-Ground Voltage, Magnitude
n:Un:bus1kVNeutral-Ground Voltage, Magnitude
n:phiun:bus1degNeutral-Ground Voltage, Angle
n:upht:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Technology dependent Voltage, Magnitude
n:Upht:bus1:Aper phase :A, :B, :C, unbalanced onlykVPhase Technology dependent Voltage, Magnitude
n:um:bus1p.u.Average-Voltage, Magnitude
n:Um:bus1kVAverage-Voltage, Magnitude
n:ishc:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Short-Circuit Current, magnitude
n:Ishc:bus1:Aper phase :A, :B, :C, unbalanced onlykAShort-Circuit Current, magnitude
n:inshc:bus1p.u.Neutral Short-Circuit Current, magnitude
n:Inshc:bus1kANeutral Short-Circuit Current, magnitude
n:ishcr:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Short-Circuit Current, real
n:ishci:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Short-Circuit Current, imag
s:PextMWActive Power Input
s:QextMvarReactive Power Input
s:scaleยทScale Factor
s:f0p.u.Frequency input
s:F0HzHzFrequency input (Hz)
s:frefp.u.Reference frequency
s:id_refp.u.d-axis current reference
s:iq_refp.u.q-axis current reference
s:u1r_inp.u.Voltage input, real part
s:u1i_inp.u.Voltage input, imaginary part
s:cosrefยทcos(dq-reference angle)
s:sinrefยทsin(dq-reference angle)
s:simModelยท0 - Current source model, 1 - Voltage source model
s:xspeedp.u.Frequency
s:idp.u.Current, d-Axis
s:iqp.u.Current, q-Axis
s:i2d_refp.u.Negative sequence current, d-axis reference
s:i2q_refp.u.Negative sequence current, q-axis reference
s:u2r_inp.u.Negative sequence voltage input, real part
s:u2i_inp.u.Negative sequence voltage input, imaginary part
s:cos2refยทcos(negative sequence dq-reference angle)
s:sin2refยทsin(negative sequence dq-reference angle)
s:u0r_inp.u.Zero sequence voltage input, real part
s:u0i_inp.u.Zero sequence voltage input, imaginary part
s:phiuradVoltage-Angle

ElmPvsys emt simulation results

Read after ComInc (EMT) with GetAttribute. m: currents, voltages and powers, c: calculation parameter, n: bus result at a terminal, s: signal (state or model variable).

