master:cable_interface parametersPSCAD Cable Interface

Every parameter of the PSCAD Cable Interface (master:cable_interface): 24 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().

What master:cable_interface is

Cable Interface (Cable Interface (1 of 2)), a component of PSCAD's Master Library, filed under lines, cables and towers.

Definition
master:cable_interface
PSCAD name
Cable Interface
Category
Lines, cables and towers
Parameters
24, in 1 group; 3 carry a unit
Read from
PSCAD 5.0.0, 2026-11-07

Read and write master:cable_interface in Python

import mhi.pscad

pscad = mhi.pscad.connect()              # the PSCAD that is open; launch() starts one
project = pscad.project("my_case")       # a case loaded in the workspace

for comp in project.find_all("master:cable_interface"):   # the exact definition, namespace first
    params = comp.parameters()           # every parameter, as PSCAD holds it
    print(str(params["ResA"]))           # Armour Grounding Resistance, in ohm

comp = project.find_all("master:cable_interface")[0]
comp.parameters(ResA="0.002 [ohm]")      # a value that carries a unit is written with it
  • A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
  • A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
  • A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
  • find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.

The Builder's runtime does the same with the unit handled for you: px_get(comp, "ResA") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.

Configuration

ParameterUnitDefaultDescription
C10TChoice·CONDUCTORCoaxial Cable 10Configure the external electrical connections for this cable.Written as CONDUCTOR (conductor), CONDUCTOR_SHEATH (conductor/sheath), CONDUCTOR_SHEATH_ARMOUR (conductor/sheath/armour), CONDUCTOR_SHEATH_ARMOUR_OUTER_CONDUCTOR (conductor/sheath/armour/outer conductor)Used when NCAB>=10
C11TChoice·CONDUCTORCoaxial Cable 11Configure the external electrical connections for this cable.Written as CONDUCTOR (conductor), CONDUCTOR_SHEATH (conductor/sheath), CONDUCTOR_SHEATH_ARMOUR (conductor/sheath/armour), CONDUCTOR_SHEATH_ARMOUR_OUTER_CONDUCTOR (conductor/sheath/armour/outer conductor)Used when NCAB>=11
C12TChoice·CONDUCTORCoaxial Cable 12Configure the external electrical connections for this cable.Written as CONDUCTOR (conductor), CONDUCTOR_SHEATH (conductor/sheath), CONDUCTOR_SHEATH_ARMOUR (conductor/sheath/armour), CONDUCTOR_SHEATH_ARMOUR_OUTER_CONDUCTOR (conductor/sheath/armour/outer conductor)Used when NCAB>=12
C1TChoice·CONDUCTORCoaxial Cable 1Configure the external electrical connections for this cable.Written as CONDUCTOR (conductor), CONDUCTOR_SHEATH (conductor/sheath), CONDUCTOR_SHEATH_ARMOUR (conductor/sheath/armour), CONDUCTOR_SHEATH_ARMOUR_OUTER_CONDUCTOR (conductor/sheath/armour/outer conductor)
C2TChoice·CONDUCTORCoaxial Cable 2Configure the external electrical connections for this cable.Written as CONDUCTOR (conductor), CONDUCTOR_SHEATH (conductor/sheath), CONDUCTOR_SHEATH_ARMOUR (conductor/sheath/armour), CONDUCTOR_SHEATH_ARMOUR_OUTER_CONDUCTOR (conductor/sheath/armour/outer conductor)Used when NCAB>=2
C3TChoice·CONDUCTORCoaxial Cable 3Configure the external electrical connections for this cable.Written as CONDUCTOR (conductor), CONDUCTOR_SHEATH (conductor/sheath), CONDUCTOR_SHEATH_ARMOUR (conductor/sheath/armour), CONDUCTOR_SHEATH_ARMOUR_OUTER_CONDUCTOR (conductor/sheath/armour/outer conductor)Used when NCAB>=3
C4TChoice·CONDUCTORCoaxial Cable 4Configure the external electrical connections for this cable.Written as CONDUCTOR (conductor), CONDUCTOR_SHEATH (conductor/sheath), CONDUCTOR_SHEATH_ARMOUR (conductor/sheath/armour), CONDUCTOR_SHEATH_ARMOUR_OUTER_CONDUCTOR (conductor/sheath/armour/outer conductor)Used when NCAB>=4
