master:upramp parametersPSCAD Up Ramp Transfer Function
Every parameter of the PSCAD Up Ramp Transfer Function (master:upramp): 6 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().
What master:upramp is
Up Ramp Transfer Function, a component of PSCAD's Master Library, filed under control blocks.
- Definition
master:upramp- PSCAD name
- Up Ramp Transfer Function
- Category
- Control blocks
- Parameters
- 6, in 1 group
- Read from
- PSCAD 5.0.0, 2026-11-07
Read and write master:upramp in Python
import mhi.pscad
pscad = mhi.pscad.connect() # the PSCAD that is open; launch() starts one
project = pscad.project("my_case") # a case loaded in the workspace
for comp in project.find_all("master:upramp"): # the exact definition, namespace first
params = comp.parameters() # every parameter, as PSCAD holds it
print(str(params["Dim"])) # Dimension
comp = project.find_all("master:upramp")[0]
comp.parameters(Dim="2") # written as text
- A parameter is named exactly as in the table, letter case included:
parameters()gives every one of them in a dictionary, and a name the component does not have is refused. - A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (
str(...)) or the unit is lost. PSCAD keeps a written unit as it is given:"2500 [mohm]"stays in mohm. - A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
find_all()takes the exact definition only. A wildcard or a bare name withoutmaster:comes back empty; the Builder'spx_findwalks the pages for those.
The Builder's runtime does the same with the unit handled for you: px_get(comp, "Dim") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.
Configuration
| Parameter | Unit | Default | Description |
|---|---|---|---|
COMText | · | Up_Ramp_X-fer_Func | Fortran CommentOptional comment line written to the generated source code |
DimInteger | · | 1 | DimensionEnter the dimension of input/output signalsRange 1 to 2147483647 |
NameText | · | · | Name for IdentificationEnter a name for identification |
X1Real | · | 0.0 | Start of Ramp |
X2Real | · | 0.5 | Saturating Input |
Y2Real | · | 0.3 | Saturated Output |
Related
← master:select Two Input Selector · master:var_impedance Variable Series Impedance →