master:Yload_3branch parametersPSCAD Y connected configurable 3 branch load
Every parameter of the PSCAD Y connected configurable 3 branch load (master:Yload_3branch): 50 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().
What master:Yload_3branch is
Y connected configurable 3 branch load (Individually configutable Y connected 3 branch load), a component of PSCAD's Master Library, filed under passive branches, loads and filters.
- Definition
master:Yload_3branch- PSCAD name
- Y connected configurable 3 branch load
- Category
- Passive branches, loads and filters
- Parameters
- 50, in 5 groups; 36 carry a unit
- Read from
- PSCAD 5.0.0, 2026-11-07
Read and write master:Yload_3branch in Python
import mhi.pscad
pscad = mhi.pscad.connect() # the PSCAD that is open; launch() starts one
project = pscad.project("my_case") # a case loaded in the workspace
for comp in project.find_all("master:Yload_3branch"): # the exact definition, namespace first
params = comp.parameters() # every parameter, as PSCAD holds it
print(str(params["CaP1"])) # Capacitance, in uF
comp = project.find_all("master:Yload_3branch")[0]
comp.parameters(CaP1="2 [uF]") # a value that carries a unit is written with it
- A parameter is named exactly as in the table, letter case included:
parameters()gives every one of them in a dictionary, and a name the component does not have is refused. - A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (
str(...)) or the unit is lost. PSCAD keeps a written unit as it is given:"2500 [mohm]"stays in mohm. - A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
find_all()takes the exact definition only. A wildcard or a bare name withoutmaster:comes back empty; the Builder'spx_findwalks the pages for those.
The Builder's runtime does the same with the unit handled for you: px_get(comp, "CaP1") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.
- Configuration14
- Phase A to Neutral Branches9
- Phase B to Neutral Branches9
- Phase C to Neutral Branches9
- Neutral to Ground Branches9
Configuration
| Parameter | Unit | Default | Description |
|---|---|---|---|
AP1Choice | · | RLC | Phase A to Neutral Parallel Branch 1Select Phase A to Neutral parallel branch 1 typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open) |
AP2Choice | · | RLC | Phase A to Neutral Parallel Branch 2Select Phase A to Neutral parallel branch 2 typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open) |
ASChoice | · | RLC | Phase A to Neutral Series BranchSelect Phase A to Neutral series branch typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open) |
BP1Choice | · | RLC | Phase B to Neutral Parallel Branch 1Select Phase B to Neutral parallel branch 1 typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open) |
BP2Choice | · | RLC | Phase B to Neutral Parallel Branch 2Select Phase B to Neutral parallel branch 2 typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open) |
BSChoice | · | RLC | Phase B to Neutral Series BranchSelect Phase B to Neutral series branch typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open) |
CP1Choice | · | RLC | Phase C to Neutral Parallel Branch 1Select Phase C to Neutral parallel branch 1 typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open) |
CP2Choice | · | RLC | Phase C to Neutral Parallel Branch 2Select Phase C to Neutral parallel branch 2 typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open) |
