Every parameter of the PSCAD TSC/TCR Non-Linear Susceptance Characteristics (master:svcalloc1): 8 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().

What master:svcalloc1 is

TSC/TCR Non-Linear Susceptance Characteristics, a component of PSCAD's Master Library, filed under lines, cables and towers.

Definition
master:svcalloc1
PSCAD name
TSC/TCR Non-Linear Susceptance Characteristics
Category
Lines, cables and towers
Parameters
8, in 2 groups; 4 carry a unit
Read from
PSCAD 5.0.0, 2026-11-07

Read and write master:svcalloc1 in Python

import mhi.pscad

pscad = mhi.pscad.connect()              # the PSCAD that is open; launch() starts one
project = pscad.project("my_case")       # a case loaded in the workspace

for comp in project.find_all("master:svcalloc1"):   # the exact definition, namespace first
    params = comp.parameters()           # every parameter, as PSCAD holds it
    print(str(params["MTCR"]))           # Maximum Inductive MVAR, in MVAR

comp = project.find_all("master:svcalloc1")[0]
comp.parameters(MTCR="200 [MVAR]")       # a value that carries a unit is written with it
  • A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
  • A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
  • A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
  • find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.

The Builder's runtime does the same with the unit handled for you: px_get(comp, "MTCR") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.

Internal Output Variables

ParameterUnitDefaultDescription
BCText··Name for Susceptance of Single Capacitor Bank
BXlText··Name for Transformer Susceptance

Main Data

ParameterUnitDefaultDescription
MTCRRealMVAR100.0Maximum Inductive MVARAt least 1E-307
MTSCRealMVAR167.0Total MVAR of All Capacitor StagesAt least 1E-307
NCapInteger·2Total Number of Capacitor StagesRange 1 to 10
NameText··Name for IdentificationEnter a name for identification
TMVARealMVA200.0MVA of SVC TransformerAt least 0.001
XlpsRealpu0.17Transformer Leakage (primary-secondary)Range 1E-307 to 1

Related