master:mmc_FullCell parametersPSCAD MMC Full Cell

Every parameter of the PSCAD MMC Full Cell (master:mmc_FullCell): 10 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().

What master:mmc_FullCell is

MMC Full Cell, a component of PSCAD's Master Library, filed under other components.

Definition
master:mmc_FullCell
PSCAD name
MMC Full Cell
Category
Other components
Parameters
10, in 1 group; 5 carry a unit
Read from
PSCAD 5.0.0, 2026-11-07

Read and write master:mmc_FullCell in Python

import mhi.pscad

pscad = mhi.pscad.connect()              # the PSCAD that is open; launch() starts one
project = pscad.project("my_case")       # a case loaded in the workspace

for comp in project.find_all("master:mmc_FullCell"):   # the exact definition, namespace first
    params = comp.parameters()           # every parameter, as PSCAD holds it
    print(str(params["C"]))              # Capacitance per Sub-module, in uF

comp = project.find_all("master:mmc_FullCell")[0]
comp.parameters(C="1 [uF]")              # a value that carries a unit is written with it
  • A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
  • A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
  • A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
  • find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.

The Builder's runtime does the same with the unit handled for you: px_get(comp, "C") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.

Configuration

ParameterUnitDefaultDescription
CRealuF2000 [uF]Capacitance per Sub-module
DTBPChoice·NOEnable Partial Blocking?Select Yes or NoWritten as NO (No), YES (Yes)
DimCInteger·2Number of CellsRange 1 to 2147483647
NameText··NameName for easy identificationRange 0 to 0
R5Realohm1.0e8 [ohm]Capacitor Leakage Resistance
RIoffReal·0.0IGBT OFF ResistanceAt least 0
RIonReal·0.0IGBT ON ResistanceAt least 0
RoffRealohm1.0e6Diode OFF ResistanceAt least 0
RonRealohm0.01Diode ON ResistanceAt least 0
SumVc0RealkV0.0 [kV]Sum of Capacitor Voltages at Time ZeroAt least 0

Related