master:select parametersPSCAD Two Input Selector

Every parameter of the PSCAD Two Input Selector (master:select): 5 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().

What master:select is

Two Input Selector, a component of PSCAD's Master Library, filed under control blocks.

Definition
master:select
PSCAD name
Two Input Selector
Category
Control blocks
Parameters
5, in 1 group
Read from
PSCAD 5.0.0, 2026-11-07

Read and write master:select in Python

import mhi.pscad

pscad = mhi.pscad.connect()              # the PSCAD that is open; launch() starts one
project = pscad.project("my_case")       # a case loaded in the workspace

for comp in project.find_all("master:select"):   # the exact definition, namespace first
    params = comp.parameters()           # every parameter, as PSCAD holds it
    print(str(params["A"]))              # Channel A Selection Value

comp = project.find_all("master:select")[0]
comp.parameters(A="2")                   # written as text
  • A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
  • A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
  • A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
  • find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.

The Builder's runtime does the same with the unit handled for you: px_get(comp, "A") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.

Configuration

ParameterUnitDefaultDescription
AInteger·1Channel A Selection ValueWhen the control signal equal to this value, output will be equal to signal connected to channel ARange -2147483648 to 2147483647
COMText·SelectorFortran CommentOptional comment line to be placed in the generated code
DPathChoice·REALData Path Type:Choose Real, Integer or ComplexWritten as INTEGER (Integer), REAL (Real), COMPLEX (Complex)
DimInteger·1Dimension of signalsEnter the dimension of input signalsRange 1 to 2147483647
NameText··Name for IdentificationEnter a name for identification

Related