master:mmc_FiringFullBridge parametersPSCAD Firing Pulse Generator for MMC Full Cell

Every parameter of the PSCAD Firing Pulse Generator for MMC Full Cell (master:mmc_FiringFullBridge): 4 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().

What master:mmc_FiringFullBridge is

Firing Pulse Generator for MMC Full Cell (Firing Block for MMC Half Cell), a component of PSCAD's Master Library, filed under other components.

Definition
master:mmc_FiringFullBridge
PSCAD name
Firing Pulse Generator for MMC Full Cell
Category
Other components
Parameters
4, in 1 group
Read from
PSCAD 5.0.0, 2026-11-07

Read and write master:mmc_FiringFullBridge in Python

import mhi.pscad

pscad = mhi.pscad.connect()              # the PSCAD that is open; launch() starts one
project = pscad.project("my_case")       # a case loaded in the workspace

for comp in project.find_all("master:mmc_FiringFullBridge"):   # the exact definition, namespace first
    params = comp.parameters()           # every parameter, as PSCAD holds it
    print(str(params["DimFb"]))          # Number of Cells per Arm

comp = project.find_all("master:mmc_FiringFullBridge")[0]
comp.parameters(DimFb="20")              # written as text
  • A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
  • A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
  • A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
  • find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.

The Builder's runtime does the same with the unit handled for you: px_get(comp, "DimFb") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.

Configuration

ParameterUnitDefaultDescription
DimFbInteger·10Number of Cells per ArmRange 2 to 10000
FrChangeChoice·YESChange Cells Fired when Number of Cells Change?Written as YES (Yes), NO (No)
FrClkInteger·1Firing Clock SignalEnter 1 if you want to fire at every time stepRange 0 to 1Used when FrChange==0
NameText··NameName for easy identificationRange 0 to 0

Related

← master:xnode External Electrical Node · master:mmc_FiringHalfBridge Firing Pulse Generator for MMC Half Cell →