master:Line_Out_Disp parametersPSCAD LCP Additional Options

Every parameter of the PSCAD LCP Additional Options (master:Line_Out_Disp): 6 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().

What master:Line_Out_Disp is

LCP Additional Options, a component of PSCAD's Master Library, filed under lines, cables and towers.

Definition
master:Line_Out_Disp
PSCAD name
LCP Additional Options
Category
Lines, cables and towers
Parameters
6, in 1 group; 4 carry a unit
Read from
PSCAD 5.0.0, 2026-11-07

Read and write master:Line_Out_Disp in Python

import mhi.pscad

pscad = mhi.pscad.connect()              # the PSCAD that is open; launch() starts one
project = pscad.project("my_case")       # a case loaded in the workspace

for comp in project.find_all("master:Line_Out_Disp"):   # the exact definition, namespace first
    params = comp.parameters()           # every parameter, as PSCAD holds it
    print(str(params["DataF"]))          # Frequency for Calculation (must be greater than 0.0), in Hz

comp = project.find_all("master:Line_Out_Disp")[0]
comp.parameters(DataF="120 [Hz]")        # a value that carries a unit is written with it
  • A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
  • A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
  • A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
  • find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.

The Builder's runtime does the same with the unit handled for you: px_get(comp, "DataF") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.

Configuration

ParameterUnitDefaultDescription
DataFRealHz60.0Frequency for Calculation (must be greater than 0.0)Enter the steady-state frequency for calculation of the output file data [Hz].Range 1e-038 to 1e+038
MVAbaseRealMVA100.0Rated System MVAEnter the system base MVA for calculation of per-unit values in the Load Flow RXB Formatted Data section of the output file [MVA].Range 1e-038 to 1e+038
RipRealohm1.0E5Include Shunt Resistance when calculated values are less than:If calculated shunt resistances are greater than this number, they will not be included when the equivalent pi-section component is built [ohm].Range 1e-038 to 1e+038
VbaseRealkV230.0Rated System Voltage (L-L,RMS)Enter the system base voltage for calculation of per-unit values in the Load Flow RXB Formatted Data section of the output file [kV].Range 1e-038 to 1e+038
Zero_TolReal·1e-19Default Zero Tolerance for DisplayEnter a value, below which all display data will be set to exactly 0.0. This can help in making the output data file easier to read.Range 1e-083 to 1e+083
picompChoice·DISABLEDCreation of Equivalent Pi-section Definition isSelect whether to enable or disable equivalent pi-section creation. If enabled, an equivalent pi-section component definition (*.psdx) file, representing this right-of-way, will be created and placed in the project temporary folder each time this segment is solved.Written as DISABLED (Disabled), ENABLED (Enabled)