master:Cable_Coax parametersPSCAD Coax Cable Cross-Section
Every parameter of the PSCAD Coax Cable Cross-Section (master:Cable_Coax): 64 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().
What master:Cable_Coax is
Coax Cable Cross-Section (Cable Constants Coax Cable Data), a component of PSCAD's Master Library, filed under lines, cables and towers.
- Definition
master:Cable_Coax- PSCAD name
- Coax Cable Cross-Section
- Category
- Lines, cables and towers
- Parameters
- 64, in 9 groups; 27 carry a unit
- Read from
- PSCAD 5.0.0, 2026-11-07
Read and write master:Cable_Coax in Python
import mhi.pscad
pscad = mhi.pscad.connect() # the PSCAD that is open; launch() starts one
project = pscad.project("my_case") # a case loaded in the workspace
for comp in project.find_all("master:Cable_Coax"): # the exact definition, namespace first
params = comp.parameters() # every parameter, as PSCAD holds it
print(str(params["FLT"])) # Loss Tangent is Defined at, in Hz
comp = project.find_all("master:Cable_Coax")[0]
comp.parameters(FLT="120 [Hz]") # a value that carries a unit is written with it
- A parameter is named exactly as in the table, letter case included:
parameters()gives every one of them in a dictionary, and a name the component does not have is refused. - A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (
str(...)) or the unit is lost. PSCAD keeps a written unit as it is given:"2500 [mohm]"stays in mohm. - A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
find_all()takes the exact definition only. A wildcard or a bare name withoutmaster:comes back empty; the Builder'spx_findwalks the pages for those.
The Builder's runtime does the same with the unit handled for you: px_get(comp, "FLT") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.
- Configuration25
- 1st Insulating and Semi-Conductor Layer Data8
- 2nd Insulating Layer Data5
- 3rd Insulating Layer Data5
- 4th Insulating Layer Data5
- 2nd Conducting Layer Data4
- Core Conductor Data4
- 3rd Conducting Layer Data4
- 1st Conducting Layer Data4
Configuration
| Parameter | Unit | Default | Description |
|---|---|---|---|
CABNUMChoice | · | 1 | Cable NumberEnter a number for this cable. This number must be between 1 and 12, and is used by the program to determine overall conductor numbering.Written as 1 = 1, 2 = 2, 3 = 3, 4 = 4, 5 = 5, 6 = 6, 7 = 7, 8 = 8, 9 = 9, 10 = 10, 11 = 11, 12 = 12 |
CBC1Choice | · | EXCLUDED | Conducting Core isWritten as EXCLUDED (Excluded), INCLUDED (Included) |
CBC2Choice | · | INCLUDED | 1st Conducting Layer isWritten as INCLUDED (Included), EXCLUDED (Excluded) |
CBC3Choice | · | EXCLUDED | 2nd Conducting Layer isWritten as EXCLUDED (Excluded), INCLUDED (Included) |
CBC4Choice | · | EXCLUDED | 3rd conducting Layer isWritten as EXCLUDED (Excluded), INCLUDED (Included) |
CONNAM1Text | · | Conductor | Core ConductorLabel for conducting coreRange 0 to 0 |
CONNAM2Text | · | Sheath | 1st Conducting LayerLabel for 1st conducting layer (normally sheath)Range 0 to 0 |
CONNAM3Text | · | Armour | 2nd Conducting LayerLabel for 1st conducting layer (normally armour)Range 0 to 0 |
CONNAM4Text | · | Outer Conductor | 3rd Conducting LayerLabel for 1st conducting layer (normally outer conductor)Range 0 to 0 |
CROSSBONDChoice | · | DISABLED | Ideal Cross-bonding isSelect Enabled or DisabledWritten as DISABLED (Disabled), ENABLED (Enabled) |
FLTReal | Hz | 60.0 | Loss Tangent is Defined atEnter the frequency at which loss tangents are defined [Hz].Range 1e-6 to 1000 |
GROUPNOChoice | · | 1 | Cross-bonding GroupEnter the group number to which this cable belongs.Written as 1 = 1, 2 = 2, 3 = 3, 4 = 4 |
LCChoice | · | NONE | Conductors to EliminateChoose which conducting layers to eliminate (if any).Written as NONE (None), OUTERMOST_ONLY (Outermost only), ALL_CONCENTRIC (All concentric), SPECIFY (Specify) |
