master:varrlc parametersPSCAD Variable R, L or C
Every parameter of the PSCAD Variable R, L or C (master:varrlc): 8 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().
What master:varrlc is
Variable R, L or C, a component of PSCAD's Master Library, filed under passive branches, loads and filters.
- Definition
master:varrlc- PSCAD name
- Variable R, L or C
- Category
- Passive branches, loads and filters
- Parameters
- 8, in 2 groups; 4 carry a unit
- Read from
- PSCAD 5.0.0, 2026-11-07
Read and write master:varrlc in Python
import mhi.pscad
pscad = mhi.pscad.connect() # the PSCAD that is open; launch() starts one
project = pscad.project("my_case") # a case loaded in the workspace
for comp in project.find_all("master:varrlc"): # the exact definition, namespace first
params = comp.parameters() # every parameter, as PSCAD holds it
print(str(params["C"])) # Capacitance, in uF
comp = project.find_all("master:varrlc")[0]
comp.parameters(C="2 [uF]") # a value that carries a unit is written with it
- A parameter is named exactly as in the table, letter case included:
parameters()gives every one of them in a dictionary, and a name the component does not have is refused. - A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (
str(...)) or the unit is lost. PSCAD keeps a written unit as it is given:"2500 [mohm]"stays in mohm. - A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
find_all()takes the exact definition only. A wildcard or a bare name withoutmaster:comes back empty; the Builder'spx_findwalks the pages for those.
The Builder's runtime does the same with the unit handled for you: px_get(comp, "C") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.
Configuration
| Parameter | Unit | Default | Description |
|---|---|---|---|
CReal | uF | 1.0 | CapacitanceAt least 0Used when (RLC==2) |
EReal | kV | 0.0 | Source Voltage ( may be 0.0 )At least 0 |
LReal | H | 1.0 | InductanceAt least 0Used when (RLC==1) |
NameText | · | · | Name for IdentificationEnter a name for identification |
RReal | ohm | 1.0 | ResistanceAt least 0Used when (RLC==0) |
RLCChoice | · | L | Branch Type:Written as R, L, C |
dLdCChoice | · | NO | Enable dL/dt or dC/dt EffectsWritten as NO (No), YES (Yes)Used when RLC!=0 |
Internal Outputs
| Parameter | Unit | Default | Description |
|---|---|---|---|
IText | · | · | Name for Branch Current [kA] |
Related
← master:filter Tuned Filter · master:voltmetergnd Voltmeter to Ground →