master:Dload parametersPSCAD Delta connected configurable load
Every parameter of the PSCAD Delta connected configurable load (master:Dload): 13 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().
What master:Dload is
Delta connected configurable load (Individually configutable Delta connected load), a component of PSCAD's Master Library, filed under passive branches, loads and filters.
- Definition
master:Dload- PSCAD name
- Delta connected configurable load
- Category
- Passive branches, loads and filters
- Parameters
- 13, in 1 group; 9 carry a unit
- Read from
- PSCAD 5.0.0, 2026-11-07
Read and write master:Dload in Python
import mhi.pscad
pscad = mhi.pscad.connect() # the PSCAD that is open; launch() starts one
project = pscad.project("my_case") # a case loaded in the workspace
for comp in project.find_all("master:Dload"): # the exact definition, namespace first
params = comp.parameters() # every parameter, as PSCAD holds it
print(str(params["Cab"])) # Capacitance, in uF
comp = project.find_all("master:Dload")[0]
comp.parameters(Cab="2 [uF]") # a value that carries a unit is written with it
- A parameter is named exactly as in the table, letter case included:
parameters()gives every one of them in a dictionary, and a name the component does not have is refused. - A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (
str(...)) or the unit is lost. PSCAD keeps a written unit as it is given:"2500 [mohm]"stays in mohm. - A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
find_all()takes the exact definition only. A wildcard or a bare name withoutmaster:comes back empty; the Builder'spx_findwalks the pages for those.
The Builder's runtime does the same with the unit handled for you: px_get(comp, "Cab") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.
Configuration
| Parameter | Unit | Default | Description |
|---|---|---|---|
ABChoice | · | RLC | Phase A to Phase B BranchSelect Phase A to Phase B branch typeWritten as R, L, C, RL, RC, LC, RLC, OPEN (Open) |
BCChoice | · | RLC | Phase B to Phase C BranchSelect Phase B to Phase C branch typeWritten as R, L, C, RL, RC, LC, RLC, OPEN (Open) |
CAChoice | · | RLC | Phase C to Phase A BranchSelect Phase C to Phase A branch typeWritten as R, L, C, RL, RC, LC, RLC, OPEN (Open) |
CabReal | uF | 1 | Capacitanceesistance of Phase A to NeutralAt least 1E-308Used when (AB==3) || (AB==5) || (AB==6) || (AB==7) |
CbcReal | uF | 1 | Capacitanceesistance of Phase B to NeutralAt least 1E-308Used when (BC==3) || (BC==5) || (BC==6) || (BC==7) |
CcaReal | uF | 1 | CapacitanceCapacitance of Phase C to NeutralAt least 1E-308Used when (CA==3) || (CA==5) || (CA==6) || (CA==7) |
LabReal | H | 0.1 | InductanceInductance of Phase A to NeutralAt least 1E-308Used when (AB==2) || (AB==4) || (AB==6) || (AB==7) |
LbcReal | H | 0.1 | InductanceInductance of Phase B to NeutralAt least 1E-308Used when (BC==2) || (BC==4) || (BC==6) || (BC==7) |
LcaReal | H | 0.1 | InductanceInductance of Phase C to NeutralAt least 1E-308Used when (CA==2) || (CA==4) || (CA==6) || (CA==7) |
NameText | · | · | NameThe name of the componentRange 0 to 0 |
RabReal | ohm | 1 | ResistanceResistance of Phase A to NeutralAt least 1E-308Used when (AB==1) || (AB==4) || (AB==5) || (AB==7) |
RbcReal | ohm | 1 | ResistanceResistance of Phase B to NeutralAt least 1E-308Used when (BC==1) || (BC==4) || (BC==5) || (BC==7) |
RcaReal | ohm | 1 | ResistanceResistance of Phase C to NeutralAt least 1E-308Used when (CA==1) || (CA==4) || (CA==5) || (CA==7) |
Related