master:mmc_HalfCell parametersPSCAD MMC Half Cell
Every parameter of the PSCAD MMC Half Cell (master:mmc_HalfCell): 13 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().
What master:mmc_HalfCell is
MMC Half Cell, a component of PSCAD's Master Library, filed under other components.
- Definition
master:mmc_HalfCell- PSCAD name
- MMC Half Cell
- Category
- Other components
- Parameters
- 13, in 2 groups; 7 carry a unit
- Read from
- PSCAD 5.0.0, 2026-11-07
Read and write master:mmc_HalfCell in Python
import mhi.pscad
pscad = mhi.pscad.connect() # the PSCAD that is open; launch() starts one
project = pscad.project("my_case") # a case loaded in the workspace
for comp in project.find_all("master:mmc_HalfCell"): # the exact definition, namespace first
params = comp.parameters() # every parameter, as PSCAD holds it
print(str(params["C"])) # Capacitance per Sub-module, in uF
comp = project.find_all("master:mmc_HalfCell")[0]
comp.parameters(C="5000 [uF]") # a value that carries a unit is written with it
- A parameter is named exactly as in the table, letter case included:
parameters()gives every one of them in a dictionary, and a name the component does not have is refused. - A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (
str(...)) or the unit is lost. PSCAD keeps a written unit as it is given:"2500 [mohm]"stays in mohm. - A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
find_all()takes the exact definition only. A wildcard or a bare name withoutmaster:comes back empty; the Builder'spx_findwalks the pages for those.
The Builder's runtime does the same with the unit handled for you: px_get(comp, "C") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.
Converter Parameters
| Parameter | Unit | Default | Description |
|---|---|---|---|
CReal | uF | 2500 | Capacitance per Sub-moduleAt least 1 |
ConfigChoice | · | BYPASS_BOTTOM | ConfigurationChoose where bypass connection is: Top or BottomWritten as BYPASS_BOTTOM (Bypass at Top), BYPASS_TOP (Bypass at Bottom) |
DTBPChoice | · | NO | Enable Partial Blocking?Select Yes or NoWritten as NO (No), YES (Yes) |
DimInteger | · | 2 | Number of Equivalent Sub-modulesRange 2 to 2147483647 |
NameText | · | · | NameName for easy identificationRange 0 to 0 |
RDOFFReal | ohm | 10e6 | Diode OFF ResistanceRange 1000 to 100000000 |
RDONReal | ohm | 0.01 | Diode ON ResistanceRange 1E-06 to 1 |
RPReal | ohm | 10e6 | Capacitor Leakage Resistance |
RTOFFReal | ohm | 10e6 | IGBT OFF ResistanceRange 1000 to 100000000 |
RTONReal | ohm | 0.01 | IGBT ON ResistanceRange 1E-06 to 1 |
SumVc0Real | kV | 0.0 | Sum of Capacitor Voltages at tTme ZeroAt least 0 |
Monitoring
| Parameter | Unit | Default | Description |
|---|---|---|---|
CURText | · | · | Total Current Flowing ThroughRange 0 to 0 |
VdiffText | · | · | Voltage Across TerminalsRange 0 to 0 |
Related
← master:mmc_FullCell MMC Full Cell · master:pi-section pi-section →