AttributeUnitDescription
m:u0:bus1p.u.Zero-Sequence-Voltage
m:u1r:bus1p.u.Voltage Phasor, Real Part
m:u1i:bus1p.u.Voltage Phasor, Imaginary Part
m:u1:bus1p.u.Voltage Phasor, Magnitude
m:U1:bus1kVLine-Ground Voltage Phasor, Magnitude
m:U1l:bus1kVLine-Line Voltage Phasor, Magnitude
m:phiu1:bus1degVoltage Phasor, Angle
m:inet:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current, referred to network
m:I:bus1:Aper phase :A, :B, :C, unbalanced onlykAPhase Current
m:i0:bus1p.u.Zero-Sequence Current
m:I0:bus1kAZero-Sequence Current
m:I0x3:bus1kA3*I0
m:i1r:bus1p.u.Current Phasor, Real Part
m:i1i:bus1p.u.Current Phasor, Imaginary Part
m:i1:bus1p.u.Current Phasor, Magnitude
m:I1:bus1kACurrent Phasor, Magnitude
m:phii1:bus1degCurrent Phasor, Angle
m:P:bus1:Aper phase :A, :B, :C, unbalanced onlyMWActive Power
m:Psum:bus1MWPower-Phasor, Active Power
m:Qsum:bus1MvarPower Phasor, Reactive Part
m:Ssum:bus1MVAPower Phasor, Apparent Power
m:i1P:bus1p.u.Current Phasor, Active Current
m:i1Q:bus1p.u.Current Phasor, Reactive Current
m:I1P:bus1kACurrent Phasor, Active Current
m:I1Q:bus1kACurrent Phasor, Reactive Current
m:u:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage
m:i:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Current
m:phiu1i1:bus1degAngle between Voltage and Current Phasor
m:Tfct:bus1sFault Clearing Time
m:TfctPh:bus1:Aper phase :A, :B, :C, unbalanced onlysFault Clearing Time
m:unet:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage, referred to network
m:cosphi1:bus1ยทPower-Phasor, Power-Factor
c:sgnnMVATotal rated apparent power (ngnum*sgn)
c:cosnยทNominal power factor
c:hpirad/sNominal angular frequency
c:u1_pllp.u.PLL Voltage
n:u:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Phase Voltage
n:upc:bus1:Aper phase :A, :B, :C, unbalanced only%Phase Voltage
n:U:bus1:Aper phase :A, :B, :C, unbalanced onlykVPhase Voltage
n:ul:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Line Voltage
n:ulpc:bus1:Aper phase :A, :B, :C, unbalanced only%Line-Line Voltage
n:Ul:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Line Voltage
n:u0:bus1p.u.Zero-Sequence-Voltage
n:U0:bus1kVZero-Sequence-Voltage
n:U0x3:bus1kV3*U0
n:u1:bus1p.u.Voltage Phasor, Magnitude
n:u1pc:bus1%Voltage Phasor, Magnitude
n:u1r:bus1p.u.Voltage Phasor, Real Part
n:u1i:bus1p.u.Voltage Phasor, Imaginary Part
n:U1:bus1kVVoltage Phasor, Magnitude
n:phiu1:bus1degVoltage Phasor, Angle
n:U1l:bus1kVLine-Line Voltage Phasor, Magnitude
n:uln:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Line-Neutral Voltage
n:Uln:bus1:Aper phase :A, :B, :C, unbalanced onlykVLine-Neutral Voltage
n:un:bus1p.u.Neutral-Ground Voltage
n:Un:bus1kVNeutral-Ground Voltage
n:ishc:bus1:Aper phase :A, :B, :C, unbalanced onlyp.u.Short-Circuit Current
n:Ishc:bus1:Aper phase :A, :B, :C, unbalanced onlykAShort-Circuit Current
n:inshc:bus1p.u.Neutral Short-Circuit Current, magnitude
n:Inshc:bus1kANeutral Short-Circuit Current, magnitude
n:fe:bus1p.u.Electrical Frequency
n:dfehz:bus1HzDeviation of the El. Frequency
n:fehz:bus1HzElectrical Frequency
n:frnom:bus1HzNominal Frequency
s:f0p.u.Frequency input
s:F0HzHzFrequency input (Hz)
s:frefp.u.Reference frequency
s:id_refp.u.d-axis current reference
s:iq_refp.u.q-axis current reference
s:i2d_refp.u.Negative sequence current, d-axis reference
s:i2q_refp.u.Negative sequence current, q-axis reference
s:u1r_inp.u.Voltage input, real part
s:u1i_inp.u.Voltage input, imaginary part
s:cosrefยทcos(dq-reference angle)
s:sinrefยทsin(dq-reference angle)
s:simModelยท0 - Current source model, 1 - Voltage source model
s:idp.u.Current, d-axis
s:iqp.u.Current, q-axis
s:phiuradVoltage angle
s:iin_ap.u.Current, phase A
s:iin_bp.u.Current, phase B
s:iin_cp.u.Current, phase C
s:xdp.u.State variable, current controller d-axis
s:xqp.u.State variable, current controller q-axis
s:u0_inp.u.Voltage input, zero sequence component
s:x1_plluยทx1 State Variable (Voltage PLL)
s:x2_plluradx2 State Variable (Voltage PLL)
s:xd_plluยทxd State Variable (Voltage PLL)
s:xq_plluยทxq State Variable (Voltage PLL)
s:x1_plliยทx1 State Variable (Current PLL)
s:x2_plliradx2 State Variable (Current PLL)
s:xd_plliยทxd State Variable (Current PLL)
s:xq_plliยทxq State Variable (Current PLL)

ElmPvsys dc load flow results

Read after ComLdf (DC) with GetAttribute. m: currents, voltages and powers, c: calculation parameter, n: bus result at a terminal, s: signal (state or model variable).

AttributeUnitDescription
m:P:bus1MWActive Power
m:Q:bus1MvarReactive Power
c:sgnnMVATotal rated apparent power (ngnum*sgn)
c:cosnยทNominal-Power factor
c:pMWTotal Active Power
c:PnomMWTotal Nominal Active power
c:phiiniยทInitial Angle
c:loading%Loading
c:iPowerOnยทFlag
c:PminMWLower limit of active power
c:PmaxMWUpper limit of active power
c:i_plimยทActive power limit reached
c:Kpp.u.Active Power Participation
c:KpfMW/HzFrequency Bias
c:iRefElementยทReference Element
c:NnomยทNumber of parallel units
c:zonewscaleยทWind generation zone scaling factor
c:PmismMWActive Power Mismatch
c:PlossMWLosses (total)
c:QlossMvarReactive-Losses (total)
c:SnomMVANom. Apparent Power (1 mach.)
c:cst_dispUSD/hOperating Costs
n:u:bus1p.u.Voltage, Magnitude
n:upc:bus1%Voltage, Magnitude
n:U:bus1kVLine-Ground Voltage, Magnitude
n:phiu:bus1degVoltage, Angle
n:phiurel:bus1degVoltage, Relative Angle
n:Ul:bus1kVLine-Line Voltage, Magnitude
n:u1:bus1p.u.Voltage, Magnitude
n:Pgen:bus1MWGeneration, Active Power
n:Pmot:bus1MWMotor Load, Active Power
n:Pload:bus1MWGeneral Load, Active Power
n:Pcomp:bus1MWCompensation (Losses)
n:Pnet:bus1MWExternal Networks, Active Power
n:Pflow:bus1MWPower Flow, Active Power
s:psetMWActive Power Setpoint
s:dFinHzFrequency Deviation

