master:x_power_y parametersPSCAD X to the power of Y

Every parameter of the PSCAD X to the power of Y (master:x_power_y): 5 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().

What master:x_power_y is

X to the power of Y, a component of PSCAD's Master Library, filed under meters and output.

Definition
master:x_power_y
PSCAD name
X to the power of Y
Category
Meters and output
Parameters
5, in 1 group
Read from
PSCAD 5.0.0, 2026-11-07

Read and write master:x_power_y in Python

import mhi.pscad

pscad = mhi.pscad.connect()              # the PSCAD that is open; launch() starts one
project = pscad.project("my_case")       # a case loaded in the workspace

for comp in project.find_all("master:x_power_y"):   # the exact definition, namespace first
    params = comp.parameters()           # every parameter, as PSCAD holds it
    print(str(params["Dim"]))            # Dimension

comp = project.find_all("master:x_power_y")[0]
comp.parameters(Dim="2")                 # written as text
  • A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
  • A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
  • A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
  • find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.

The Builder's runtime does the same with the unit handled for you: px_get(comp, "Dim") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.

Configuraiton

ParameterUnitDefaultDescription
DPathChoice·REALData TypeWritten as REAL (Real), COMPLEX (Complex)
DimInteger·1DimensionRange 1 to 2147483647
NameText··Name for IdentificationEnter a name for identification
xnegChoice·00When x is Negative, OutputWritten as 00 (0.0), ABS_X_Y (|x|**y), NEG_ABS_X_Y (-|x|**y)Used when DPath!=2
yReal·1.0Power Y

Related

← master:rms3ph Three Phase RMS Meter · master:mux_array 12 Channel Multiplexer →