master:Dload_3branch parametersPSCAD Y connected configurable 3 branch load
Every parameter of the PSCAD Y connected configurable 3 branch load (master:Dload_3branch): 37 names, with the unit, the default and the meaning PSCAD gives each one. Copy a name into parameters().
What master:Dload_3branch is
Y connected configurable 3 branch load (Individually configutable Delta connected 3 branch load), a component of PSCAD's Master Library, filed under passive branches, loads and filters.
- Definition
master:Dload_3branch- PSCAD name
- Y connected configurable 3 branch load
- Category
- Passive branches, loads and filters
- Parameters
- 37, in 4 groups; 27 carry a unit
- Read from
- PSCAD 5.0.0, 2026-11-07
Read and write master:Dload_3branch in Python
import mhi.pscad
pscad = mhi.pscad.connect() # the PSCAD that is open; launch() starts one
project = pscad.project("my_case") # a case loaded in the workspace
for comp in project.find_all("master:Dload_3branch"): # the exact definition, namespace first
params = comp.parameters() # every parameter, as PSCAD holds it
print(str(params["CabP1"])) # Capacitance, in uF
comp = project.find_all("master:Dload_3branch")[0]
comp.parameters(CabP1="2 [uF]") # a value that carries a unit is written with it
- A parameter is named exactly as in the table, letter case included:
parameters()gives every one of them in a dictionary, and a name the component does not have is refused. - A value that carries a unit comes back as a number whose unit is only in its text, so read it as text first (
str(...)) or the unit is lost. PSCAD keeps a written unit as it is given:"2500 [mohm]"stays in mohm. - A Choice is read and written as its symbol (the capitals in "Written as"), not as the words PSCAD shows in the dialog.
find_all()takes the exact definition only. A wildcard or a bare name withoutmaster:comes back empty; the Builder'spx_findwalks the pages for those.
The Builder's runtime does the same with the unit handled for you: px_get(comp, "CabP1") and px_set(...), which also records the old value so the case is put back at the end. Getting started shows them.
Configuration
| Parameter | Unit | Default | Description |
|---|---|---|---|
ABP1Choice | · | RLC | Phase A to Phase B Parallel Branch 1Select Phase A to Phase B parallel branch 1 typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open) |
ABP2Choice | · | RLC | Phase A to Phase B Parallel Branch 2Select Phase A to Phase B parallel branch 2 typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open) |
ABSChoice | · | RLC | Phase A to Phase B Series BranchSelect Phase A to Phase B series branch typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open) |
BCP1Choice | · | RLC | Phase B to Phase C Parallel Branch 1Select Phase B to Phase C parallel branch 1 typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open) |
BCP2Choice | · | RLC | Phase B to Phase C Parallel Branch 2Select Phase B to Phase C parallel branch 2 typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open) |
BCSChoice | · | RLC | Phase B to Phase C Series BranchSelect Phase B to Phase C series branch typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open) |
CAP1Choice | · | RLC | Phase C to Phase A Parallel Branch 1Select Phase C to Phase A parallel branch 1 typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open) |
CAP2Choice | · | RLC | Phase C to Phase A Parallel Branch 2Select Phase C to Phase A parallel branch 2 typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open) |
CASChoice | · | RLC | Phase C to Phase A Series BranchSelect Phase C to Phase A series branch typeWritten as SHORT (Short), R, L, C, RL, RC, LC, RLC, OPEN (Open) |
NameText | · | · | NameThe name of the componentRange 0 to 0 |
Phase A to Phase B Branches
| Parameter | Unit | Default | Description |
|---|---|---|---|
CabP1Real | uF | 1 | CapacitanceCapacitance of Phase A to Phase B Parallel Branch 1At least 1E-308Used when ((ABP1==3) || (ABP1==5) || (ABP1==6) || (ABP1==7))&&(ABP2!=0) |
CabP2Real | uF | 1 | CapacitanceCapacitance of Phase A to Phase B Parallel Branch 2At least 1E-308Used when ((ABP2==3) || (ABP2==5) || (ABP2==6) || (ABP2==7))&&(ABP1!=0) |
