master:rms3ph parametersPSCAD Three Phase RMS Meter

Every parameter of the PSCAD Three Phase RMS Meter (master:rms3ph): 8 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().

What master:rms3ph is

The three phase RMS meter, analog or digital, per-unitised on a rated voltage.

Definition
master:rms3ph
PSCAD name
Three Phase RMS Meter
Category
Meters and output
Parameters
8, in 1 group; 4 carry a unit
Read from
PSCAD 5.0.0, 2026-11-07

Most used master:rms3ph parameters

ParameterUnitDescription
ScalekVRated Voltage for Per-Unitizing (L-L,RMS)rated voltage for per-unitising
freqHzFundamental Frequencyfundamental frequency
Type·Meter Typeanalog or digital
TssSmoothing Time Constantsmoothing time constant

Read and write master:rms3ph in Python

import mhi.pscad

pscad = mhi.pscad.connect()              # the PSCAD that is open; launch() starts one
project = pscad.project("my_case")       # a case loaded in the workspace

for comp in project.find_all("master:rms3ph"):   # the exact definition, namespace first
    params = comp.parameters()           # every parameter, as PSCAD holds it
    print(str(params["Scale"]))          # Rated Voltage for Per-Unitizing (L-L,RMS), in kV

comp = project.find_all("master:rms3ph")[0]
comp.parameters(Scale="460 [kV]")        # a value that carries a unit is written with it
  • A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
  • A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
  • A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
  • find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.

The Builder's runtime does the same with the unit handled for you: px_get(comp, "Scale") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.

Configuration

ParameterUnitDefaultDescription
NSAMInteger·64Number of Samples in a CycleRange 8 to 256Used when Type==1
NameText··Name for IdentificationEnter a name for identification
ScaleRealkV230.0Rated Voltage for Per-Unitizing (L-L,RMS)At least 1E-38
TsReals0.02Smoothing Time ConstantAt least 0Used when Type==0
TypeChoice·ANALOGMeter TypeWritten as ANALOG (Analog), DIGITAL (Digital)
ViewChoice·SINGLE_LINEConnected to a Node Loop With:Written as 3_PHASE (3 Phase View), SINGLE_LINE (Single Line View)
VinitRealkV0.0Initial Voltage (L-L, RMS)At least 0Used when Type==1
freqRealHz60.0Fundamental FrequencyAt least 0Used when Type==1

Related

← master:rms-inst Single Phase RMS Meter · master:x_power_y X to the power of Y →