C5TChoice·CONDUCTORCoaxial Cable 5Configure the external electrical connections for this cable.Written as CONDUCTOR (conductor), CONDUCTOR_SHEATH (conductor/sheath), CONDUCTOR_SHEATH_ARMOUR (conductor/sheath/armour), CONDUCTOR_SHEATH_ARMOUR_OUTER_CONDUCTOR (conductor/sheath/armour/outer conductor)Used when NCAB>=5
C6TChoice·CONDUCTORCoaxial Cable 6Configure the external electrical connections for this cable.Written as CONDUCTOR (conductor), CONDUCTOR_SHEATH (conductor/sheath), CONDUCTOR_SHEATH_ARMOUR (conductor/sheath/armour), CONDUCTOR_SHEATH_ARMOUR_OUTER_CONDUCTOR (conductor/sheath/armour/outer conductor)Used when NCAB>=6
C7TChoice·CONDUCTORCoaxial Cable 7Configure the external electrical connections for this cable.Written as CONDUCTOR (conductor), CONDUCTOR_SHEATH (conductor/sheath), CONDUCTOR_SHEATH_ARMOUR (conductor/sheath/armour), CONDUCTOR_SHEATH_ARMOUR_OUTER_CONDUCTOR (conductor/sheath/armour/outer conductor)Used when NCAB>=7
C8TChoice·CONDUCTORCoaxial Cable 8Configure the external electrical connections for this cable.Written as CONDUCTOR (conductor), CONDUCTOR_SHEATH (conductor/sheath), CONDUCTOR_SHEATH_ARMOUR (conductor/sheath/armour), CONDUCTOR_SHEATH_ARMOUR_OUTER_CONDUCTOR (conductor/sheath/armour/outer conductor)Used when NCAB>=8
C9TChoice·CONDUCTORCoaxial Cable 9Configure the external electrical connections for this cable.Written as CONDUCTOR (conductor), CONDUCTOR_SHEATH (conductor/sheath), CONDUCTOR_SHEATH_ARMOUR (conductor/sheath/armour), CONDUCTOR_SHEATH_ARMOUR_OUTER_CONDUCTOR (conductor/sheath/armour/outer conductor)Used when NCAB>=9
GroundAChoice·YESGround Armours With a ResistanceConfigure grounding of armours (if applicable) internally or make it available as an external connectionWritten as NO (No), YES (Yes)
GroundOCChoice·YESGround Outer Conductors With a ResistanceConfigure grounding of outer conductors (if applicable) internally or make it available as an external connectionWritten as NO (No), YES (Yes)
GroundSChoice·YESGround Sheaths With a ResistanceConfigure grounding of sheaths (if applicable) internally or make it available as an external connectionWritten as NO (No), YES (Yes)
NCABChoice·1Number of Coaxial CablesEnter the total number of coaxial cables involved.Written as 1 = 1, 2 = 2, 3 = 3, 4 = 4, 5 = 5, 6 = 6, 7 = 7, 8 = 8, 9 = 9, 10 = 10, 11 = 11, 12 = 12
NameText·CableCable NameEnter a name that exactly matches the associated cable configuration component (wire).
ResARealohm0.001Armour Grounding ResistanceEnter the resistance to be used for grounding the armours (if applicable)At least 1E-308Used when GroundA==1
ResOCRealohm0.001Outer Conductor Grounding ResistanceEnter the resistance to be used for grounding the outer conductors (if applicable)At least 1E-308Used when GroundOC==1
ResSRealohm0.001Sheath Grounding ResistanceEnter the resistance to be used for grounding the sheaths (if applicable)At least 1E-308Used when GroundS==1
dim_rInteger·0Receiving Signal DimensionEnter the dimension of optional non-electrical signal to be received from the other end of the cableRange 0 to 32
dim_sInteger·0Sending Signal DimensionEnter the dimension of optional non-electrical signal to be transferred to the other end of the cableRange 0 to 32
pipeChoice·NOT_PRESENTEncompassing Pipe Conductor isConfigure the encompassing pipe conductor (if present and insulated from ground)Written as NOT_PRESENT (not present), INSULATED_FROM_GROUND (present (insulated from ground))
send_recvChoice·AUTOMATICSegment End SpecificationSpecify which end of the transmission segment this is: Sending or receiving. It is only necessary to specify if the associated segment is part of a mutually coupled group of segments. Otherwise, you can leave this option as automatic. Specifying endpoints is necessary in order to ensure proper node/subsystem mapping and accurate runtime results.Written as AUTOMATIC (automatic), SENDING (sending), RECEIVING (receiving)

Related

← master:Line_Berg_Options Bergeron Model · master:Cable_Coax Coax Cable Cross-Section →