CabSReal | uF | 1 | CapacitanceCapacitance of Phase A to Phase B Series BranchAt least 1E-308Used when (ABS==3) || (ABS==5) || (ABS==6) || (ABS==7) |
LabP1Real | H | 0.1 | InductanceInductance of Phase A to Phase B Parallel Branch 1At least 1E-308Used when ((ABP1==2) || (ABP1==4) || (ABP1==6) || (ABP1==7))&&(ABP2!=0) |
LabP2Real | H | 0.1 | InductanceInductance of Phase A to Phase B Parallel Branch 2At least 1E-308Used when ((ABP2==2) || (ABP2==4) || (ABP2==6) || (ABP2==7))&&(ABP1!=0) |
LabSReal | H | 0.1 | InductanceInductance of Phase A to Phase B Series BranchAt least 1E-308Used when (ABS==2) || (ABS==4) || (ABS==6) || (ABS==7) |
RabP1Real | ohm | 1 | ResistanceResistance of Phase A to Phase B Parallel Branch 1At least 1E-308Used when ((ABP1==1) || (ABP1==4) || (ABP1==5) || (ABP1==7))&&(ABP2!=0) |
RabP2Real | ohm | 1 | ResistanceResistance of Phase A to Phase B Parallel Branch 2At least 1E-308Used when ((ABP2==1) || (ABP2==4) || (ABP2==5) || (ABP2==7))&&(ABP1!=0) |
RabSReal | ohm | 1 | ResistanceResistance of Phase A to Phase B Series BranchAt least 1E-308Used when (ABS==1) || (ABS==4) || (ABS==5) || (ABS==7) |
Phase B to Phase C Branches
| Parameter | Unit | Default | Description |
|---|---|---|---|
CbcP1Real | uF | 1 | CapacitanceCapacitance of Phase B to Phase C Parallel Branch 1At least 1E-308Used when ((BCP1==3) || (BCP1==5) || (BCP1==6) || (BCP1==7))&&(BCP2!=0) |
CbcP2Real | uF | 1 | CapacitanceCapacitance of Phase B to Phase C Parallel Branch 2At least 1E-308Used when ((BCP2==3) || (BCP2==5) || (BCP2==6) || (BCP2==7))&&(BCP1!=0) |
CbcSReal | uF | 1 | CapacitanceCapacitance of Phase B to Phase C Series BranchAt least 1E-308Used when (BCS==3) || (BCS==5) || (BCS==6) || (BCS==7) |
LbcP1Real | H | 0.1 | InductanceInductance of Phase B to Phase C Parallel Branch 1At least 1E-308Used when ((BCP1==2) || (BCP1==4) || (BCP1==6) || (BCP1==7))&&(BCP2!=0) |
LbcP2Real | H | 0.1 | InductanceInductance of Phase B to Phase C Parallel Branch 2At least 1E-308Used when ((BCP2==2) || (BCP2==4) || (BCP2==6) || (BCP2==7))&&(BCP1!=0) |
LbcSReal | H | 0.1 | InductanceInductance of Phase B to Phase C Series BranchAt least 1E-308Used when (BCS==2) || (BCS==4) || (BCS==6) || (BCS==7) |
RbcP1Real | ohm | 1 | ResistanceResistance of Phase B to Phase C Parallel Branch 1At least 1E-308Used when ((BCP1==1) || (BCP1==4) || (BCP1==5) || (BCP1==7))&&(BCP2!=0) |
RbcP2Real | ohm | 1 | ResistanceResistance of Phase B to Phase C Parallel Branch 2At least 1E-308Used when ((BCP2==1) || (BCP2==4) || (BCP2==5) || (BCP2==7))&&(BCP1!=0) |
RbcSReal | ohm | 1 | ResistanceResistance of Phase B to Phase C Series BranchAt least 1E-308Used when (BCS==1) || (BCS==4) || (BCS==5) || (BCS==7) |
Phase C to Phase A Branches
| Parameter | Unit | Default | Description |
|---|---|---|---|
CcaP1Real | uF | 1 | CapacitanceCapacitance of Phase C to Phase A Parallel Branch 1At least 1E-308Used when ((CAP1==3) || (CAP1==5) || (CAP1==6) || (CAP1==7))&&(CAP2!=0) |
CcaP2Real | uF | 1 | CapacitanceCapacitance of Phase C to Phase A Parallel Branch 2At least 1E-308Used when ((CAP2==3) || (CAP2==5) || (CAP2==6) || (CAP2==7))&&(CAP1!=0) |
CcaSReal | uF | 1 | CapacitanceCapacitance of Phase C to Phase A Series BranchAt least 1E-308Used when (CAS==3) || (CAS==5) || (CAS==6) || (CAS==7) |
LcaP1Real | H | 0.1 | InductanceInductance of Phase C to Phase A Parallel Branch 1At least 1E-308Used when ((CAP1==2) || (CAP1==4) || (CAP1==6) || (CAP1==7))&&(CAP2!=0) |
LcaP2Real | H | 0.1 | InductanceInductance of Phase C to Phase A Parallel Branch 2At least 1E-308Used when ((CAP2==2) || (CAP2==4) || (CAP2==6) || (CAP2==7))&&(CAP1!=0) |
LcaSReal | H | 0.1 | InductanceInductance of Phase C to Phase A Series BranchAt least 1E-308Used when (CAS==2) || (CAS==4) || (CAS==6) || (CAS==7) |
RcaP1Real | ohm | 1 | ResistanceResistance of Phase C to Phase A Parallel Branch 1At least 1E-308Used when ((CAP1==1) || (CAP1==4) || (CAP1==5) || (CAP1==7))&&(CAP2!=0) |
RcaP2Real | ohm | 1 | ResistanceResistance of Phase C to Phase A Parallel Branch 2At least 1E-308Used when ((CAP2==1) || (CAP2==4) || (CAP2==5) || (CAP2==7))&&(CAP1!=0) |
RcaSReal | ohm | 1 | ResistanceResistance of Phase C to Phase A Series BranchAt least 1E-308Used when (CAS==1) || (CAS==4) || (CAS==5) || (CAS==7) |