master:src_current_dependent_current parametersPSCAD Current Dependent Current Source
Every parameter of the PSCAD Current Dependent Current Source (master:src_current_dependent_current): 3 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().
What master:src_current_dependent_current is
Current Dependent Current Source, a component of PSCAD's Master Library, filed under sources.
- Definition
master:src_current_dependent_current- PSCAD name
- Current Dependent Current Source
- Category
- Sources
- Parameters
- 3, in 1 group
- Read from
- PSCAD 5.0.0, 2026-11-07
Read and write master:src_current_dependent_current in Python
import mhi.pscad
pscad = mhi.pscad.connect() # the PSCAD that is open; launch() starts one
project = pscad.project("my_case") # a case loaded in the workspace
for comp in project.find_all("master:src_current_dependent_current"): # the exact definition, namespace first
params = comp.parameters() # every parameter, as PSCAD holds it
print(str(params["G_CDCS"])) # Scaling Factor
comp = project.find_all("master:src_current_dependent_current")[0]
comp.parameters(G_CDCS="2") # written as text
- A parameter is named exactly as in the table, letter case included:
parameters()gives every one of them in a dictionary, and a name the component does not have is refused. - A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (
str(...)) or the unit is lost. PSCAD keeps a written unit as it is given:"2500 [mohm]"stays in mohm. - A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
find_all()takes the exact definition only. A wildcard or a bare name withoutmaster:comes back empty; the Builder'spx_findwalks the pages for those.
The Builder's runtime does the same with the unit handled for you: px_get(comp, "G_CDCS") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.
General
| Parameter | Unit | Default | Description |
|---|---|---|---|
DimChoice | · | SINGLE | Single or Three PhaseSelect Single phase or Three phaseWritten as SINGLE (Single phase), THREE (Three phase) |
G_CDCSReal | · | 1.0 | Scaling FactorThe magnitude of the source current will be the measured current multiplied by this value. |
NameText | · | · | NameEnter a name for easy identificationRange 0 to 0 |
Related
← master:battery Battery · master:src_ccin_1 Current Source →