LLChoice | · | C1_I1_C2_I2_C3_I3 | Layer ConfigurationSelect the configuration of the cable layers. C and I represent conducting and insulating layer respectively.Written as C1, C1_I1 (C1 | I1), C1_I1_C2 (C1 | I1 | C2), C1_I1_C2_I2 (C1 | I1 | C2 | I2), C1_I1_C2_I2_C3 (C1 | I1 | C2 | I2 | C3), C1_I1_C2_I2_C3_I3 (C1 | I1 | C2 | I2 | C3 | I3), C1_I1_C2_I2_C3_I3_C4 (C1 | I1 | C2 | I2 | C3 | I3 | C4), C1_I1_C2_I2_C3_I3_C4_I4 (C1 | I1 | C2 | I2 | C3 | I3 | C4 | I4) |
NameText | · | · | Name for IdentificationEnter a name for identificationRange 0 to 0 |
OHCChoice | · | UNDERGROUND | Placement in Relation to Ground PlaneChoose whether this cable is placed above or below the ground plane.Written as UNDERGROUND (Underground), AERIAL (Aerial) |
RorTChoice | · | RADIAL_FROM_CENTRE | Layer Thickness is Specified asSelect the manner in which the layer thicknesses are specified. If radial from centre is selected, enter the distance from the centre-point to the outer radius of the layer.Written as RADIAL_FROM_CENTRE (Radial from centre), ACTUAL_THICKNESS (Actual thickness) |
SHRadChoice | · | SHOW | Detailed Graphic LabelsSelect whether or not to show detailed graphic labelsWritten as HIDE (Hide), SHOW (Show) |
ShuntAReal | mho/m | 1.0e-11 | Aerial Shunt ConductanceEnter a shunt conductance value to groundRange 1E-38 to 1 |
XReal | m | 0.0 | Horizontal Translation from CentreEnter the translation of the cable centre-point along the horizontal (x) axis [m]. This value is relative to a local x=0 point, which is derived given the position of all cables in this segment.Range -1E+38 to 1E+38 |
YReal | m | 1.0 | Depth Below Ground SurfaceEnter the depth of the cable centre-point below the earth surface [m].Range 1E-38 to 1E+38 |
Y2Real | m | 2.0 | Height Above Ground SurfaceEnter the height of the cable centre-point above the earth surface [m].Range 0 to 1000 |
elim1Choice | · | RETAIN | 1st Concentric ConductorSpecify whether or not to eliminate this layer.Written as RETAIN (Retain), ELIMINATE (Eliminate) |
elim2Choice | · | RETAIN | 2nd Concentric ConductorSpecify whether or not to eliminate this layer.Written as RETAIN (Retain), ELIMINATE (Eliminate) |
elim3Choice | · | RETAIN | 3rd Concentric ConductorSpecify whether or not to eliminate this layer.Written as RETAIN (Retain), ELIMINATE (Eliminate) |
1st Insulating and Semi-Conductor Layer Data
| Parameter | Unit | Default | Description |
|---|---|---|---|
EPS1Real | · | 4.1 | Relative PermittivityEnter the relative permittivity of this insulator.Range 1E-38 to 100 |
LT1Real | · | 0.0001 | Loss TangentEnter the loss tangent of this insulator.Range 0.0 to 10 |
PERM1Real | · | 1.0 | Relative PermeabilityEnter the relative permeability of this insulator.Range 1E-38 to 500 |
R3Real | m | 0.0395 | Outer RadiusEnter the outer radius of this insulator [m].Range 1E-38 to 1E+38 |
SL1Real | m | 0.001 | Inner Semi-conductor Layer ThicknessEnter the thickness of the inner semi-conducting layer (between insulator and core conductor) [m].Range 1E-38 to 1E+38 |
SL2Real | m | 0.001 | Outer Semi-conductor Layer ThicknessEnter the thickness of the outer semi-conducting layer (between insulator and 1st conducting layer) [m].Range 1E-38 to 1E+38 |
SemiCLChoice | · | ABSENT | Semi-conducting LayersWritten as ABSENT (Absent), PRESENT (Present) |
T3Real | m | 0.0175 | ThicknessEnter the thickness of this insulator [m].Range 1E-38 to 1E+38 |
2nd Insulating Layer Data
| Parameter | Unit | Default | Description |
|---|---|---|---|
EPS2Real | · | 2.3 | Relative PermittivityEnter the relative permittivity of this insulator.Range 1E-38 to 100 |
LT2Real | · | 0.0001 | Loss TangentEnter the loss tangent of this insulator.Range 0.0 to 10 |