Read after ComMod with GetAttribute. c: calculation parameter, s: signal (state or model variable).

AttributeUnitDescription
c:sgnnMVATotal rated apparent power (ngnum*sgn)
c:cosnยทNominal-Power factor
c:uminp.u.iconfed
c:pf_recapยทPower Factor ind/cap
c:hpirad/sNominal angular frequency
c:phiuradVoltage angle
s:PextMWActive Power Input
s:QextMvarReactive Power Input
s:scaleยทScale Factor
s:f0p.u.Frequency input
s:F0HzHzFrequency input (Hz)
s:frefp.u.Reference frequency
s:id_refp.u.d-axis current reference
s:iq_refp.u.q-axis current reference
s:u1r_inp.u.Voltage input, real part
s:u1i_inp.u.Voltage input, imaginary part
s:cosrefยทcos(dq-reference angle)
s:sinrefยทsin(dq-reference angle)
s:simModelยท0 - Current source model, 1 - Voltage source model
s:xspeedp.u.Frequency
s:idp.u.Current, d-Axis
s:iqp.u.Current, q-Axis

ElmPvsys optimal power flow results

Read after ComOpf with GetAttribute. m: currents, voltages and powers, c: calculation parameter, n: bus result at a terminal.

AttributeUnitDescription
m:urnet:bus1p.u.Voltage, Real Part, referred to network
m:uinet:bus1p.u.Voltage, Imaginary Part, referred to network
m:u1r:bus1p.u.Positive-Sequence-Voltage, Real Part
m:u1i:bus1p.u.Positive-Sequence-Voltage, Imaginary Part
m:u1:bus1p.u.Positive-Sequence-Voltage, Magnitude
m:U1:bus1kVLine-Ground Positive-Sequence-Voltage, Magnitude
m:U1l:bus1kVLine-Line Positive-Sequence-Voltage, Magnitude
m:phiu1:bus1degPositive-Sequence-Voltage, Angle
m:irnet:bus1p.u.Current, Real Part, referred to network
m:iinet:bus1p.u.Current, Imaginary Part, referred to network
m:inet:bus1p.u.Current, Magnitude, referred to network
m:I:bus1kACurrent, Magnitude
m:phii:bus1degCurrent, Angle
m:i1r:bus1p.u.Positive-Sequence Current, Real Part
m:i1i:bus1p.u.Positive-Sequence Current, Imaginary Part
m:i1:bus1p.u.Positive-Sequence Current, Magnitude
m:I1:bus1kAPositive-Sequence Current, Magnitude
m:phii1:bus1degPositive-Sequence Current, Angle
m:P:bus1MWActive Power
m:Q:bus1MvarReactive Power
m:S:bus1MVAApparent Power
m:cosphi:bus1ยทPower Factor
m:tanphi:bus1ยทtan(phi)
m:Psum:bus1MWTotal Active Power
m:Qsum:bus1MvarTotal Reactive Power
m:Ssum:bus1MVATotal Apparent Power
m:cosphisum:bus1ยทTotal Power Factor
m:tanphisum:bus1ยทTotal tan(phi)
m:i1P:bus1p.u.Positive-Sequence Active Current
m:i1Q:bus1p.u.Positive-Sequence Reactive Current
m:I1P:bus1kAPositive-Sequence Active Current
m:I1Q:bus1kAPositive-Sequence Reactive Current
m:ur:bus1p.u.Voltage, Real Part
m:ui:bus1p.u.Voltage, Imaginary Part
m:u:bus1p.u.Voltage, Magnitude
m:ir:bus1p.u.Current, Real Part
m:ii:bus1p.u.Current, Imaginary Part
m:i:bus1p.u.Current, Magnitude
m:phiui:bus1degAngle between Voltage and Current
m:phiu1i1:bus1degAngle between Voltage and Current in positive sequence system
m:Tfct:bus1sFault Clearing Time
m:Brkload:bus1%Breaker Loading
m:Spu:bus1MVA/p.u.Apparent Power per p.u. Voltage
c:sgnnMVATotal rated apparent power (ngnum*sgn)
c:cosnยทNominal-Power factor
c:pMWTotal Active Power
c:qMvarTotal Reactive Power
c:PnomMWTotal Nominal Active power
c:c2ยทVoltage Coefficient (uknom/ugn)
c:uinip.u.Voltage Setpoint for PV and Slack
c:phiiniยทInitial Angle
