master:Yload parametersPSCAD Y connected configurable load

Every parameter of the PSCAD Y connected configurable load (master:Yload): 18 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().

What master:Yload is

Y connected configurable load (Individually configutable Y connected load), a component of PSCAD's Master Library, filed under passive branches, loads and filters.

Definition
master:Yload
PSCAD name
Y connected configurable load
Category
Passive branches, loads and filters
Parameters
18, in 1 group; 12 carry a unit
Read from
PSCAD 5.0.0, 2026-11-07

Read and write master:Yload in Python

import mhi.pscad

pscad = mhi.pscad.connect()              # the PSCAD that is open; launch() starts one
project = pscad.project("my_case")       # a case loaded in the workspace

for comp in project.find_all("master:Yload"):   # the exact definition, namespace first
    params = comp.parameters()           # every parameter, as PSCAD holds it
    print(str(params["Ca"]))             # Capacitance, in uF

comp = project.find_all("master:Yload")[0]
comp.parameters(Ca="2 [uF]")             # a value that carries a unit is written with it
  • A parameter is named exactly as in the table, letter case included: parameters() gives every one of them in a dictionary, and a name the component does not have is refused.
  • A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (str(...)) or the unit is lost. PSCAD keeps a written unit as it is given: "2500 [mohm]" stays in mohm.
  • A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
  • find_all() takes the exact definition only. A wildcard or a bare name without master: comes back empty; the Builder's px_find walks the pages for those.

The Builder's runtime does the same with the unit handled for you: px_get(comp, "Ca") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.

Configuration

ParameterUnitDefaultDescription
AChoice·RLCPhase A to Neutral BranchSelect Phase A to Neutral branch typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open)
BChoice·RLCPhase B to Neutral BranchSelect Phase B to Neutral branch typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open)
CChoice·RLCPhase C to Neutral BranchSelect Phase C to Neutral branch typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open)
CaRealuF1Capacitanceesistance of Phase A to NeutralAt least 1E-308Used when (A==3) || (A==5) || (A==6) || (A==7)
CbRealuF1Capacitanceesistance of Phase B to NeutralAt least 1E-308Used when (B==3) || (B==5) || (B==6) || (B==7)
CcRealuF1CapacitanceCapacitance of Phase C to NeutralAt least 1E-308Used when (C==3) || (C==5) || (C==6) || (C==7)
CnRealuF1CapacitanceCapacitance of Neutral to GroundAt least 1E-308Used when (N==3) || (N==5) || (N==6) || (N==7)
ExtNeutChoice·NOExternal Neutral ConnectionIf access to neutral needed, select YesWritten as NO (No), YES (Yes)
LaRealH0.1InductanceInductance of Phase A to NeutralAt least 1E-308Used when (A==2) || (A==4) || (A==6) || (A==7)
LbRealH0.1InductanceInductance of Phase B to NeutralAt least 1E-308Used when (B==2) || (B==4) || (B==6) || (B==7)
LcRealH0.1InductanceInductance of Phase C to NeutralAt least 1E-308Used when (C==2) || (C==4) || (C==6) || (C==7)
LnRealH0.1InductanceInductance of Neutral to GroundAt least 1E-308Used when (N==2) || (N==4) || (N==6) || (N==7)
NChoice·RLCNeutral to Ground BranchSelect Neutral to Groundl branch typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open)
NameText··NameThe name of the componentRange 0 to 0
RaRealohm1ResistanceResistance of Phase A to NeutralAt least 1E-308Used when (A==1) || (A==4) || (A==5) || (A==7)
RbRealohm1ResistanceResistance of Phase B to NeutralAt least 1E-308Used when (B==1) || (B==4) || (B==5) || (B==7)
RcRealohm1ResistanceResistance of Phase C to NeutralAt least 1E-308Used when (C==1) || (C==4) || (C==5) || (C==7)
RnRealohm1ResistanceResistance of Neutral to GroundAt least 1E-308Used when (N==1) || (N==4) || (N==5) || (N==7)

Related

← master:Yload_3branch Y connected configurable 3 branch load · master:xfmr-3p2w 3 Phase 2 Winding Transformer →