CSChoice | · | RLC | Phase C to Neutral Series BranchSelect Phase C to Neutral series branch typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open) |
ExtNeutChoice | · | NO | External Neutral ConnectionIf access to neutral needed, select YesWritten as NO (No), YES (Yes) |
NP1Choice | · | RLC | Neutral to Ground Parallel Branch 1Select Neutral to Ground parallel branch 1 typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open) |
NP2Choice | · | RLC | Neutral to Ground Parallel Branch 2Select Neutral to Ground parallel branch 2 typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open) |
NSChoice | · | RLC | Neutral to Ground Series BranchSelect Neutral to Ground series branch typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open) |
NameText | · | · | NameThe name of the componentRange 0 to 0 |
Phase A to Neutral Branches
| Parameter | Unit | Default | Description |
|---|---|---|---|
CaP1Real | uF | 1 | CapacitanceCapacitance of Phase A to Neutral Parallel Branch 1At least 1E-308Used when ((AP1==3) || (AP1==5) || (AP1==6) || (AP1==7))&&(AP2!=0) |
CaP2Real | uF | 1 | CapacitanceCapacitance of Phase A to Neutral Parallel Branch 2At least 1E-308Used when ((AP2==3) || (AP2==5) || (AP2==6) || (AP2==7))&&(AP1!=0) |
CaSReal | uF | 1 | CapacitanceCapacitance of Phase A to Neutral Series BranchAt least 1E-308Used when (AS==3) || (AS==5) || (AS==6) || (AS==7) |
LaP1Real | H | 0.1 | InductanceInductance of Phase A to Neutral Parallel Branch 1At least 1E-308Used when ((AP1==2) || (AP1==4) || (AP1==6) || (AP1==7))&&(AP2!=0) |
LaP2Real | H | 0.1 | InductanceInductance of Phase A to Neutral Parallel Branch 2At least 1E-308Used when ((AP2==2) || (AP2==4) || (AP2==6) || (AP2==7))&&(AP1!=0) |
LaSReal | H | 0.1 | InductanceInductance of Phase A to Neutral Series BranchAt least 1E-308Used when (AS==2) || (AS==4) || (AS==6) || (AS==7) |
RaP1Real | ohm | 1 | ResistanceResistance of Phase A to Neutral Parallel Branch 1At least 1E-308Used when ((AP1==1) || (AP1==4) || (AP1==5) || (AP1==7))&&(AP2!=0) |
RaP2Real | ohm | 1 | ResistanceResistance of Phase A to Neutral Parallel Branch 2At least 1E-308Used when ((AP2==1) || (AP2==4) || (AP2==5) || (AP2==7))&&(AP1!=0) |
RaSReal | ohm | 1 | ResistanceResistance of Phase A to Neutral Series BranchAt least 1E-308Used when (AS==1) || (AS==4) || (AS==5) || (AS==7) |
Phase B to Neutral Branches
| Parameter | Unit | Default | Description |
|---|---|---|---|
CbP1Real | uF | 1 | CapacitanceCapacitance of Phase B to Neutral Parallel Branch 1At least 1E-308Used when ((BP1==3) || (BP1==5) || (BP1==6) || (BP1==7))&&(BP2!=0) |
CbP2Real | uF | 1 | CapacitanceCapacitance of Phase B to Neutral Parallel Branch 2At least 1E-308Used when ((BP2==3) || (BP2==5) || (BP2==6) || (BP2==7))&&(BP1!=0) |
CbSReal | uF | 1 | CapacitanceCapacitance of Phase B to Neutral Series BranchAt least 1E-308Used when (BS==3) || (BS==5) || (BS==6) || (BS==7) |
LbP1Real | H | 0.1 | InductanceInductance of Phase B to Neutral Parallel Branch 1At least 1E-308Used when ((BP1==2) || (BP1==4) || (BP1==6) || (BP1==7))&&(BP2!=0) |
LbP2Real | H | 0.1 | InductanceInductance of Phase B to Neutral Parallel Branch 2At least 1E-308Used when ((BP2==2) || (BP2==4) || (BP2==6) || (BP2==7))&&(BP1!=0) |
LbSReal | H | 0.1 | InductanceInductance of Phase B to Neutral Series BranchAt least 1E-308Used when (BS==2) || (BS==4) || (BS==6) || (BS==7) |
