master:breakout parametersPSCAD 3 phase to Single line Converter
Every parameter of the PSCAD 3 phase to Single line Converter (master:breakout): 2 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().
What master:breakout is
3 phase to Single line Converter (3 Phase to SLD Electrical Wire Converter), a component of PSCAD's Master Library, filed under meters and output.
- Definition
master:breakout- PSCAD name
- 3 phase to Single line Converter
- Category
- Meters and output
- Parameters
- 2, in 1 group
- Read from
- PSCAD 5.0.0, 2026-11-07
Read and write master:breakout in Python
import mhi.pscad
pscad = mhi.pscad.connect() # the PSCAD that is open; launch() starts one
project = pscad.project("my_case") # a case loaded in the workspace
for comp in project.find_all("master:breakout"): # the exact definition, namespace first
params = comp.parameters() # every parameter, as PSCAD holds it
print(str(params["Com"])) # View
comp = project.find_all("master:breakout")[0]
comp.parameters(Com="COMPACT") # a Choice is written as its symbol
- A parameter is named exactly as in the table, letter case included:
parameters()gives every one of them in a dictionary, and a name the component does not have is refused. - A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (
str(...)) or the unit is lost. PSCAD keeps a written unit as it is given:"2500 [mohm]"stays in mohm. - A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
find_all()takes the exact definition only. A wildcard or a bare name withoutmaster:comes back empty; the Builder'spx_findwalks the pages for those.
The Builder's runtime does the same with the unit handled for you: px_get(comp, "Com") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.
Configuration
| Parameter | Unit | Default | Description |
|---|---|---|---|
ComChoice | · | EXPANDED | ViewThis choice changes the graphic and connection placement.Written as EXPANDED (Expanded), COMPACT (Compact) |
DisChoice | · | NO | Display Phase InformationSelect Yes or No to display the phasing on the component graphic (i.e. A, B and C)Written as NO (No), YES (Yes) |
Related
← master:dir_neg32 Negative Sequence Directional Element · master:modulator AM/FM/PM Function →