master:fp_int parametersPSCAD Interpolated Firing Pulses
Every parameter of the PSCAD Interpolated Firing Pulses (master:fp_int): 10 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().
What master:fp_int is
Interpolated Firing Pulses, a component of PSCAD's Master Library, filed under control blocks.
- Definition
master:fp_int- PSCAD name
- Interpolated Firing Pulses
- Category
- Control blocks
- Parameters
- 10, in 4 groups; 1 carry a unit
- Read from
- PSCAD 5.0.0, 2026-11-07
Read and write master:fp_int in Python
import mhi.pscad
pscad = mhi.pscad.connect() # the PSCAD that is open; launch() starts one
project = pscad.project("my_case") # a case loaded in the workspace
for comp in project.find_all("master:fp_int"): # the exact definition, namespace first
params = comp.parameters() # every parameter, as PSCAD holds it
print(str(params["PTime"])) # Pulse Duration:, in s
comp = project.find_all("master:fp_int")[0]
comp.parameters(PTime="0.01 [s]") # a value that carries a unit is written with it
- A parameter is named exactly as in the table, letter case included:
parameters()gives every one of them in a dictionary, and a name the component does not have is refused. - A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (
str(...)) or the unit is lost. PSCAD keeps a written unit as it is given:"2500 [mohm]"stays in mohm. - A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
find_all()takes the exact definition only. A wildcard or a bare name withoutmaster:comes back empty; the Builder'spx_findwalks the pages for those.
The Builder's runtime does the same with the unit handled for you: px_get(comp, "PTime") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.
Block Data
| Parameter | Unit | Default | Description |
|---|---|---|---|
BTypeChoice | · | GROUP | Block/Deblock Input:Choose Group or IndividualWritten as GROUP (Group), INDIVIDUAL (Individual)Used when (Blck==1&&PNum==1) |
Configuration
| Parameter | Unit | Default | Description |
|---|---|---|---|
BlckChoice | · | NO | Add Block/Deblock Signal?Choose Yes or NoWritten as NO (No), YES (Yes) |
NameText | · | · | Name for IdentificationEnter a name for identification |
PFormatChoice | · | INDIVIDUAL_DEVICES | Format of Pulse,Time Output:Individual devices (6 outputs of dimension 2) or 6 Pulse Valve group (2 outputs of dimension 6)Written as INDIVIDUAL_DEVICES (To Individual Devices), SIX_PULSE_THYRISTOR_GROUP (To Six Pulse Thyristor Group)Used when (Type==0)&&(PNum==1) |
PNumChoice | · | ONE | Number of PulsesChoose 1 or 6Written as ONE (One), SIX (Six) |
TypeChoice | · | THYRISTOR | Thyristor or GTO?Select from Thyristor or GTOWritten as THYRISTOR (Thyristor), GTO |
detectChoice | · | DISARMED | Band Limit Proximity CorrectionChoose Armed or DisarmedWritten as DISARMED (Disarmed), MUST_INDICATE_H_INPUT_BAND_LIMITS (Armed (must indicate H input band limits)) |
Pulse Data
| Parameter | Unit | Default | Description |
|---|---|---|---|
PTimeReal | s | 0.005 | Pulse Duration:Range 1E-12 to 1000000000000Used when (Type==0) |
Band Limit Proximity Data
| Parameter | Unit | Default | Description |
|---|---|---|---|
maxReal | · | 360.0 | H Input Maximum LimitRange -1000000000000 to 1000000000000 |
minReal | · | 0.0 | H Input Minimum LimitRange -1000000000000 to 1000000000000 |
Related
← master:Zintegral Integrator · master:leadlag Lead-Lag Pole →