PERM2Real | · | 1.0 | Relative PermeabilityEnter the relative permeability of this insulator.Range 1E-38 to 500 |
R5Real | m | 0.0475 | Outer RadiusEnter the outer radius of this insulator [m].Range 1E-38 to 1E+38 |
T5Real | m | 0.0035 | ThicknessEnter the thickness of this insulator [m].Range 1E-38 to 1E+38 |
3rd Insulating Layer Data
| Parameter | Unit | Default | Description |
|---|---|---|---|
EPS3Real | · | 1.0 | Relative PermittivityEnter the relative permittivity of this insulator.Range 1E-38 to 100 |
LT3Real | · | 0.0001 | Loss TangentEnter the loss tangent of this insulator.Range 0.0 to 10 |
PERM3Real | · | 1.0 | Relative PermeabilityEnter the relative permeability of this insulator.Range 1E-38 to 500 |
R7Real | m | 0.0635 | Outer RadiusEnter the outer radius of this insulator [m].Range 1E-38 to 1E+38 |
T7Real | m | 0.0052 | ThicknessEnter the thickness of this insulator [m].Range 1E-38 to 1E+38 |
4th Insulating Layer Data
| Parameter | Unit | Default | Description |
|---|---|---|---|
EPS4Real | · | 1.0 | Relative PermittivityEnter the relative permittivity of this insulator.Range 1E-38 to 100 |
LT4Real | · | 0.0001 | Loss TangentEnter the loss tangent of this insulator.Range 0.0 to 10 |
PERM4Real | · | 1.0 | Relative PermeabilityEnter the relative permeability of this insulator.Range 1E-38 to 500 |
R9Real | m | 0.08 | Outer RadiusEnter the outer radius of this insulator [m].Range 1E-38 to 1E+38 |
T9Real | m | 0.01 | ThicknessEnter the thickness of this insulator [m].Range 1E-38 to 1E+38 |
2nd Conducting Layer Data
| Parameter | Unit | Default | Description |
|---|---|---|---|
PERMAReal | · | 400.0 | Relative PermeabilityEnter the relative permeability of this conductor.Range 1E-38 to 500 |
R6Real | m | 0.0583 | Outer RadiusEnter the outer radius of this conducting layer [m].Range 1E-38 to 10 |
RHOAReal | ohm*m | 1.8e-7 | ResistivityEnter the resistivity of this conductor [ohm*m].Range 1E-38 to 100 |
T6Real | m | 0.0108 | ThicknessEnter the thickness of this conducting layer [m].Range 1E-38 to 10 |
Core Conductor Data
| Parameter | Unit | Default | Description |
|---|---|---|---|
PERMCReal | · | 1.0 | Relative PermeabilityEnter the relative permeability of this conductor.Range 1E-38 to 500 |
R1Real | m | 0.0 | Inner Radius (Enter 0.0 for a Solid Core):Enter the inner radius of the centre or core conductor [m]. If this conductor is solid (i.e. not hollow), then enter 0.0.Range 0 to 1E+38 |
R2Real | m | 0.022 | Outer RadiusEnter the outer radius of the centre or core conductor [m].Range 1E-38 to 1E+38 |
RHOCReal | ohm*m | 1.68e-8 | ResistivityEnter the resistivity of this conductor [ohm*m].Range 1E-38 to 100 |
3rd Conducting Layer Data
| Parameter | Unit | Default | Description |
|---|---|---|---|
PERMOReal | · | 400.0 | Relative PermeabilityEnter the relative permeability of this conductor.Range 1E-38 to 500 |
R8Real | m | 0.07 | Outer RadiusEnter the outer radius of this conducting layer [m].Range 1E-38 to 10 |
RHOOReal | ohm*m | 1.8e-7 | ResistivityEnter the resistivity of this conductor [ohm*m].Range 1E-38 to 100 |
T8Real | m | 0.0065 | ThicknessEnter the thickness of this conducting layer [m].Range 1E-38 to 10 |
1st Conducting Layer Data
| Parameter | Unit | Default | Description |
|---|---|---|---|
PERMSReal | · | 1.0 | Relative PermeabilityEnter the relative permeability of this conductor.Range 1E-38 to 500 |
R4Real | m | 0.044 | Outer RadiusEnter the outer radius of this conducting layer [m].Range 1E-38 to 1E+38 |
RHOSReal | ohm*m | 2.2e-7 | ResistivityEnter the resistivity of this conductor [ohm*m].Range 1E-38 to 100 |
T4Real | m | 0.0045 | ThicknessEnter the thickness of this conducting layer [m].Range 1E-38 to 1E+38 |
Related
← master:cable_interface Cable Interface · master:newpi Coupled PI Section →