master:Sequencer_Breaker parametersPSCAD Sequencer: Close/Open Breaker

Every parameter of the PSCAD Sequencer: Close/Open Breaker (master:Sequencer_Breaker): 4 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().

What master:Sequencer_Breaker is

Sequencer: Close/Open Breaker (Sequencer (Close/Open Breaker)), a component of PSCAD's Master Library, filed under faults and switching.

Definition
master:Sequencer_Breaker
PSCAD name
Sequencer: Close/Open Breaker
Category
Faults and switching
Parameters
4, in 1 group
Read from
PSCAD 5.0.0, 2026-11-07

Read and write master:Sequencer_Breaker in Python

import mhi.pscad

pscad = mhi.pscad.connect()              # the PSCAD that is open; launch() starts one
project = pscad.project("my_case")       # a case loaded in the workspace

for comp in project.find_all("master:Sequencer_Breaker"):   # the exact definition, namespace first
    params = comp.parameters()           # every parameter, as PSCAD holds it
    print(str(params["State"]))          # State (Updated Automatically)

comp = project.find_all("master:Sequencer_Breaker")[0]
comp.parameters(State="1")               # written as text
  • A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
  • A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
  • A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
  • find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.

The Builder's runtime does the same with the unit handled for you: px_get(comp, "State") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.

Configuration

ParameterUnitDefaultDescription
BNAMEText·BRK1Breaker Name
NameText··Name for IdentificationEnter a name for identification
OpenClosChoice·CLOSE_BREAKERClose or Open BreakerWritten as CLOSE_BREAKER (Close Breaker), OPEN_BREAKER (Open Breaker)
StateInteger·0State (Updated Automatically)Used for Active GraphicsRange -2147483648 to 2147483647

Related

← master:Sequencer_Fault Sequencer: Apply/Clear Fault · master:breaker1 Single Phase Breaker →