master:src_ccin_1 parametersPSCAD Current Source

Every parameter of the PSCAD Current Source (master:src_ccin_1): 6 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().

What master:src_ccin_1 is

Current Source, a component of PSCAD's Master Library, filed under sources.

Definition
master:src_ccin_1
PSCAD name
Current Source
Category
Sources
Parameters
6, in 2 groups; 4 carry a unit
Read from
PSCAD 5.0.0, 2026-11-07

Read and write master:src_ccin_1 in Python

import mhi.pscad

pscad = mhi.pscad.connect()              # the PSCAD that is open; launch() starts one
project = pscad.project("my_case")       # a case loaded in the workspace

for comp in project.find_all("master:src_ccin_1"):   # the exact definition, namespace first
    params = comp.parameters()           # every parameter, as PSCAD holds it
    print(str(params["Ph"]))             # Initial Phase, in deg

comp = project.find_all("master:src_ccin_1")[0]
comp.parameters(Ph="1 [deg]")            # a value that carries a unit is written with it
  • A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
  • A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
  • A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
  • find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.

The Builder's runtime does the same with the unit handled for you: px_get(comp, "Ph") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.

Configuration

ParameterUnitDefaultDescription
CntrlChoice·NOExternal ControlSelect Yes or NoWritten as NO (No), YES (Yes)
NameText··Source Name

Signal Parameters

ParameterUnitDefaultDescription
PhRealdeg0.0Initial PhaseRange -360 to 360Used when (Cntrl==0)
TcReals0.05Ramp up TimeAt least 0Used when (Cntrl==0)
VmRealkA132.79Magnitude (AC:L-G,RMS DC:Pk)At least 0Used when (Cntrl==0)
fRealHz60.0Frequency (0 for DC)At least 0Used when (Cntrl==0)

Related