master:breakout parametersPSCAD 3 phase to Single line Converter

Every parameter of the PSCAD 3 phase to Single line Converter (master:breakout): 2 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().

What master:breakout is

3 phase to Single line Converter (3 Phase to SLD Electrical Wire Converter), a component of PSCAD's Master Library, filed under meters and output.

Definition
master:breakout
PSCAD name
3 phase to Single line Converter
Category
Meters and output
Parameters
2, in 1 group
Read from
PSCAD 5.0.0, 2026-11-07

Read and write master:breakout in Python

import mhi.pscad

pscad = mhi.pscad.connect()              # the PSCAD that is open; launch() starts one
project = pscad.project("my_case")       # a case loaded in the workspace

for comp in project.find_all("master:breakout"):   # the exact definition, namespace first
    params = comp.parameters()           # every parameter, as PSCAD holds it
    print(str(params["Com"]))            # View

comp = project.find_all("master:breakout")[0]
comp.parameters(Com="COMPACT")           # a Choice is written as its symbol
  • A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
  • A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
  • A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
  • find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.

The Builder's runtime does the same with the unit handled for you: px_get(comp, "Com") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.

Configuration

ParameterUnitDefaultDescription
ComChoice·EXPANDEDViewThis choice changes the graphic and connection placement.Written as EXPANDED (Expanded), COMPACT (Compact)
DisChoice·NODisplay Phase InformationSelect Yes or No to display the phasing on the component graphic (i.e. A, B and C)Written as NO (No), YES (Yes)

Related

← master:dir_neg32 Negative Sequence Directional Element · master:modulator AM/FM/PM Function →