tline_interface_v2 (V2 Style TLine Connection), a component of PSCAD's Master Library, filed under lines, cables and towers.
- Definition
master:tline_interface_v2- PSCAD name
- tline_interface_v2
- Category
- Lines, cables and towers
- Parameters
- 2, in 1 group
- Read from
- PSCAD 5.0.0, 2026-11-07
Read and write master:tline_interface_v2 in Python
import mhi.pscad
pscad = mhi.pscad.connect() # the PSCAD that is open; launch() starts one
project = pscad.project("my_case") # a case loaded in the workspace
for comp in project.find_all("master:tline_interface_v2"): # the exact definition, namespace first
params = comp.parameters() # every parameter, as PSCAD holds it
print(str(params["NC"])) # Number of conductors
comp = project.find_all("master:tline_interface_v2")[0]
comp.parameters(NC="3") # write one parameter
- A parameter is named exactly as in the table, letter case included:
parameters()gives every one of them in a dictionary, and a name the component does not have is refused. - A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (
str(...)) or the unit is lost. PSCAD keeps a written unit as it is given:"2500 [mohm]"stays in mohm. - A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
find_all()takes the exact definition only. A wildcard or a bare name withoutmaster:comes back empty; the Builder'spx_findwalks the pages for those.
The Builder's runtime does the same with the unit handled for you: px_get(comp, "NC") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.
Configuration
| Parameter | Unit | Default | Description |
|---|---|---|---|
NCChoice | · | 3 | Number of conductorsWritten as 1 = 1, 2 = 2, 3 = 3, 4 = 4, 5 = 5, 6 = 6, 7 = 7, 8 = 8, 9 = 9, 10 = 10 |
NameText | · | Tline | Name (match this with Tline info) |
Related