master:Zintegral parametersPSCAD Integrator
Every parameter of the PSCAD Integrator (master:Zintegral): 10 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().
What master:Zintegral is
Integrator (Z domain integrator), a component of PSCAD's Master Library, filed under control blocks.
- Definition
master:Zintegral- PSCAD name
- Integrator
- Category
- Control blocks
- Parameters
- 10, in 1 group; 1 carry a unit
- Read from
- PSCAD 5.0.0, 2026-11-07
Read and write master:Zintegral in Python
import mhi.pscad
pscad = mhi.pscad.connect() # the PSCAD that is open; launch() starts one
project = pscad.project("my_case") # a case loaded in the workspace
for comp in project.find_all("master:Zintegral"): # the exact definition, namespace first
params = comp.parameters() # every parameter, as PSCAD holds it
print(str(params["T"])) # Time Constant, in s
comp = project.find_all("master:Zintegral")[0]
comp.parameters(T="0.002 [s]") # a value that carries a unit is written with it
- A parameter is named exactly as in the table, letter case included:
parameters()gives every one of them in a dictionary, and a name the component does not have is refused. - A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (
str(...)) or the unit is lost. PSCAD keeps a written unit as it is given:"2500 [mohm]"stays in mohm. - A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
find_all()takes the exact definition only. A wildcard or a bare name withoutmaster:comes back empty; the Builder'spx_findwalks the pages for those.
The Builder's runtime does the same with the unit handled for you: px_get(comp, "T") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.
Configuration
| Parameter | Unit | Default | Description |
|---|---|---|---|
DimInteger | · | 1 | Dimensiondimension of input/output signalsRange 1 to 2147483647 |
INTRChoice | · | NO | Is Input Already Sampled?Select Yes if the input is already sampled with the same execution frequency, Select No if sampling is needed.Written as YES (Yes), NO (No) |
LimitChoice | · | NO | Limit Output?Select Yes to enable non windup limitsWritten as NO (No), YES (Yes) |
MethodChoice | · | TRAPEZOIDAL | Integration MethodSelect the integration method: Forward Euler, Backward Euler or TrapezoidalWritten as FORWARD_EULER (Forward Euler), BACKWARD_EULER (Backward Euler), TRAPEZOIDAL (Trapezoidal) |
NameText | · | · | Name for identificationEnter a name for identification |
ResetChoice | · | NEVER | Resettable?Select when to enable resetWritten as NEVER (Never), ANYTIME (Anytime), TIMEZERO (Timezero) |
TReal | s | 0.001 | Time ConstantAt least 1E-20 |
YHiReal | · | 100.0 | Maximum LimitUsed when Limit==1 |
YLoReal | · | -100.0 | Minimum LimitUsed when Limit==1 |
YOReal | · | 0.0 | Reset ValueOutput when the reset is enabledUsed when Reset!=0 |
Related
← master:integral Integrator · master:fp_int Interpolated Firing Pulses →