master:mmc_FiringHalfBridge parametersPSCAD Firing Pulse Generator for MMC Half Cell
Every parameter of the PSCAD Firing Pulse Generator for MMC Half Cell (master:mmc_FiringHalfBridge): 3 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().
What master:mmc_FiringHalfBridge is
Firing Pulse Generator for MMC Half Cell (Firing Block for MMC Half Cell), a component of PSCAD's Master Library, filed under other components.
- Definition
master:mmc_FiringHalfBridge- PSCAD name
- Firing Pulse Generator for MMC Half Cell
- Category
- Other components
- Parameters
- 3, in 1 group
- Read from
- PSCAD 5.0.0, 2026-11-07
Read and write master:mmc_FiringHalfBridge in Python
import mhi.pscad
pscad = mhi.pscad.connect() # the PSCAD that is open; launch() starts one
project = pscad.project("my_case") # a case loaded in the workspace
for comp in project.find_all("master:mmc_FiringHalfBridge"): # the exact definition, namespace first
params = comp.parameters() # every parameter, as PSCAD holds it
print(str(params["DimFb"])) # Number of Cells per Arm
comp = project.find_all("master:mmc_FiringHalfBridge")[0]
comp.parameters(DimFb="20") # written as text
- A parameter is named exactly as in the table, letter case included:
parameters()gives every one of them in a dictionary, and a name the component does not have is refused. - A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (
str(...)) or the unit is lost. PSCAD keeps a written unit as it is given:"2500 [mohm]"stays in mohm. - A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
find_all()takes the exact definition only. A wildcard or a bare name withoutmaster:comes back empty; the Builder'spx_findwalks the pages for those.
The Builder's runtime does the same with the unit handled for you: px_get(comp, "DimFb") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.
Configuration
| Parameter | Unit | Default | Description |
|---|---|---|---|
ConfigChoice | · | BYPASS_TOP | ConfigurationWritten as BYPASS_BOTTOM (Bypass at Top), BYPASS_TOP (Bypass at Bottom) |
DimFbInteger | · | 10 | Number of Cells per ArmRange 2 to 10000 |
NameText | · | · | NameName for easy identificationRange 0 to 0 |
Related