master:breaker1 parametersPSCAD Single Phase Breaker
Every parameter of the PSCAD Single Phase Breaker (master:breaker1): 16 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().
What master:breaker1 is
Single Phase Breaker, a component of PSCAD's Master Library, filed under faults and switching.
Definition
master:breaker1
PSCAD name
Single Phase Breaker
Category
Faults and switching
Parameters
16, in 5 groups; 7 carry a unit
Read from
PSCAD 5.0.0, 2026-11-07
Read and write master:breaker1 in Python
import mhi.pscad
pscad = mhi.pscad.connect() # the PSCAD that is open; launch() starts one
project = pscad.project("my_case") # a case loaded in the workspacefor comp in project.find_all("master:breaker1"): # the exact definition, namespace first
params = comp.parameters() # every parameter, as PSCAD holds itprint(str(params["CLVL"])) # Current Chopping Limit, in kA
comp = project.find_all("master:breaker1")[0]
comp.parameters(CLVL="1 [kA]") # a value that carries a unit is written with it
A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.
The Builder's runtime does the same with the unit handled for you: px_get(comp, "CLVL") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.
breaker statusWritten as CLOSE (close), OPEN (open)
Configuration
Parameter
Unit
Default
Description
CLVLReal
kA
0.0
Current Chopping LimitUsed when OPCUR==0
ENABChoice
·
NO
Use Pre-Insertion Resistance?Select Yes to No to enable/disable pre-insertion resistanceWritten as NO (No), YES (Yes)
NAMEReal
·
·
Breaker NameRange 0 to 1
OPCURChoice
·
NO
Open Possible at any Current?Select Yes to open the breaker at any current, if not breaker will not open until the current is below the chopping limitWritten as NO (No), YES (Yes)
ViewBChoice
·
HIGH_VOLTAGE
Graphics DisplayWritten as LOW_VOLTAGE (Low Voltage Display), HIGH_VOLTAGE (High Voltage Display)
Internal Output Variables
Parameter
Unit
Default
Description
IBRText
·
·
Name for Breaker Current (kA)
SBRText
·
·
Name for Breaker Status
VBRText
·
·
Name for Voltage across Breaker (kV)
Pre-Insertion Data
Parameter
Unit
Default
Description
PRERReal
ohm
0.1
Pre-Insertion ResistanceAt least 0.001
PostInsChoice
·
AT_NEXT_CURRENT_ZERO
Post-insertion RemovalSelect how the post-insertion resistance be removedWritten as AT_NEXT_CURRENT_ZERO (at next current zero), AFTER_SPECIFIED_TIME (after a specified time)
TDReal
s
0.0
Time Delay for Closing BreakerAt least 0
TDBOReal
s
0.005
Minimum Time for Post-insertion RemovalAt least 0Used when PostIns