master:voltmetergnd parametersPSCAD Voltmeter to Ground
Every parameter of the PSCAD Voltmeter to Ground (master:voltmetergnd): 1 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().
What master:voltmetergnd is
Voltmeter to Ground (Voltmeter (Line - Ground)), a component of PSCAD's Master Library, filed under passive branches, loads and filters.
- Definition
master:voltmetergnd- PSCAD name
- Voltmeter to Ground
- Category
- Passive branches, loads and filters
- Parameters
- 1, in 1 group
- Read from
- PSCAD 5.0.0, 2026-11-07
Read and write master:voltmetergnd in Python
import mhi.pscad
pscad = mhi.pscad.connect() # the PSCAD that is open; launch() starts one
project = pscad.project("my_case") # a case loaded in the workspace
for comp in project.find_all("master:voltmetergnd"): # the exact definition, namespace first
params = comp.parameters() # every parameter, as PSCAD holds it
print(str(params["Name"])) # Signal Name
comp = project.find_all("master:voltmetergnd")[0]
comp.parameters(Name="F1") # write one parameter
- A parameter is named exactly as in the table, letter case included:
parameters()gives every one of them in a dictionary, and a name the component does not have is refused. - A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (
str(...)) or the unit is lost. PSCAD keeps a written unit as it is given:"2500 [mohm]"stays in mohm. - A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
find_all()takes the exact definition only. A wildcard or a bare name withoutmaster:comes back empty; the Builder'spx_findwalks the pages for those.
The Builder's runtime does the same with the unit handled for you: px_get(comp, "Name") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.
Configuration
| Parameter | Unit | Default | Description |
|---|---|---|---|
NameText | · | Ea | Signal Name |
Related
← master:varrlc Variable R, L or C · master:Dload_3branch Y connected configurable 3 branch load →