RbP1Real | ohm | 1 | ResistanceResistance of Phase B to Neutral Parallel Branch 1At least 1E-308Used when ((BP1==1) || (BP1==4) || (BP1==5) || (BP1==7))&&(BP2!=0) |
RbP2Real | ohm | 1 | ResistanceResistance of Phase B to Neutral Parallel Branch 2At least 1E-308Used when ((BP2==1) || (BP2==4) || (BP2==5) || (BP2==7))&&(BP1!=0) |
RbSReal | ohm | 1 | ResistanceResistance of Phase B to Neutral Series BranchAt least 1E-308Used when (BS==1) || (BS==4) || (BS==5) || (BS==7) |
Phase C to Neutral Branches
| Parameter | Unit | Default | Description |
|---|---|---|---|
CcP1Real | uF | 1 | CapacitanceCapacitance of Phase C to Neutral Parallel Branch 1At least 1E-308Used when ((CP1==3) || (CP1==5) || (CP1==6) || (CP1==7))&&(CP2!=0) |
CcP2Real | uF | 1 | CapacitanceCapacitance of Phase C to Neutral Parallel Branch 2At least 1E-308Used when ((CP2==3) || (CP2==5) || (CP2==6) || (CP2==7))&&(CP1!=0) |
CcSReal | uF | 1 | CapacitanceCapacitance of Phase C to Neutral Series BranchAt least 1E-308Used when (CS==3) || (CS==5) || (CS==6) || (CS==7) |
LcP1Real | H | 0.1 | InductanceInductance of Phase C to Neutral Parallel Branch 1At least 1E-308Used when ((CP1==2) || (CP1==4) || (CP1==6) || (CP1==7))&&(CP2!=0) |
LcP2Real | H | 0.1 | InductanceInductance of Phase C to Neutral Parallel Branch 2At least 1E-308Used when ((CP2==2) || (CP2==4) || (CP2==6) || (CP2==7))&&(CP1!=0) |
LcSReal | H | 0.1 | InductanceInductance of Phase C to Neutral Series BranchAt least 1E-308Used when (CS==2) || (CS==4) || (CS==6) || (CS==7) |
RcP1Real | ohm | 1 | ResistanceResistance of Phase C to Neutral Parallel Branch 1At least 1E-308Used when ((CP1==1) || (CP1==4) || (CP1==5) || (CP1==7))&&(CP2!=0) |
RcP2Real | ohm | 1 | ResistanceResistance of Phase C to Neutral Parallel Branch 2At least 1E-308Used when ((CP2==1) || (CP2==4) || (CP2==5) || (CP2==7))&&(CP1!=0) |
RcSReal | ohm | 1 | ResistanceResistance of Phase C to Neutral Series BranchAt least 1E-308Used when (CS==1) || (CS==4) || (CS==5) || (CS==7) |
Neutral to Ground Branches
| Parameter | Unit | Default | Description |
|---|---|---|---|
CnP1Real | uF | 1 | CapacitanceCapacitance of Neutral to Ground Parallel Branch 1At least 1E-308Used when ((NP1==3) || (NP1==5) || (NP1==6) || (NP1==7))&&(NP2!=0) |
CnP2Real | uF | 1 | CapacitanceCapacitance of Neutral to Ground Parallel Branch 2At least 1E-308Used when ((NP2==3) || (NP2==5) || (NP2==6) || (NP2==7))&&(NP1!=0) |
CnSReal | uF | 1 | CapacitanceCapacitance of Neutral to Ground Series BranchAt least 1E-308Used when (NS==3) || (NS==5) || (NS==6) || (NS==7) |
LnP1Real | H | 0.1 | InductanceInductance of Neutral to Ground Parallel Branch 1At least 1E-308Used when ((NP1==2) || (NP1==4) || (NP1==6) || (NP1==7))&&(NP2!=0) |
LnP2Real | H | 0.1 | InductanceInductance of Neutral to Ground Parallel Branch 2At least 1E-308Used when ((NP2==2) || (NP2==4) || (NP2==6) || (NP2==7))&&(NP1!=0) |
LnSReal | H | 0.1 | InductanceInductance of Neutral to Ground Series BranchAt least 1E-308Used when (NS==2) || (NS==4) || (NS==6) || (NS==7) |
RnP1Real | ohm | 1 | ResistanceResistance of Neutral to Ground Parallel Branch 1At least 1E-308Used when ((NP1==1) || (NP1==4) || (NP1==5) || (NP1==7))&&(NP2!=0) |
RnP2Real | ohm | 1 | ResistanceResistance of Neutral to Ground Parallel Branch 2At least 1E-308Used when ((NP2==1) || (NP2==4) || (NP2==5) || (NP2==7))&&(NP1!=0) |
RnSReal | ohm | 1 | ResistanceResistance of Neutral to Ground Series BranchAt least 1E-308Used when (NS==1) || (NS==4) || (NS==5) || (NS==7) |