c:phirelrefradRelative reference angle
c:loading%Loading
c:iPowerOnยทFlag
c:QminMvarLower limit of reactive power
c:QmaxMvarUpper limit of reactive power
c:QspareleadMvarQ spare lead
c:QsparelagMvarQ spare lag
c:i_qlimยทReactive power limit reached
c:i_vlimยทVoltage setpoint limit reached
c:PminMWLower limit of active power
c:PmaxMWUpper limit of active power
c:i_plimยทActive power limit reached
c:smMVAComplex Power
c:u1p.u.Internal
c:Kpp.u.Active Power Participation
c:Kqp.u.Reactive Power Participation
c:KpfMW/HzFrequency Bias
c:iRefElementยทReference Element
c:NnomยทNumber of parallel units
c:zonewscaleยทWind generation zone scaling factor
c:PmismMWActive Power Mismatch
c:nCtrlIterยทNo. of CTRL-iterations
c:PlossMWLosses (total)
c:QlossMvarReactive-Losses (total)
c:PlossldMWLosses (load)
c:QlossldMvarReactive-Losses (load)
c:PlossnldMWLosses (no load)
c:QlossnldMvarReactive-Losses (no load)
c:SnomMVANom. Apparent Power (1 mach.)
c:cst_dispUSD/hOperating Costs
c:QtargetMvarQ target value
c:QtargetDeltaMvarDeviation from Q target value
c:PtargetMWP target value
c:Pmax_ucMWMaximum Power
c:Pmin_ucMWMinimum Power
c:totRedispatchPMWhTotal redispatched energy
c:totRedispatchQMvarhTotal redispatched energy
c:totRedispatchCostsUSDTotal redispatch costs
n:ur:bus1p.u.Voltage, Real Part
n:ui:bus1p.u.Voltage, Imaginary Part
n:u:bus1p.u.Voltage, Magnitude
n:upc:bus1%Voltage, Magnitude
n:du:bus1%Voltage Deviation
n:U:bus1kVLine-Ground Voltage, Magnitude
n:phiu:bus1degVoltage, Angle
n:phiurel:bus1degVoltage, Relative Angle
n:Ul:bus1kVLine-Line Voltage, Magnitude
n:u1:bus1p.u.Voltage, Magnitude
n:u1pc:bus1%Voltage, Magnitude
n:u1r:bus1p.u.Positive-Sequence Voltage, Real Part
n:u1i:bus1p.u.Positive-Sequence Voltage, Imaginary Part
n:Pgen:bus1MWGeneration, Active Power
n:Qgen:bus1MvarGeneration, Reactive Power
n:Pmot:bus1MWMotor Load, Active Power
n:Qmot:bus1MvarMotor Load, Reactive Power
n:Pload:bus1MWGeneral Load, Active Power
n:Qload:bus1MvarGeneral Load, Reactive Power
n:Pcomp:bus1MWCompensation (Losses)
n:Qcomp:bus1MvarCompensation
n:Pnet:bus1MWExternal Networks, Active Power
n:Qnet:bus1MvarExternal Networks, Reactive Power
n:Pflow:bus1MWPower Flow, Active Power
n:Qflow:bus1MvarPower Flow, Reactive Power
n:Pout:bus1MWOutgoing Flow, Active Power
n:Qout:bus1MvarOutgoing Power, Reactive Power
n:Sout:bus1MVAOutgoing Power, Apparent Power
n:cosphiout:bus1ยทOutgoing Power, Power Factor
n:Pbalance:bus1MWActive Power Balance (=0)
n:Qbalance:bus1MvarReactive Power Balance (=0)
n:LossPdown:bus1MWLosses, downstream
n:LossQdown:bus1MvarLosses, downstream (Reactive Power)
n:LossPdownload:bus1MWLoad losses, downstream
n:LossQdownload:bus1MvarLoad losses, downstream
n:LossPdownnoload:bus1MWNo load losses, downstream
n:LossQdownnoload:bus1MvarNo load losses, downstream
n:du_feed:bus1%Difference from voltage at start of feeder

ElmPvsys basic data

b: values are worked out from the input data. Read them; they are not set.

AttributeUnitDescription
b:loc_nameยทName
b:iWindGenยทWind Generator
b:sgnnMVATotal rated apparent power (ngnum*sgn)

Related

โ† ElmIac AC Current Source ยท ElmSym Synchronous Machine โ†’